Monitoring local cell viability in engineered tissues: a fast, quantitative, and nondestructive approach.

Assessment of cell viability is a key issue in monitoring in vitro engineered tissue constructs. In this study we describe a fully automated, quantitative, and nondestructive approach, which is particularly suitable for tissue engineering. The approach offers several advantages above existing methods. Living and dead cell numbers can be separately determined for both isolated cells and cells that form networks during tissue formation. Moreover, viability can be locally monitored in time throughout the three-dimensional tissue. The viability assay is based on a dual fluorescent staining technique using CellTracker Green (CTG) for detection of living cells and propidium iodide (PI) for dead cells. CTG and PI images are created with a confocal laser scanning microscope. To determine the number of living cells, CTG fluorescence intensity is determined from the CTG image. Thereby, novel image-processing techniques have been developed, normalizing for various undesired influences that alter measurements of absolute CTG fluorescence intensities. Dead cell numbers are determined from the PI image, using an improved computerized counting method. The approach was first evaluated on C2C12 monolayers, of which images were taken directly after probe addition and 24 h later. Results show that at both times, computed living and dead cell numbers highly correlate with manually counted cell numbers (r > 0.996). Next, the approach was applied for monitoring viability in three-dimensional engineered skeletal muscle tissue constructs, which were subjected to unfavorable environmental conditions. This example illustrated that local viability can be quantitatively, nondestructively, and locally monitored in three-dimensional tissue constructs, making it a promising tool in the field of tissue engineering.

[1]  T. Mosmann Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. , 1983, Journal of immunological methods.

[2]  Cwj Cees Oomens,et al.  Quantification and localisation of damage in rat muscles after controlled loading; a new approach to study the aetiology of pressure sores. , 2001, Medical engineering & physics.

[3]  C. Oomens,et al.  Evaluation of a Continuous Quantification Method of Apoptosis and Necrosis in Tissue Cultures , 2004, Cytotechnology.

[4]  R. T. Proffitt,et al.  A fluorescence digital image microscopy system for quantifying relative cell numbers in tissue culture plates. , 1996, Cytometry.

[5]  A. Meunier,et al.  In vivo tracking of bone marrow fibroblasts with fluorescent carbocyanine dye. , 2001, Journal of biomedical materials research.

[6]  D. A. Lee,et al.  Compressive Deformation and Damage of Muscle Cell Subpopulations in a Model System , 2001, Annals of Biomedical Engineering.

[7]  I. Beletsky,et al.  A new assay for cell death. , 1990, Journal of immunological methods.

[8]  K. Wolff,et al.  A standardized, a computer-assisted in vitro assay for the assessment of neutrophil transmigration across endothelial monolayers. , 1999, JIM - Journal of Immunological Methods.

[9]  K H Jones,et al.  An improved method to determine cell viability by simultaneous staining with fluorescein diacetate-propidium iodide. , 1985, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[10]  D. Leckband,et al.  Structural and functional optical imaging of three-dimensional engineered tissue development. , 2004, Tissue engineering.

[11]  G. J. Brakenhoff,et al.  Refractive index and axial distance measurements in 3-D microscopy , 1992 .

[12]  Michael J. Maher,et al.  Statistics for Technology. , 1979 .

[13]  R J Errington,et al.  Four-dimensional imaging of living chondrocytes in cartilage using confocal microscopy: a pragmatic approach. , 1997, The American journal of physiology.

[14]  Mark D. Fricker,et al.  Aberration control in quantitative imaging of botanical specimens by multidimensional fluorescence microscopy , 1996 .

[15]  H. Suh,et al.  Viability evaluation of engineered tissues. , 2000, Yonsei medical journal.

[16]  P. Cochard,et al.  Dual staining assessment of Schwann cell viability within whole peripheral nerves using calcein-AM and ethidium homodimer , 1997, Journal of Neuroscience Methods.

[17]  G W Plant,et al.  Neural tissue engineering: from polymer to biohybrid organs. , 1996, Biomaterials.

[18]  T Lindmo,et al.  Flow cytometry: a high-resolution instrument for everyone. , 1979, Science.

[19]  Cwj Cees Oomens,et al.  Mechanical and failure properties of single attached cells under compression. , 2005, Journal of biomechanics.

[20]  H. Vandenburgh,et al.  A simplified method for tissue engineering skeletal muscle organoids in vitro , 1997, In Vitro Cellular & Developmental Biology - Animal.

[21]  H. Vandenburgh,et al.  Organogenesis of skeletal muscle in tissue culture. , 1999, Methods in molecular medicine.

[22]  S. Hell,et al.  Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index , 1993 .

[23]  Cees W J Oomens,et al.  In vitro models to study compressive strain-induced muscle cell damage. , 2003, Biorheology.

[24]  C. D. Nelson,et al.  Automated image analysis of live/dead staining of the fungus Aureobasidium pullulans on microscope slides and leaf surfaces. , 2000, BioTechniques.

[25]  Kjell Carlsson,et al.  The influence of specimen refractive index, detector signal integration, and non‐uniform scan speed on the imaging properties in confocal microscopy , 1991 .

[26]  H. Vandenburgh,et al.  Tissue-engineered skeletal muscle organoids for reversible gene therapy. , 1996, Human gene therapy.