Development and analysis of novel soft-starter/energy-saver topology for delta-connected induction motors
暂无分享,去创建一个
[1] Gunnar J. Berg,et al. Transient Analysis of Three-Phase SCR Controlled Induction Motors , 1981, IEEE Transactions on Industry Applications.
[2] Thomas A. Lipo,et al. A Quantitative Analysis of Induction Motor Performance Improvement by SCR Voltage Control , 1983 .
[3] V. V. Sastry,et al. Optimal soft starting of voltage-controller-fed IM drive based on voltage across thyristor , 1997 .
[4] Frank M. Bruce,et al. Reduced-Voltage Starting of Squirrel-Cage Induction Motors , 1984, IEEE Transactions on Industry Applications.
[5] Paul C. Krause,et al. Analysis of electric machinery , 1987 .
[6] N. Mohan. Improvement in Energy Efficiency of Induction Motors by Means of Voltage Control , 1980, IEEE Transactions on Power Apparatus and Systems.
[7] G. Berg,et al. Steady State Performance Analysis of SCR Controlled Induction Motors: A Closed Form Solution , 1984, IEEE Transactions on Power Apparatus and Systems.
[8] S. Murthy,et al. A New Approach to Dynamic Modeling and Transisent Analysis of SCR-Controlled Induction Motors , 1982, IEEE Transactions on Power Apparatus and Systems.
[9] Muammer Ermis,et al. A solid state direct on line starter for medium voltage induction motors with minimized current and torque pulsations , 1999 .
[10] Kaushik Rajashekara,et al. A neuro-fuzzy-based on-line efficiency optimization control of a stator flux-oriented direct vector-controlled induction motor drive , 1997, IEEE Trans. Ind. Electron..
[11] Muammer Ermis,et al. Soft starting of large induction motors at constant current with minimised starting torque pulsations , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).
[12] John Htsui. Magnitude, Amplitudes and Frequencies of Induction-Motor Air-Gap Transient Torque Through Simultaneous Reclosing with or Without Capacitors , 1985, IEEE Transactions on Power Apparatus and Systems.
[13] A. A. Shaltout,et al. Analysis of torsional torques in starting of large squirrel cage induction motors , 1994 .
[14] H. G. Tempelaar,et al. Determination of transient overvoltages caused by switching of high voltage motors , 1988 .
[15] R. F. McElveen,et al. Starting high-inertia loads , 2001 .
[16] B. J. Chalmers,et al. Analysis of variable-voltage thyristor controlled induction motors , 1990 .
[17] W. S. Wood,et al. Transient torques in induction motors, due to switching of the supply , 1965 .
[18] D. F. Binns. Comparative costs of energy losses in induction motors , 1987 .
[19] W. Deleroi,et al. Analysis and application of three-phase induction motor voltage controller with improved transient performance , 1989 .
[20] P. Malkin,et al. Solid-state medium voltage contactor , 1993 .
[21] R. Daugherty. Analysis of Transient Electrical Torques and Shaft Toruqes in Induction Motors as a Result of Power Supply Disturbances , 1982, IEEE Transactions on Power Apparatus and Systems.
[22] Thomas A. Lipo. The Analysis of Induction Motors with Voltage Control by Symmetrically Triggered Thyristors , 1971 .
[23] T. S. Lauber,et al. Prestriking voltages associated with motor breaker closing , 1988 .
[24] W. Shepherd. On the Analysis of the Three-Phase Induction Motor with Voltage Control by Thyristor Switching , 1968 .
[25] Donald W. Novotny,et al. An Equivalent-Circuit Model for Phase-Back Voltage Control of AC Machines , 1986, IEEE Transactions on Industry Applications.
[26] Jack Bowerfind,et al. Application of Solid-State AC Motor Starters in the Pulp and Paper Industry , 1986, IEEE Transactions on Industry Applications.
[27] Patrick J. Colleran,et al. Controlled Starting of AC Induction Motors , 1983, IEEE Transactions on Industry Applications.
[28] Bimal K. Bose,et al. Power Electronics and Ac Drives , 1986 .
[29] D. Novotny,et al. Characteristic Induction Motor Slip Values for Variable Voltage Part Load Performance Optimization , 1983, IEEE Power Engineering Review.
[30] Frede Blaabjerg,et al. Can soft-starters help save energy? , 1997 .