Development and analysis of novel soft-starter/energy-saver topology for delta-connected induction motors

A thyristorised star/delta switch is proposed as a soft starter and energy saver for delta-connected induction motor drives. A low-cost microprocessor-based hardware is developed and used for the control of the star/delta switch. The use of the star/delta switch for starting is first explained followed by its application as an energy saver. Three schemes of switching transitions are proposed and implemented for the star (delta) to delta (star) changeover process. Extensive simulation and experimental results are presented to show that the proposed circuit is a promising candidate as a starter/energy saver for delta-connected induction motor drives.

[1]  Gunnar J. Berg,et al.  Transient Analysis of Three-Phase SCR Controlled Induction Motors , 1981, IEEE Transactions on Industry Applications.

[2]  Thomas A. Lipo,et al.  A Quantitative Analysis of Induction Motor Performance Improvement by SCR Voltage Control , 1983 .

[3]  V. V. Sastry,et al.  Optimal soft starting of voltage-controller-fed IM drive based on voltage across thyristor , 1997 .

[4]  Frank M. Bruce,et al.  Reduced-Voltage Starting of Squirrel-Cage Induction Motors , 1984, IEEE Transactions on Industry Applications.

[5]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[6]  N. Mohan Improvement in Energy Efficiency of Induction Motors by Means of Voltage Control , 1980, IEEE Transactions on Power Apparatus and Systems.

[7]  G. Berg,et al.  Steady State Performance Analysis of SCR Controlled Induction Motors: A Closed Form Solution , 1984, IEEE Transactions on Power Apparatus and Systems.

[8]  S. Murthy,et al.  A New Approach to Dynamic Modeling and Transisent Analysis of SCR-Controlled Induction Motors , 1982, IEEE Transactions on Power Apparatus and Systems.

[9]  Muammer Ermis,et al.  A solid state direct on line starter for medium voltage induction motors with minimized current and torque pulsations , 1999 .

[10]  Kaushik Rajashekara,et al.  A neuro-fuzzy-based on-line efficiency optimization control of a stator flux-oriented direct vector-controlled induction motor drive , 1997, IEEE Trans. Ind. Electron..

[11]  Muammer Ermis,et al.  Soft starting of large induction motors at constant current with minimised starting torque pulsations , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[12]  John Htsui Magnitude, Amplitudes and Frequencies of Induction-Motor Air-Gap Transient Torque Through Simultaneous Reclosing with or Without Capacitors , 1985, IEEE Transactions on Power Apparatus and Systems.

[13]  A. A. Shaltout,et al.  Analysis of torsional torques in starting of large squirrel cage induction motors , 1994 .

[14]  H. G. Tempelaar,et al.  Determination of transient overvoltages caused by switching of high voltage motors , 1988 .

[15]  R. F. McElveen,et al.  Starting high-inertia loads , 2001 .

[16]  B. J. Chalmers,et al.  Analysis of variable-voltage thyristor controlled induction motors , 1990 .

[17]  W. S. Wood,et al.  Transient torques in induction motors, due to switching of the supply , 1965 .

[18]  D. F. Binns Comparative costs of energy losses in induction motors , 1987 .

[19]  W. Deleroi,et al.  Analysis and application of three-phase induction motor voltage controller with improved transient performance , 1989 .

[20]  P. Malkin,et al.  Solid-state medium voltage contactor , 1993 .

[21]  R. Daugherty Analysis of Transient Electrical Torques and Shaft Toruqes in Induction Motors as a Result of Power Supply Disturbances , 1982, IEEE Transactions on Power Apparatus and Systems.

[22]  Thomas A. Lipo The Analysis of Induction Motors with Voltage Control by Symmetrically Triggered Thyristors , 1971 .

[23]  T. S. Lauber,et al.  Prestriking voltages associated with motor breaker closing , 1988 .

[24]  W. Shepherd On the Analysis of the Three-Phase Induction Motor with Voltage Control by Thyristor Switching , 1968 .

[25]  Donald W. Novotny,et al.  An Equivalent-Circuit Model for Phase-Back Voltage Control of AC Machines , 1986, IEEE Transactions on Industry Applications.

[26]  Jack Bowerfind,et al.  Application of Solid-State AC Motor Starters in the Pulp and Paper Industry , 1986, IEEE Transactions on Industry Applications.

[27]  Patrick J. Colleran,et al.  Controlled Starting of AC Induction Motors , 1983, IEEE Transactions on Industry Applications.

[28]  Bimal K. Bose,et al.  Power Electronics and Ac Drives , 1986 .

[29]  D. Novotny,et al.  Characteristic Induction Motor Slip Values for Variable Voltage Part Load Performance Optimization , 1983, IEEE Power Engineering Review.

[30]  Frede Blaabjerg,et al.  Can soft-starters help save energy? , 1997 .