Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation.

OBJECTIVES We sought to compare 3 methods of measurements of the aortic annulus, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT), and to evaluate their potential clinical impact on transcatheter aortic valve implantation (TAVI) strategy. BACKGROUND Exact measurement of the aortic annulus is critical for a patient's selection and successful implantation. METHODS Annulus diameter was measured using TTE, TEE, and MSCT in 45 consecutive patients with severe aortic stenosis referred for TAVI. The TAVI strategy (decision to implant and choice of the prosthesis' size) was based on manufacturer's recommendations (Edwards-Sapien prosthesis, Edwards Lifesciences, Inc., Irvine, California). RESULTS Correlations between methods were good but the difference between MSCT and TTE (1.22 +/- 1.3 mm) or TEE (1.52 +/- 1.1 mm) was larger than the difference between TTE and TEE (0.6 +/- 0.8 mm; p = 0.03 and p < 0.0001, respectively). Regarding TAVI strategy, agreement between TTE and TEE overall was good (kappa = 0.68), but TAVI strategy would have been different in 8 patients (17%). Agreement between MSCT and TTE or TEE was only modest (kappa = 0.28 and 0.27), and a decision based on MSCT measurements would have modified the TAVI strategy in a large number of patients (40% to 42%). Implantation, performed in 34 patients (76%) based on TEE measurements, was successful in all but 1 patient with grade 3/4 regurgitation. CONCLUSIONS In patients referred for TAVI, measurements of the aortic annulus using TTE, TEE, and MSCT were close but not identical, and the method used has important potential clinical implications on TAVI strategy. In the absence of a gold standard, a strategy based on TEE measurements provided good clinical results.

[1]  R. Levine,et al.  Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  J. Gardin,et al.  Burden of valvular heart diseases: a population-based study , 2006, The Lancet.

[3]  M. Enriquez-Sarano,et al.  Evaluation and Clinical Implications of Aortic Valve Calcification Measured by Electron-Beam Computed Tomography , 2004, Circulation.

[4]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[5]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[6]  F. Laurent,et al.  Predictive value of noninvasive coronary angiography with multidetector computed tomography to detect significant coronary stenosis before valve surgery. , 2006, The American journal of cardiology.

[7]  Volkmar Falk,et al.  Minimally invasive transapical beating heart aortic valve implantation--proof of concept. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[8]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[9]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[10]  A. Cohen-Solal,et al.  Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. , 2006, European heart journal.

[11]  Assaf Bash,et al.  Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. , 2004, Journal of the American College of Cardiology.

[12]  Y. Castier,et al.  Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly. , 2008, European heart journal.

[13]  Mirko Doss,et al.  Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience , 2007, Circulation.

[14]  Paul Schoenhagen,et al.  Aortic root morphology in patients undergoing percutaneous aortic valve replacement: evidence of aortic root remodeling. , 2009, The Journal of thoracic and cardiovascular surgery.

[15]  V. Addonizio,et al.  Prediction of Homograft Aortic Valve Size by Transthoracic and Transesophageal Two‐Dimensional Echocardiography , 1997, Echocardiography.

[16]  N. Al-Attar,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European heart journal.

[17]  Jean-Christophe Cornily,et al.  Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis. , 2006, Journal of the American College of Cardiology.

[18]  Robert H. Anderson,et al.  Anatomy of the Aortic Valvar Complex and Its Implications for Transcatheter Implantation of the Aortic Valve , 2008, Circulation. Cardiovascular interventions.

[19]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[20]  A. Cribier,et al.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. , 2006, Journal of the American College of Cardiology.

[21]  Dieter zur Nedden,et al.  Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity. , 2006, Journal of the American College of Cardiology.

[22]  J. Serfaty,et al.  Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography , 2007, Heart.

[23]  Jeroen J. Bax,et al.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. , 2008, JACC. Cardiovascular imaging.

[24]  R. Moss,et al.  Role of echocardiography in percutaneous aortic valve implantation. , 2008, JACC. Cardiovascular imaging.

[25]  Helmut Baumgartner,et al.  Guidelines on the management of valvular heart disease The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology , 2007 .

[26]  Mark A. Friedman,et al.  Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT , 2008, The International Journal of Cardiovascular Imaging.

[27]  A. Stillman,et al.  Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? , 2008, JACC. Cardiovascular interventions.

[28]  J. Chambers,et al.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[29]  M. Cheitlin Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery , 2007 .

[30]  A. Shiran,et al.  Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.