Comparison of Baseline Wander Removal Techniques considering the Preservation of ST Changes in the Ischemic ECG: A Simulation Study

The most important ECG marker for the diagnosis of ischemia or infarction is a change in the ST segment. Baseline wander is a typical artifact that corrupts the recorded ECG and can hinder the correct diagnosis of such diseases. For the purpose of finding the best suited filter for the removal of baseline wander, the ground truth about the ST change prior to the corrupting artifact and the subsequent filtering process is needed. In order to create the desired reference, we used a large simulation study that allowed us to represent the ischemic heart at a multiscale level from the cardiac myocyte to the surface ECG. We also created a realistic model of baseline wander to evaluate five filtering techniques commonly used in literature. In the simulation study, we included a total of 5.5 million signals coming from 765 electrophysiological setups. We found that the best performing method was the wavelet-based baseline cancellation. However, for medical applications, the Butterworth high-pass filter is the better choice because it is computationally cheap and almost as accurate. Even though all methods modify the ST segment up to some extent, they were all proved to be better than leaving baseline wander unfiltered.

[1]  Olaf Dössel,et al.  Binary optimization for source localization in the inverse problem of ECG , 2014, Medical & Biological Engineering & Computing.

[2]  O. Dössel,et al.  The impact of baseline wander removal techniques on the ST segment in simulated ischemic 12-lead ECGs , 2015 .

[3]  Paul S Addison,et al.  Wavelet transforms and the ECG: a review , 2005, Physiological measurement.

[4]  Franz Halberg,et al.  Circadian rhythmic fractal scaling of heart rate variability in health and coronary artery disease , 1997, Clinical cardiology.

[5]  Eric Kerfoot,et al.  Verification of cardiac tissue electrophysiology simulators using an N-version benchmark , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[6]  Fayyaz A. Afsar,et al.  A Comparison of Baseline Removal Algorithms for Electrocardiogram (ECG) Based Automated Diagnosis of Coronory Heart Disease , 2009, 2009 3rd International Conference on Bioinformatics and Biomedical Engineering.

[7]  Mel Herbert,et al.  EKG Criteria for Fibrinolysis: What’s Up with the J Point? , 2008, The western journal of emergency medicine.

[8]  I Dotsinsky,et al.  Optimization of bi-directional digital filtering for drift suppression in electrocardiogram signals , 2004, Journal of medical engineering & technology.

[9]  Vincent Heuveline,et al.  Framework for Modular, Flexible and Efficient Solving the Cardiac Bidomain Equations Using PETSc , 2010 .

[10]  O. H. Schmitt,et al.  Report of committee on electrocardiography, American Heart Association. Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography. , 1967, Circulation.

[11]  G. Lamas,et al.  ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction--executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1999 guidelines for the management of patients wi , 2004, Journal of the American College of Cardiology.

[12]  S. Luo,et al.  A review of electrocardiogram filtering. , 2010, Journal of electrocardiology.

[13]  P. Caminal,et al.  Adaptive baseline wander removal in the ECG: Comparative analysis with cubic spline technique , 1992, Proceedings Computers in Cardiology.

[14]  George B. Moody,et al.  Derivation of Respiratory Signals from Multi-lead ECGs , 2008 .

[15]  Olaf Dössel,et al.  Ranking the Influence of Tissue Conductivities on Forward-Calculated ECGs , 2010, IEEE Transactions on Biomedical Engineering.

[16]  O. E. Herrmann,et al.  ECG baseline wander reduction using linear phase filters. , 1986, Computers and biomedical research, an international journal.

[17]  Patrick E. McSharry,et al.  A dynamical model for generating synthetic electrocardiogram signals , 2003, IEEE Transactions on Biomedical Engineering.

[18]  Sophia Zhou,et al.  Detection of acute myocardial infarction using the 12‐lead ECG plus inverted leads versus the 16‐lead ECG (with additional posterior and right‐sided chest electrodes) , 2007, Clinical physiology and functional imaging.

[19]  D. Nunan,et al.  A Quantitative Systematic Review of Normal Values for Short‐Term Heart Rate Variability in Healthy Adults , 2010, Pacing and clinical electrophysiology : PACE.

[20]  Jacek M. Leski,et al.  ECG baseline wander and powerline interference reduction using nonlinear filter bank , 2005, Signal Process..

[21]  K. L. Park,et al.  Application of a wavelet adaptive filter to minimise distortion of the ST-segment , 1998, Medical and Biological Engineering and Computing.

[22]  Manuel Blanco-Velasco,et al.  ECG signal denoising and baseline wander correction based on the empirical mode decomposition , 2008, Comput. Biol. Medicine.

[23]  Conor Heneghan,et al.  Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea , 2003, IEEE Transactions on Biomedical Engineering.

[24]  R. Winkle,et al.  Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis. , 1982, American heart journal.

[25]  J. van Alsté,et al.  Removal of Base-Line Wander and Power-Line Interference from the ECG by an Efficient FIR Filter with a Reduced Number of Taps , 1985, IEEE Transactions on Biomedical Engineering.

[26]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Circulation.

[27]  Mahesh S. Chavan Suppression of Baseline Wander and power line interference in ECG using Digital IIR Filter , 2008 .

[28]  Antoun Khawaja,et al.  Automatic ECG Analysis using Principal Component Analysis and Wavelet Transformation , 2009 .

[29]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[30]  R. Zeballos,et al.  Clinical exercise testing. , 2001, Clinics in chest medicine.

[31]  V F Froelicher,et al.  Problems and limitations of ECG baseline estimation and removal using a cubic spline technique during exercise ECG testing: recommendations for proper implementation. , 1988, Journal of electrocardiology.

[32]  H N Keiser,et al.  Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniques. , 1977, Computers and biomedical research, an international journal.

[33]  K H W J Ten Tusscher,et al.  Cell model for efficient simulation of wave propagation in human ventricular tissue under normal and pathological conditions , 2006, Physics in medicine and biology.

[34]  I. I. Christov,et al.  High-pass filtering of ECG signals using QRS elimination , 2006, Medical and Biological Engineering and Computing.

[35]  P. Thompson,et al.  ACSM's Guidelines for Exercise Testing and Prescription , 1995 .

[36]  Mathias Wilhelms,et al.  Determination of optimal electrode positions of a wearable ECG monitoring system for detection of myocardial ischemia: A simulation study , 2011, 2011 Computing in Cardiology.

[37]  José Luis Rojo-Álvarez,et al.  Post extrasystolic T wave change in subjectswith structural healthy ventricles - Measurement and simulation , 2014, Computing in Cardiology 2014.

[38]  R. Pallàs-Areny,et al.  The effect of respiration-induced heart movements on the ECG , 1989, IEEE Transactions on Biomedical Engineering.

[39]  Jesús Lázaro,et al.  Separating the effect of respiration on the heart rate variability using Granger's causality and linear filtering , 2017, Biomed. Signal Process. Control..

[40]  Olaf Dössel,et al.  Ectopic beats and their influence on the morphology of subsequent waves in the electrocardiogram , 2013, Biomedizinische Technik. Biomedical engineering.

[41]  L. Porto,et al.  Comparison of Time‐Domain Short‐Term Heart Interval Variability Analysis Using a Wrist‐Worn Heart Rate Monitor and the Conventional Electrocardiogram , 2009, Pacing and clinical electrophysiology : PACE.

[42]  Kayvan Najarian,et al.  A Hierarchical Method for Removal of Baseline Drift from Biomedical Signals: Application in ECG Analysis , 2013, TheScientificWorldJournal.

[43]  Mathias Wilhelms,et al.  In Silico Investigation of Electrically Silent Acute Cardiac Ischemia in the Human Ventricles , 2011, IEEE Transactions on Biomedical Engineering.

[44]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[45]  Dd. Streeter,et al.  Gross morphology and fiber geometry of the heart , 1979 .

[46]  K. T. ten Tusscher,et al.  Alternans and spiral breakup in a human ventricular tissue model. , 2006, American journal of physiology. Heart and circulatory physiology.

[47]  Olaf Dössel,et al.  P wave detection and delineation in the ECG based on the phase free stationary wavelet transform and using intracardiac atrial electrograms as reference , 2016, Biomedizinische Technik. Biomedical engineering.

[48]  Mathias Wilhelms,et al.  ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation , 2015, BioMed research international.

[49]  L. Gamero,et al.  Wavelet transform analysis of heart rate variability during myocardial ischaemia , 2006, Medical and Biological Engineering and Computing.

[50]  Olaf Dössel,et al.  Influence of ${I_{Ks}}$ Heterogeneities on the Genesis of the T-wave: A Computational Evaluation , 2012, IEEE Transactions on Biomedical Engineering.