A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma.

A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, has been developed for the determination of the analgesic fentanyl in human plasma. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction (SPE) was carried out using a 96-channel programmable liquid-handling workstation using a mixed-mode sorbent. The extracted samples were then dried down, reconstituted and injected onto a silica column using an aqueous/organic mobile phase with tandem mass spectrometric detection. The method has been validated over the concentration range 0.05-100 ng/mL fentanyl in human plasma, based on a 0.25-mL sample size. The assay is sensitive, specific and robust. More than 2000 samples have been analyzed using this method. The automation of the sample preparation steps not only increased the analysis throughput, but also facilitated the transfer of the method between different bioanalytical laboratories of the same organization.

[1]  T. Baker,et al.  Automated 96-well SPE and LC-MS-MS for determination of protease inhibitors in plasma and cartilage tissues. , 2000, Analytical chemistry.

[2]  S. Fischer,et al.  Signal enhancement for gradient reverse-phase high-performance liquid chromatography-electrospray ionization mass spectrometry analysis with trifluoroacetic and other strong acid modifiers by postcolumn addition of propionic acid and isopropanol , 1995, Journal of the American Society for Mass Spectrometry.

[3]  S. Pleasance,et al.  The Use of Automated Solid Phase Extraction in the '96 well' Format for High Throughput Bioanalysis using Liquid Chromatography Coupled to Tandem Mass Spectrometry , 1996 .

[4]  J. Lee,et al.  Simultaneous assay of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma using normal-phase liquid chromatography-tandem mass spectrometry with a silica column and an aqueous organic mobile phase. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[5]  B. Matuszewski,et al.  Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations. , 1998, Analytical chemistry.

[6]  D L Buhrman,et al.  Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression , 1996, Journal of the American Society for Mass Spectrometry.

[7]  E. Woolf,et al.  Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection. , 1998, Journal of pharmaceutical and biomedical analysis.

[8]  F. Tse,et al.  Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin) in human plasma. , 2000, Rapid communications in mass spectrometry : RCM.

[9]  C. van Boxtel,et al.  Simultaneous determination of fentanyl and midazolam using high-performance liquid chromatography with ultraviolet detection. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[10]  J. Wieling,et al.  'High throughput' solid-phase extraction technology and turbo ionspray LC-MS-MS applied to the determination of haloperidol in human plasma. , 1999, Journal of pharmaceutical and biomedical analysis.

[11]  J. L. Huang,et al.  Determination of subnanogram concentrations of fentanyl in plasma by gas chromatography-mass spectrometry: comparison with standard radioimmunoassay. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[12]  K. Hoffmaster,et al.  Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometry. , 1997, Rapid communications in mass spectrometry : RCM.

[13]  K. Newland,et al.  Development and validation of a sensitive method for hydromorphone in human plasma by normal phase liquid chromatography-tandem mass spectrometry. , 2000, Journal of pharmaceutical and biomedical analysis.

[14]  J. Henion,et al.  Liquid-liquid extraction in the 96-well plate format with SRM LC/MS quantitative determination of methotrexate and its major metabolite in human plasma. , 1999, Analytical chemistry.

[15]  S. Pleasance,et al.  A clinical trial on a plate? The potential of 384-well format solid phase extraction for high-throughput bioanalysis using liquid chromatography/tandem mass spectrometry. , 2001, Rapid communications in mass spectrometry : RCM.

[16]  M. Jemal High-throughput quantitative bioanalysis by LC/MS/MS. , 2000, Biomedical chromatography : BMC.

[17]  V. Dixit,et al.  Solid-phase extraction of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid from human urine with gas chromatographic-mass spectrometric confirmation. , 1991, Journal of chromatography.

[18]  Z. Ouyang,et al.  Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by high-performance liquid chromatography with tandem mass spectrometry. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[19]  D. T. Rossi,et al.  Automated solid-phase extraction workstations combined with quantitative bioanalytical LC/MS. , 1999, Journal of pharmaceutical and biomedical analysis.

[20]  D. Wu,et al.  High throughput liquid chromatography/mass spectrometry bioanalysis using 96-well disk solid phase extraction plate for the sample preparation. , 1998, Rapid communications in mass spectrometry : RCM.

[21]  J. Henion,et al.  High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12 hours. , 1999, Analytical Chemistry.

[22]  D. Crankshaw,et al.  Determination of fentanyl and alfentanil in plasma by high-performance liquid chromatography with ultraviolet detection. , 1987, Journal of chromatography.

[23]  A P Watt,et al.  Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS. , 2000, Analytical chemistry.

[24]  S. Pleasance,et al.  Automated protein precipitation by filtration in the 96-well format. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[25]  D R Stanski,et al.  Assay methods for fentanyl in serum: gas-liquid chromatography versus radioimmunoassay. , 1987, Anesthesiology.

[26]  J Schüttler,et al.  Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum. , 1984, Anesthesiology.