Refractive index sensor using microfiber-based Mach-Zehnder interferometer.

A simple and robust refractive index (RI) sensor based on a Mach-Zehnder interferometer has been demonstrated. A section of optical microfiber drawn from silica fiber is employed as the sensing arm. Because of the evanescent field, a slight change of the ambient RI will lead to the variation of the microfiber propagation constant, which will further change the optical length. In order to compensate the variation of the optical length difference, a tunable optical delay line (ODL) is inserted into the other arm. By measuring the delay of the ODL, the ambient RI can be simply demodulated. A high RI sensitivity of about 7159  μm/refractive index unit is achieved at microfiber diameter of 2.0 μm.

[1]  Yongmin Jung,et al.  Adiabatically tapered splice for selective excitation of the fundamental mode in a multimode fiber. , 2009, Optics letters.

[2]  Fei Xu,et al.  Demonstration of a refractometric sensor based on optical microfiber coil resonator , 2008, 2008 Conference on Lasers and Electro-Optics and 2008 Conference on Quantum Electronics and Laser Science.

[3]  R. Rosenfeld Nature , 2009, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[4]  Yu Zhang,et al.  Refractive index sensing based on higher-order mode reflection of a microfiber Bragg grating. , 2010, Optics express.

[5]  M. Mansuripur,et al.  Evanescent field-based optical fiber sensing device for measuring the refractive index of liquids in microfluidic channels. , 2005, Optics letters.

[6]  D N Wang,et al.  Twisted Optical Microfibers for Refractive Index Sensing , 2011, IEEE Photonics Technology Letters.

[7]  Limin Tong,et al.  Supported microfiber loops for optical sensing. , 2008, Optics express.

[8]  Yuhang Li,et al.  Mach-Zehnder interferometers assembled with optical microfibers or nanofibers. , 2008, Optics letters.

[9]  Jacques Bures,et al.  Power density of the evanescent field in the vicinity of a tapered fiber , 1999 .

[10]  Limin Tong,et al.  Single-mode guiding properties of subwavelength-diameter silica and silicon wire waveguides. , 2004, Optics express.

[11]  G. White,et al.  Thermal expansion of reference materials: copper, silica and silicon , 1973 .

[12]  Peter Horak,et al.  Optical microfiber coil resonator refractometric sensor. , 2007, Optics express.

[13]  C. Liao,et al.  Femtosecond laser fabricated fiber Bragg grating in microfiber for refractive index sensing. , 2010, Optics letters.

[14]  Toshimi Kominato,et al.  Silica-Based Integrated Optic Mach-Zehnder Multi/Demultiplexer Family with Channel Spacing of 0.01-250 nm , 1990, IEEE J. Sel. Areas Commun..

[15]  F. D. Pereira,et al.  A New Double Beam Optical Lever Refractometer and the Variation of the Refractive Index of NaCl with Temperature , 1971 .

[16]  S. Ghalmi,et al.  Fabrication of miniature optical fiber and microfiber coils , 2010 .

[17]  S. Leon-Saval,et al.  Supercontinuum generation in submicron fibre waveguides. , 2004, Optics express.

[18]  Limin Tong,et al.  Modeling of evanescent coupling between two parallel optical nanowires. , 2007, Applied optics.

[19]  M Sumetsky How thin can a microfiber be and still guide light? , 2006, Optics letters.

[20]  A. Boudrioua Optical Waveguide Theory , 2010 .