A procedure for the direct determination of the required supplemental damping for the seismic retrofit with viscous dampers

Abstract This paper describes a simplified procedure to calculate the supplemental damping ratio that must be provided in order to rehabilitate existing buildings with viscous dampers. The proposed method has been developed according to both analytical and graphical approaches. The graphical formulation is based on the construction of constant design acceleration or constant design displacement curves. These curves allow to estimate the required effective damping as a function of the effective period, associated to the secant stiffness at maximum displacement. Combining these curves with constant ductility curves, which provide a correlation between the effective damping and the supplemental damping for given available ductility and damper typology, it is possible to determine the required supplemental damping and to design the damping system. The proposed method has then been verified through nonlinear dynamic analyses considering a set of RC plane frames. Finally it has been applied to a case study regarding an existing building located in Italy and designed without considering the earthquake action.

[1]  Izuru Takewaki,et al.  Non-monotonic optimal damper placement via steepest direction search , 1999 .

[2]  Luca Landi,et al.  On the Design of Viscous Dampers for the Rehabilitation of Plan-Asymmetric Buildings , 2013 .

[3]  T. T. Soong,et al.  Seismic Design of Viscoelastic Dampers for Structural Applications , 1992 .

[4]  Anita Shukla,et al.  Optimal Use of Viscoelastic Dampers in Building Frames for Seismic Force , 1999 .

[5]  William T. Holmes,et al.  The 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures , 2000 .

[6]  T. T. Soong,et al.  Efficiency of a simple approach to damper allocation in MDOF structures , 2002 .

[7]  Luca Landi,et al.  Simplified method for the assessment of the nonlinear seismic response of structures equipped with viscous dampers , 2013 .

[8]  Jinkoo Kim,et al.  PERFORMANCE-BASED DESIGN OF ADDED VISCOUS DAMPERS USING CAPACITY SPECTRUM METHOD , 2003 .

[9]  Izuru Takewaki,et al.  Optimal damper placement for minimum transfer functions , 1997 .

[10]  J. N. Yang,et al.  Design of Passive Energy Dissipation Systems Based on LQR Control Methods , 1999 .

[11]  M. Constantinou,et al.  Elastic and Inelastic Seismic Response of Buildings with Damping Systems , 2002 .

[12]  T. T. Soong,et al.  Passive Energy Dissipation Systems for Structural Design and Retrofit , 1998 .

[13]  Mahendra P. Singh,et al.  Optimal seismic response control with dampers , 2001 .

[14]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[15]  Gary F. Dargush,et al.  Evolutionary aseismic design and retrofit of structures with passive energy dissipation , 2005 .

[16]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[17]  Kuo-Chun Chang,et al.  Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers , 2008 .

[18]  Gary F. Dargush,et al.  Multi-Objective Evolutionary Seismic Design with Passive Energy Dissipation Systems , 2009 .

[19]  M. Fardis,et al.  Deformations of Reinforced Concrete Members at Yielding and Ultimate , 2001 .

[20]  Michael C. Constantinou,et al.  Seismic response of structures with supplemental damping , 1993 .

[21]  Diego Lo´pez Garci´a A Simple Method for the Design of Optimal Damper Configurations in MDOF Structures , 2001 .

[22]  Luca Landi,et al.  A Methodology for the Direct Assessment of the Damping Ratio of Structures Equipped with Nonlinear Viscous Dampers , 2012 .

[23]  Anil K. Chopra,et al.  Dynamics of Structures: Theory and Applications to Earthquake Engineering , 1995 .

[24]  Andrea Benedetti,et al.  Rehabilitation of existing masonry structures with hysteretic dampers: A displacement based approach , 2014 .

[25]  Timothy J. Sullivan,et al.  Towards a simplified Direct DBD procedure for the seismic design of moment resisting frames with viscous dampers , 2012 .

[26]  Fahim Sadek,et al.  Linear Procedures for Structures with Velocity-Dependent Dampers , 2000 .

[27]  Oren Lavan,et al.  Fully stressed design of passive controllers in framed structures for seismic loadings , 2006 .

[28]  Tomaso Trombetti,et al.  A Five-Step Procedure for the Dimensioning of Viscous Dampers to Be Inserted in Building Structures , 2010 .

[29]  G. D. Hahn,et al.  Effects of added-damper distribution on the seismic response of buildings , 1992 .

[30]  Yu-Yuan Lin,et al.  Study on Damping Reduction Factor for Buildings under Earthquake Ground Motions , 2003 .

[31]  J. S. Hwang,et al.  Comparison of distribution methods for viscous damping coefficients to buildings , 2010 .