Development of a mechanism-based, DNA staining protocol using SYTOX orange nucleic acid stain and DNA fragment sizing flow cytometry.

Accurate measurement of single DNA fragments by DNA fragment sizing flow cytometry (FSFC) depends upon precise, stoichiometric DNA staining by the intercalating dye molecules. In this study, we determined the binding characteristics of a commercially available 532 nm wavelength-excitable dye and used this information to develop a universal DNA staining protocol for DNA FSFC using a compact frequency-doubled Nd:YAG laser excitation source. Among twelve 532 nm wavelength-excitable nucleic acid staining dyes tested, SYTOX Orange stain showed the highest fluorescence intensity along with a large fluorescence enhancement upon binding to double-stranded DNA ( approximately 450-fold). Furthermore, using SYTOX Orange stain, accurate fragment-size-distribution histograms were consistently obtained without regard to the staining dye to base pair (dye/bp) ratio. A model describing two binding modes, intercalation (primary, yielding fluorescence) and external binding (secondary, involving fluorescence quenching), was proposed to interpret the performance of the dyes under different dye/bp ratios. The secondary equilibrium dissociation constant was found to be the most critical parameter in determining the sensitivity of each fluorophore to the staining dye/bp ratio. The measurements of both equilibrium dissociation constants provided us with a theoretical framework for developing a universal protocol which was successfully demonstrated over a wide range of DNA concentrations on a compact flow cytometer equipped with a frequency-doubled, diode-pumped, solid-state Nd:YAG laser for rapid and sensitive DNA fragment sizing.

[1]  Mats Jonsson,et al.  Characterization of the Binding of the Fluorescent Dyes Yo and Yoyo to DNA by Polarized-Light Spectroscopy , 1994 .

[2]  J. Jett,et al.  Bacteria genome fingerprinting by flow cytometry. , 1999, Cytometry.

[3]  Bjorn Akerman,et al.  Double bands in DNA gel electrophoresis caused by bis-intercalating dyes , 1995, Nucleic Acids Res..

[4]  M. Morris,et al.  Separation of nucleic acids by capillary electrophoresis in cellulose solutions with mono- and bis-intercalating dyes. , 1994, Analytical chemistry.

[5]  A. Castro,et al.  Fluorescence detection and size measurement of single DNA molecules , 1993 .

[6]  J. Jett,et al.  Bacterial fingerprinting by flow cytometry: bacterial species discrimination. , 1999, Cytometry.

[7]  Richard P. Haugland,et al.  Handbook of fluorescent probes and research chemicals , 1996 .

[8]  D. Crothers Calculation of binding isotherms for heterogeneous polymers , 1968, Biopolymers.

[9]  K. Takata,et al.  Nuclear Staining for Laser Confocal Microscopy , 1997 .

[10]  S M Clark,et al.  Multiplex dsDNA Fragment Sizing Using Dimeric Intercalation Dyes and Capillary Array Electrophoresis:  Ionic Effects on the Stability and Electrophoretic Mobility of DNA-Dye Complexes. , 1997, Analytical chemistry.

[11]  B. Nordén,et al.  Optical and Photophysical Properties of the Oxazole Yellow DNA Probes YO and YOYO , 1994 .

[12]  J. Jett,et al.  Characteristics of different nucleic acid staining dyes for DNA fragment sizing by flow cytometry. , 1999, Analytical chemistry.

[13]  P. Dervan,et al.  Molecular recognition of nucleic acid by small molecules. Binding affinity and structural specificity of bis(methidium)spermine , 1979 .

[14]  W. P. Ambrose,et al.  Rapid sizing of individual fluorescently stained DNA fragments by flow cytometry. , 1993, Nucleic acids research.

[15]  D. Wemmer,et al.  Solution structure of a DNA complex with the fluorescent bis-intercalator TOTO determined by NMR spectroscopy. , 1995, Biochemistry.

[16]  J H Jett,et al.  Large DNA fragment sizing by flow cytometry: application to the characterization of P1 artificial chromosome (PAC) clones. , 1996, Nucleic acids research.

[17]  Alexander N. Glazer,et al.  Stable dye–DNA intercalation complexes as reagents for high-sensitivity fluorescence detection , 1992, Nature.

[18]  D. Figeys,et al.  Use of the fluorescent intercalating dyes POPO-3, YOYO-3 and YOYO-1 for ultrasensitive detection of double-stranded DNA separated by capillary electrophoresis with hydroxypropylmethyl cellulose and non-cross-linked polyacrylamide , 1994 .

[19]  J. Greve,et al.  Two-color fluorescence in flow cytometry DNA sizing : Identification of single-molecule fluorescent probes , 1999 .

[20]  R. Mathies,et al.  Fluorometric assay using dimeric dyes for double- and single-stranded DNA and RNA with picogram sensitivity. , 1993, Analytical biochemistry.

[21]  L. Lerman,et al.  Structural considerations in the interaction of DNA and acridines. , 1961, Journal of molecular biology.

[22]  S. Clark,et al.  High-sensitivity capillary electrophoresis of double-stranded DNA fragments using monomeric and dimeric fluorescent intercalating dyes. , 1994, Analytical chemistry.

[23]  D E Wemmer,et al.  Stable fluorescent complexes of double-stranded DNA with bis-intercalating asymmetric cyanine dyes: properties and applications. , 1992, Nucleic acids research.

[24]  Jeffrey T. Petty,et al.  Characterization of DNA Size Determination of Small Fragments by Flow Cytometry , 1995 .

[25]  J. Hayes,et al.  BINDING OF TO-PRO-3 AND TOTO-3 TO DNA : FLUORESCENCE AND HOLE-BURNING STUDIES , 1996 .