Functional dependence of cancellous bone shear properties on trabecular microstructure evaluated using time‐lapsed micro‐computed tomographic imaging and torsion testing

When compressed axially, cancellous bone often fails at an oblique angle along well‐defined bands, highlighting the importance of cancellous bone shear properties. Torsion testing to determine shear properties of cancellous bone has often been conducted under conditions appropriate only for axisymmetric specimens comprised of homogeneous and isotropic materials. However, most cancellous bone specimens do not meet these stringent test conditions. Therefore, we studied the application of the stepwise torsion testing system in biologic specimens with viscoelastic behavior. We explore the functional dependence of cancellous bone shear properties on trabecular microstructure and its spatial distribution, specifically the contribution of the subregion with the minimum polar moment of inertia to the overall failure properties. Torsional properties of whale trabecular specimens obtained by the incremental application of stepwise torque were not different from those obtained via continuous testing. Average polar moment of inertia accounted for 82 and 67% of the variation in shear modulus and shear stress, respectively. However, torsional properties were better predicted by the subregion with minimum polar moment of inertia, describing 87 and 74% of the variation in shear modulus and shear stress. The use of a novel torsion testing system for nonhomogeneous, orthotropic cancellous bone using stepwise application of torsion and simultaneous micro‐computed tomographic imaging was further studied. Most importantly, a heterogeneous cancellous bone microstructural environment, the subregion with the minimum polar moment of inertia, hence the weakest spatial distribution of bone, predicted the shear properties for the entire bone volume. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:1667–1674, 2009

[1]  Ralph Müller,et al.  Design and validation of a testing system to assess torsional cancellous bone failure in conjunction with time-lapsed micro-computed tomographic imaging. , 2008, Journal of biomechanics.

[2]  B. Snyder,et al.  The interaction of microstructure and volume fraction in predicting failure in cancellous bone. , 2006, Bone.

[3]  Ralph Müller,et al.  Design and implementation of a novel mechanical testing system for cellular solids. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[4]  Karl J Jepsen,et al.  Genetic Variation in Structure‐Function Relationships for the Inbred Mouse Lumbar Vertebral Body , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[5]  Joseph H. Nadeau,et al.  Hierarchical relationship between bone traits and mechanical properties in inbred mice , 2003, Mammalian Genome.

[6]  Ming Ding,et al.  Age‐related variations in the microstructure of human tibial cancellous bone , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  M. Ito,et al.  Effect of trabecular bone contour on ultimate strength of lumbar vertebra after bilateral ovariectomy in rats. , 2001, Bone.

[8]  L. Claes,et al.  Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur. , 2001, Clinical biomechanics.

[9]  R Müller,et al.  Variation in Bone Biomechanical Properties, Microstructure, and Density in BXH Recombinant Inbred Mice , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[10]  G. Niebur,et al.  High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. , 2000, Journal of biomechanics.

[11]  Matthew J. Silva,et al.  Growing C57Bl/6 Mice Increase Whole Bone Mechanical Properties by Increasing Geometric and Material Properties , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[12]  R Dumas,et al.  Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests. , 1999, Medical engineering & physics.

[13]  T M Keaveny,et al.  A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone. , 1999, Journal of biomechanical engineering.

[14]  W C Hayes,et al.  Micro-compression: a novel technique for the nondestructive assessment of local bone failure. , 1998, Technology and health care : official journal of the European Society for Engineering and Medicine.

[15]  J S Thomsen,et al.  Relationships between static histomorphometry and bone strength measurements in human iliac crest bone biopsies. , 1998, Bone.

[16]  L. Gibson,et al.  Modeling the mechanical behavior of vertebral trabecular bone: effects of age-related changes in microstructure. , 1997, Bone.

[17]  D Mitton,et al.  The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes. , 1997, Medical engineering & physics.

[18]  T M Keaveny,et al.  The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation. , 1996, Journal of biomechanics.

[19]  G. Beaupré,et al.  Improved method for analysis of whole bone torsion tests , 1994, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[20]  Steven D. Kugelmass,et al.  Relationship between NMR transverse relaxation, trabecular bone architecture, and strength. , 1993, Proceedings of the National Academy of Sciences of the United States of America.

[21]  R. Recker,et al.  Architecture and vertebral fracture , 1993, Calcified Tissue International.

[22]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[23]  M. Kleerekoper,et al.  Irreversible bone loss in osteomalacia. Comparison of radial photon absorptiometry with iliac bone histomorphometry during treatment. , 1985, The Journal of clinical investigation.

[24]  M. Kleerekoper,et al.  The role of three-dimensional trabecular microstructure in the pathogenesis of vertebral compression fractures , 1985, Calcified Tissue International.

[25]  M. Kleerekoper,et al.  Dissociation between the effects of endogenous parathyroid hormone on adenosine 3',5'-monophosphate generation and phosphate reabsorption in hypocalcemia due to vitamin D depletion: an acquired disorder resembling pseudohypoparathyroidism type II. , 1985, The Journal of clinical endocrinology and metabolism.

[26]  A. J. Lee,et al.  The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface , 1978, Archives of orthopaedic and traumatic surgery.

[27]  A. Burstein,et al.  The biomechanics of torsional fractures: the effect of loading on ultimate properties. , 1971, Journal of biomechanics.

[28]  O. J. Dunn,et al.  Correlation Coefficients Measured on the Same Individuals , 1969 .

[29]  Matthew R Allen,et al.  A computational assessment of the independent contribution of changes in canine trabecular bone volume fraction and microarchitecture to increased bone strength with suppression of bone turnover. , 2007, Journal of biomechanics.

[30]  M. Grynpas,et al.  On shear properties of trabecular bone under torsional loading: effects of bone marrow and strain rate. , 2007, Journal of biomechanics.

[31]  R. Müller,et al.  Time-lapsed microstructural imaging of bone failure behavior. , 2004, Journal of biomechanics.

[32]  P Rüegsegger,et al.  The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. , 1997, Studies in health technology and informatics.

[33]  C. Ford Failure of the human proximal femur : material and structural perspectives , 1996 .

[34]  D P Fyhrie,et al.  Failure mechanisms in human vertebral cancellous bone. , 1994, Bone.

[35]  Xiao-Li Meng,et al.  Comparing correlated correlation coefficients , 1992 .

[36]  R. B. Ashman,et al.  Elastic properties of cancellous bone: measurement by an ultrasonic technique. , 1987, Journal of biomechanics.

[37]  C. Christiansen,et al.  Bone mass, bone structure and vertebral fractures in osteoporotic patients. , 1987, Bone.

[38]  W. Hayes,et al.  Multiaxial strength characteristics of trabecular bone. , 1983, Journal of biomechanics.

[39]  Leonard R. Herrmann,et al.  Elastic Torsional Analysis of Irregular Shapes , 1965 .