Monolithically integrated broad-band Mach-Zehnder interferometers for highly sensitive label-free detection of biomolecules through dual polarization optics
暂无分享,去创建一个
K. Misiakos | S. E. Kakabakos | R. Stoffer | G. Jobst | E. Makarona | A. Botsialas | I. Raptis | P. S. Petrou | K. Misiakos | G. Jobst | M. Sopanen | A. Botsialas | I. Raptis | P. Petrou | S. Kakabakos | E. Makarona | R. Stoffer | M. Sopanen | A. Salapatas | A. Psarouli | K. Tukkiniemi | K. Tukkiniemi | A. Salapatas | A. Psarouli
[1] Xudong Fan,et al. On the performance quantification of resonant refractive index sensors. , 2008, Optics express.
[2] G Jobst,et al. Broad-band Mach-Zehnder interferometers as high performance refractive index sensors: theory and monolithic implementation. , 2014, Optics express.
[3] Xudong Fan,et al. Optofluidic Microsystems for Chemical and Biological Analysis. , 2011, Nature photonics.
[4] R. Heideman,et al. Remote opto-chemical sensing with extreme sensitivity: design, fabrication and performance of a pigtailed integrated optical phase-modulated Mach-Zehnder interferometer system , 1999 .
[5] Laura Sola,et al. A fast and simple label-free immunoassay based on a smartphone. , 2014, Biosensors & bioelectronics.
[6] Robert C. Wolpert,et al. A Review of the , 1985 .
[7] Guo-Qiang Lo,et al. Label-free aptamer sensor based on silicon microring resonators , 2013 .
[8] Y. C. Cheng,et al. Monolithic SU-8 micro-interferometer for biochemical detections , 2008 .
[9] Laura M. Lechuga,et al. Silicon Photonic Biosensors for Lab-on-a-Chip Applications , 2008 .
[10] Karl H. Wolf,et al. Comparative review , 2011, J. Documentation.
[11] R. Hainberger,et al. Integrated polymer-based Mach-Zehnder interferometer label-free streptavidin biosensor compatible with injection molding. , 2011, Biosensors & bioelectronics.
[12] Konstantinos Misiakos,et al. Fully integrated monolithic optoelectronic transducer for real-time protein and DNA detection: the NEMOSLAB approach. , 2010, Biosensors & bioelectronics.
[13] Ryan C Bailey,et al. Biomolecular analysis with microring resonators: applications in multiplexed diagnostics and interaction screening. , 2013, Current opinion in chemical biology.
[14] Erfan Zalnezhad,et al. Rapid Immunoglobulin M-Based Dengue Diagnostic Test Using Surface Plasmon Resonance Biosensor , 2014, Scientific Reports.
[15] Leimeng Zhuang,et al. Novel wideband microwave polarization network using a fully-reconfigurable photonic waveguide interleaver with a two-ring resonator-assisted asymmetric Mach-Zehnder structure. , 2013, Optics express.
[16] A. G. Chynoweth,et al. Photon Emission from Avalanche Breakdown in Silicon , 1956 .
[17] Aydogan Ozcan,et al. Handheld high-throughput plasmonic biosensor using computational on-chip imaging , 2014, Light: Science & Applications.
[18] Qingjun Liu,et al. Biosensors and bioelectronics on smartphone for portable biochemical detection. , 2016, Biosensors & bioelectronics.
[19] R. Horváth,et al. Effect of patterns and inhomogeneities on the surface of waveguides used for optical waveguide lightmode spectroscopy applications , 2001 .
[20] G Gauglitz,et al. Optical biosensors. Monitoring studies of glycopeptide antibiotic fermentation using white light interference. , 2001, Analytical chemistry.
[21] Katrin Schmitt,et al. Interferometric biosensor based on planar optical waveguide sensor chips for label-free detection of surface bound bioreactions. , 2007, Biosensors & bioelectronics.
[22] K. Misiakos,et al. Label-free kinetic study of biomolecular interactions by white light reflectance spectroscopy , 2006 .
[23] T F McGrath,et al. Biosensors for the analysis of microbiological and chemical contaminants in food , 2012, Analytical and Bioanalytical Chemistry.
[24] Ioannis Raptis,et al. Real-time label-free detection of complement activation products in human serum by white light reflectance spectroscopy. , 2009, Biosensors & bioelectronics.
[25] G. Jobst,et al. Integrated optical pH sensor using replicated chirped grating coupler sensor chips , 1998 .
[26] Frank F Bier,et al. Integrated planar optical waveguide interferometer biosensors: a comparative review. , 2014, Biosensors & bioelectronics.
[27] Konstantinos Misiakos,et al. A monolithic silicon optoelectronic transducer as a real-time affinity biosensor. , 2004, Analytical chemistry.
[28] Aydogan Ozcan,et al. Cellphone-based devices for bioanalytical sciences , 2014, Analytical and Bioanalytical Chemistry.
[29] Mi Kyoung Park,et al. Single-channel Mach-Zehnder interferometric biochemical sensor based on two-lateral-mode spiral waveguide. , 2014, Optics express.
[30] J. Cronin,et al. The resonant mirror: a novel optical biosensor for direct sensing of biomolecular interactions Part I: Principle of operation and associated instrumentation , 1992 .
[31] W. Lukosz,et al. Integrated optical chemical and direct biochemical sensors , 1995 .
[32] K. Misiakos,et al. All-silicon monolithic Mach-Zehnder interferometer as a refractive index and bio-chemical sensor. , 2014, Optics express.