Abstract Analytical solutions for the evaluation of the behaviour of steel connections are presented which are able to reproduce their full non-linear behaviour. Because usual models for the analysis of steel connections consist of translational springs and rigid links whereby the springs exhibit a non-linear force–deformation response, usually taken as a bi-linear approximation, they require an incremental non-linear analysis. Using a substitute elastic post-buckling model where each bi-linear spring is replaced by two equivalent elastic springs in the context of a post-buckling stability analysis using an energy formulation, closed-form solutions are obtained for a connection loaded in bending. Application to a beam-to-column welded connection using the component (spring) characterisation of code regulations yields the same results in terms of moment resistance and initial stiffness, being additionally able to trace the full unstiffening response.
[1]
Bao Guangjian,et al.
The design and on-site construction of shenzhen 384 m high level emperor skyscraper in China
,
1998
.
[2]
Giles W Hunt,et al.
Hidden asymmetries in the Shanley model
,
1985
.
[3]
Jean-Pierre Jaspart,et al.
The stiffness model of revised annex j of eurocode 3
,
1996
.
[4]
Jean-Pierre Jaspart,et al.
Etude de la semi-rigidité des noeuds poutre-colonne et son influence sur la résistance et la stabilité des ossatures en acier
,
1991
.
[5]
Paulo J. S. Cruz,et al.
Database for the Semi-rigid Behaviour of Beam-to- column Connections in Seismic Regions
,
1998
.