Identification errors involving clinical laboratories: a College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions.

CONTEXT Misidentified laboratory specimens may cause patient injury, but their frequency in general laboratory practice is unknown. OBJECTIVES To determine (1) the frequency of identification errors detected before and after result verification, (2) the frequency of adverse patient events due to specimen misidentification, and (3) factors associated with lower error rates and better detection of errors. DESIGN One hundred twenty clinical laboratories provided information about identification errors during 5 weeks. RESULTS In aggregate, 85% of errors were detected before results were released; one quarter of laboratories identified more than 95% of errors before result verification. The overall rate of patient identification errors involving released results was 55 errors per 1,000,000 billable tests. A total of 345 adverse events were reported. Most of the adverse events caused material inconvenience to the patients but did not result in any permanent harm. On average, adverse events resulted from 1 of every 18 identification errors. Extrapolating the adverse event rate observed in this study to all United States hospital-based laboratories suggests that more than 160,000 adverse events per year result from misidentification of patients' laboratory specimens. CONCLUSIONS Identification errors are common in laboratory medicine, but most are detected before results are released, and only a fraction are associated with adverse patient events. Even when taking into consideration the design of this study, which used imperfect case finding, institutions that did a better job of detecting errors within the laboratory released a smaller proportion of results that involved specimen misidentification.

[1]  J. Lumadue,et al.  Adherence to a strict specimen‐labeling policy decreases the incidence of erroneous blood grouping of blood bank specimens , 1997, Transfusion.

[2]  Howanitz Pj,et al.  Ordering accuracy. A College of American Pathologists Q-Probes study of 577 institutions. , 1995 .

[3]  Kaveh G Shojania,et al.  Classifying laboratory incident reports to identify problems that jeopardize patient safety. , 2003, American journal of clinical pathology.

[4]  E Raik Error rates in Australian chemical pathology laboratories , 1996, The Medical journal of Australia.

[5]  J. Linden,et al.  A report of 104 transfusion errors in New York State , 1992, Transfusion.

[6]  James T. Reason,et al.  Managing the risks of organizational accidents , 1997 .

[7]  K. Sazama,et al.  Reports of 355 transfusion‐associated deaths: 1976 through 1985 , 1990, Transfusion.

[8]  David R Colard Reduction of Patient Identification Errors Using Technology , 2005 .

[9]  A. Dighe,et al.  Implementation of Bar Coded Wristbands in a Large Academic Medical Center: Impact on Point of Care Error Rates , 2005 .

[10]  Mario Plebani,et al.  Errors in laboratory medicine. , 2002, Clinical chemistry.

[11]  P Bachner,et al.  Wristband identification error reporting in 712 hospitals. A College of American Pathologists' Q-Probes study of quality issues in transfusion practice. , 1993, Archives of pathology & laboratory medicine.

[12]  R. Nakhleh,et al.  Surgical pathology specimen identification and accessioning: A College of American Pathologists Q-Probes Study of 1 004 115 cases from 417 institutions. , 1996, Archives of pathology & laboratory medicine.

[13]  L. Kohn,et al.  To Err Is Human : Building a Safer Health System , 2007 .

[14]  M Plebani,et al.  Mistakes in a stat laboratory: types and frequency. , 1997, Clinical chemistry.

[15]  P. J. Howanitz Quality assurance measurements in departments of pathology and laboratory medicine. , 1990, Archives of pathology & laboratory medicine.

[16]  L. Kohn,et al.  COMMITTEE ON QUALITY OF HEALTH CARE IN AMERICA , 2000 .

[17]  P. Valenstein,et al.  Identification errors in pathology and laboratory medicine. , 2004, Clinics in laboratory medicine.

[18]  L. Leape Error in medicine. , 1994, JAMA.

[19]  W. Oosterhuis,et al.  Evaluation of LabRespond, a new automated validation system for clinical laboratory test results. , 2000, Clinical chemistry.

[20]  R. Robertson Error rates in Australian chemical pathology laboratories. , 1996, The Medical journal of Australia.

[21]  C. Marano,et al.  To err is human. Building a safer health system , 2005 .

[22]  M. Sherman,et al.  Rapid identification of patient specimens with microsatellite DNA markers. , 1996, Modern pathology : an official journal of the United States and Canadian Academy of Pathology, Inc.

[23]  P. J. Howanitz,et al.  Ordering accuracy. A College of American Pathologists Q-Probes study of 577 institutions. , 1995, Archives of pathology & laboratory medicine.

[24]  J. Killeen Impact of Bar Coding Technology and Computerized Physician Order Entry on Reducing Laboratory Specimen Misidentification Errors in the Emergency Department , 2005 .

[25]  D. Troxel,et al.  Error in Surgical Pathology , 2004, The American journal of surgical pathology.

[26]  M. Murphy,et al.  An international study of the performance of sample collection from patients , 2003, Vox sanguinis.

[27]  A. Wall,et al.  Book ReviewTo Err is Human: building a safer health system Kohn L T Corrigan J M Donaldson M S Washington DC USA: Institute of Medicine/National Academy Press ISBN 0 309 06837 1 $34.95 , 2000 .

[28]  Clarence C. Rodrigues,et al.  Commercial Aviation Safety , 1991 .