Economics of greenhouse heating with a mine air-assisted heat pump
暂无分享,去创建一个
An analysis of the economics of greenhouse heating with a heat pump coupled with an inactive deep mine is presented. Several heat pump and conventional gas-fired heater combinations (hybrid systems) were evaluated using a computer model to perform thermal and economic analyses. A 10 ¥ 30 m, double-polyethylene-covered greenhouse, located in Charleston, West Virginia, was assumed for this analysis. Heat pumps with sufficient capacity to maintain 21° C inside the greenhouse for outside temperatures ranging from 0 to 20° C (in 2° degree increments) were modeled. For each heat pump capacity, it was assumed that the additional heat energy required to maintain the specified inside temperature (when outside temperature fell below the heat pump design temperature) was supplied by a natural gas-fired heater. Life-cycle cost analysis was employed to compare greenhouse heating alternatives.
[1] George A. Duncan,et al. Composition of Coal Mine Air in Relationship to Greenhouse Environment Control , 1975 .
[2] John N. Walker,et al. Temperature and Humidity in a Greenhouse Ventilated With Coal Mine Air , 1976 .
[3] J. E. Bose,et al. Design/data manual for closed-loop ground-coupled heat pump systems , 1985 .
[4] L. S. Marsh,et al. Economically optimum day temperatures for greenhouse hydroponic lettuce production. I. A computer model , 1991 .