Finite Element Analysis of Hepatic Radiofrequency Ablation Probes using Temperature-Dependent Electrical Conductivity

BackgroundFew finite element models (FEM) have been developed to describe the electric field, specific absorption rate (SAR), and the temperature distribution surrounding hepatic radiofrequency ablation probes. To date, a coupled finite element model that accounts for the temperature-dependent electrical conductivity changes has not been developed for ablation type devices. While it is widely acknowledged that accounting for temperature dependent phenomena may affect the outcome of these models, the effect has not been assessed.MethodsThe results of four finite element models are compared: constant electrical conductivity without tissue perfusion, temperature-dependent conductivity without tissue perfusion, constant electrical conductivity with tissue perfusion, and temperature-dependent conductivity with tissue perfusion.ResultsThe data demonstrate that significant errors are generated when constant electrical conductivity is assumed in coupled electrical-heat transfer problems that operate at high temperatures. These errors appear to be closely related to the temperature at which the ablation device operates and not to the amount of power applied by the device or the state of tissue perfusion.ConclusionAccounting for temperature-dependent phenomena may be critically important in the safe operation of radiofrequency ablation device that operate near 100°C.

[1]  R. Clayman,et al.  In vivo comparison of electrosurgical vaporization electrodes. , 1997, Journal of endourology.

[2]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[3]  S. Singletary,et al.  Radiofrequency ablation of solid tumors. , 2001, Cancer journal.

[4]  H. Bassen,et al.  United States radiation safety and regulatory considerations for radiofrequency hyperthermia systems. , 1981, The Journal of microwave power.

[5]  H. Ueno,et al.  Radiofrequency ablation and percutaneous ethanol injection in patients with small hepatocellular carcinoma: a comparative study. , 2001, Japanese journal of clinical oncology.

[6]  I Chang,et al.  Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices. , 2002, Medical engineering & physics.

[7]  J. E. Sebben Monopolar and bipolar treatment. , 1989, The Journal of dermatologic surgery and oncology.

[8]  K R Foster,et al.  Myocardial Electrical Impedance Mapping of Ischemic Sheep Hearts and Healing Aneurysms , 1993, Circulation.

[9]  Mark S. Mirotznik,et al.  Electrical Impedance Properties of Normal and Chronically Infarcted Left Ventricular Myocardium , 1999, Journal of Interventional Cardiac Electrophysiology.

[10]  L. Welt Principles of Internal Medicine , 1955, The Yale Journal of Biology and Medicine.

[11]  Eung Je Woo,et al.  A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: finite element analysis and in vitro experiments , 2000, IEEE Transactions on Biomedical Engineering.

[12]  A. Stogryn,et al.  Equations for Calculating the Dielectric Constant of Saline Water (Correspondence) , 1971 .

[13]  RF ablation at audio frequencies preferentially targets tumor - a finite element study , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[14]  Thomas P. Ryan,et al.  Finite-element model for endometrial ablation systems , 1998, Photonics West - Biomedical Optics.

[15]  S. Fosko,et al.  Electrosurgery and cardiac devices. , 1997, Journal of the American Academy of Dermatology.

[16]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[17]  J. Svendsen,et al.  Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. , 1999, Circulation.

[18]  Norma Harrison,et al.  Technology management , 2001 .

[19]  B. Hutchisson,et al.  Electrosurgical safety. , 1998, AORN journal.

[20]  Jie Zhang,et al.  Noncontact radio-frequency ablation for obtaining deeper lesions , 2003, IEEE Transactions on Biomedical Engineering.

[21]  S. Baldwin,et al.  A Heat Transfer Model of Thermal Balloon Endometrial Ablation , 2001, Annals of Biomedical Engineering.

[22]  P Ruggera,et al.  CDRH RF phantom for hyperthermia systems evaluations. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[23]  Hong Cao,et al.  Three-dimensional finite-element analyses for radio-frequency hepatic tumor ablation , 2002, IEEE Trans. Biomed. Eng..

[24]  F. Duck Physical properties of tissue , 1990 .

[25]  S. Goldberg,et al.  Radiofrequency tumor ablation: principles and techniques. , 2001, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[26]  Gerhard J. Mueller,et al.  Interstitial bipolar rf-thermotherapy (RFITT): therapy planning by computer simulation and MRI monitoring--a new concept for minimally invasive procedures , 1998, Photonics West - Biomedical Optics.