Experimental evaluation of a 2D and 3D electron pencil beam algorithm

Verification of electron beam treatment-planning algorithms in the presence of heterogeneities can be very difficult. Using controlled geometries to minimise physical uncertainties in geometric alignment and composition, a large number of measurements were made to test the performance of a 2D and 3D electron pencil beam algorithm. A Therados RFA-3 beam-scanning system interfaced to a microcomputer was used to measure the dose distributions. The geometric arrangement consisted of single and double rods 1 cm in diameter situated just below the surface of a unit density phantom. The electron densities (relative to water) of the rods ranged from 2.12 (aluminium) to 1.29 (soft bone analogue), and their length could be varied between 1 cm and 10 cm. Measured isodose distributions beyond the inhomogeneities were compared with those predicted theoretically. Calculations were performed on a VAX-11/780 using 2D and 3D implementations of the Hogstrom electron pencil beam algorithm. The authors report on the nature of this 3D implementation and assess the magnitude of discrepancies between calculation and measurement for 10 MeV and 18 MeV electron beams, and for the variety of phantom compositions and geometries identified above.

[1]  MONTE CARLO CALCULATIONS OF ELECTRON BEAMS IN STANDARD DOSE PLANNING GEOMETRIES. , 1984 .

[2]  D. Perry,et al.  A model for calculating the effects of small inhomogeneities on electron beam dose distributions. , 1979, Medical physics.

[3]  D E Mellenberg,et al.  Dosimetric evaluation of a pencil-beam algorithm for electrons employing a two-dimensional heterogeneity correction. , 1984, International journal of radiation oncology, biology, physics.

[4]  J W Scrimger,et al.  Acquisition and display of radiation dose distributions using microcomputer technology. , 1988, Medical physics.

[5]  P. Storchi,et al.  The in-air scattering of clinical electron beams as produced by accelerators with scanning beams and diaphragm collimators. , 1987, Physics in medicine and biology.

[6]  I. Lax Accuracy in clinical electron beam dose planning using pencil beam algorithms. , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  P. Almond,et al.  Electron beam dose calculations , 1981, Physics in medicine and biology.

[8]  J. Cygler,et al.  Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations. , 1987, Physics in medicine and biology.

[9]  D Jette,et al.  Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory. , 1988, Medical physics.

[10]  D. J. Perry On the penetration of fast charged particles. , 1988, Radiation research.

[11]  K R Shortt,et al.  Electron beam dose distributions near standard inhomogeneities , 1986 .

[12]  I. Lax Inhomogeneity corrections in electron-beam dose planning. Limitations with the semi-infinite slab approximation. , 1986, Physics in medicine and biology.