Poorly operated air conditioning and mechanical ventilation (ACMV) system might cause significant Sick Building Syndrome (SBS) symptoms and thermal discomfort in the hot and humid climate. This study presents our investigations on the prevalence of SBS symptoms and thermal comfort in offices in Singapore via two approaches including: (1) the onsite objective monitoring and questionnaire-based investigation under normal ACMV practices, and (2) the online survey with occupants in controlled indoor temperatures. The results indicate that the prevalence of individual SBS symptoms is lower than the similar studies in other geographic regions. Overcooling seems to be the domineering complaint in the local context and the occupants seem to prefer higher indoor temperature. As such, human behavioral adjustments such as adding clothing happen quite frequently. Moreover, the data also suggests that cultural traits might skew the survey results, especially in certain subjective aspects regarding the satisfactory level and comfort. To sum up, the prevalence of SBS symptoms are generally acceptable in current local context. However, due to the hot and humid ambient environment, traditional ACMV system with vapor compression refrigerant tends to trigger the overcooling issue in relation to the sensible and latent heat. It is invaluable to advance our understanding of the relationships between the ACMV system, human behavioral adjustments, and building energy consumptions in the tropical region.

[1]  K. F. Fong,et al.  Effect of neutral temperature on energy saving of centralized air-conditioning systems in subtropical Hong Kong , 2010 .

[2]  R. de Dear,et al.  Thermal comfort in practice. , 2004 .

[3]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[4]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[5]  K. Mui,et al.  Neutral temperature in subtropical climates—A field survey in air-conditioned offices , 2007 .

[6]  W. Fisk,et al.  Summary of human responses to ventilation. , 2004, Indoor air.

[7]  M Orme,et al.  Energy and ventilation , 1998 .

[8]  K.W.D. Cheong,et al.  Development and application of an indoor air quality audit to an air-conditioned building in Singapore , 2001 .

[9]  E Ery Djunaedy,et al.  Thermal comfort study of an air-conditioned lecture theatre in the tropics , 2003 .

[10]  M J Mendell,et al.  Quantitative relationship of sick building syndrome symptoms with ventilation rates. , 2009, Indoor air.

[11]  R. Dear,et al.  Thermal adaptation in the built environment: a literature review , 1998 .

[12]  D. A. McIntyre,et al.  Chamber studies—reductio ad absurdum? , 1982 .

[13]  J. Samet,et al.  Ventilation rates and health: multidisciplinary review of the scientific literature. , 2011, Indoor air.

[14]  Gail Brager,et al.  The adaptive model of thermal comfort and energy conservation in the built environment. , 2001 .

[15]  N. Eriksson,et al.  Baseline prevalence of symptoms related to indoor environment , 2006, Scandinavian journal of public health.

[16]  Dawn Tharr Case Studies: Sick Building Syndrome: Factors Associated with Employee-Reported Symptoms , 1992 .

[17]  Francisco Radler de Aquino Neto,et al.  Symptoms prevalence among office workers of a sealed versus a non-sealed building: associations to indoor air quality. , 2009, Environment international.

[18]  Ruey Lung Hwang,et al.  Field Survey on Human Thermal Comfort Reports in Air-ConditionedOffices in Taiwan , 2007 .

[19]  J M Mur,et al.  Sick-building symptoms in office workers in northeastern France: a pilot study , 1998, International archives of occupational and environmental health.

[20]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[21]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[22]  J D Spengler,et al.  Evaluating building-related symptoms using the US EPA BASE study results. , 2008, Indoor air.

[23]  J. Myers,et al.  Influences on sick building syndrome symptoms in three buildings. , 1995, Social science & medicine.

[24]  K. Goh,et al.  Epidemiology of sick building syndrome and its associated risk factors in Singapore. , 1998, Occupational and environmental medicine.

[25]  W O Phoon,et al.  The Thermal Comfort of Sedentary Workers , 1987, Asia-Pacific journal of public health.

[26]  R. J. Dear,et al.  Thermal comfort in the humid tropics: Field experiments in air conditioned and naturally ventilated buildings in Singapore , 1991 .

[27]  J. F. Nicol,et al.  The validity of ISO-PMV for predicting comfort votes in every-day thermal environments , 2002 .

[28]  Wan Ki Chow,et al.  Sick building syndrome—A case study , 1991 .

[29]  C A Pickering,et al.  The sick building syndrome: prevalence studies. , 1984, British medical journal.

[30]  Wei Yang,et al.  Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China , 2008, International journal of biometeorology.

[31]  Dan Norbäck,et al.  Sick building syndrome in relation to air exchange rate, CO2, room temperature and relative air humidity in university computer classrooms: an experimental study , 2008, International archives of occupational and environmental health.

[32]  John Burnett,et al.  Large-scale survey of thermal comfort in office premises in Hong Kong , 1998 .

[33]  K. T. Goh,et al.  Sick-building syndrome in a tropical city , 1996, The Lancet.

[34]  P. Fanger,et al.  The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity. , 2000, Indoor air.

[35]  van J Joost Hoof,et al.  Forty years of Fanger’s model of thermal comfort: comfort for all? , 2008 .

[36]  Mukesh Khare,et al.  Sick building syndrome—A case study in a multistory centrally air-conditioned building in the Delhi City , 2007 .

[37]  K. Goh,et al.  Sick building syndrome: an emerging stress-related disorder? , 1997, International journal of epidemiology.