Tumor motion ranges due to respiration and respiratory motion characteristics

Many soft-tissue tumors targeted with extracranial SRS move during respiration. New imaging technologies, motion compensation strategies, and treatment planning algorithms are being developed which enable tracking and treatment of moving tumors in real-time. For this chapter we reviewed the literature to determine known tumor motion amplitudes for lung, liver, and pancreas. Then we analyzed predicted tumor motion for 36 patients and 117 treatment fractions that were previously saved in CyberKnife® (Accuray Incorporated, Sunnyvale, CA) treatment logfiles. These represent 27 tumors in the lung (16 upper lung, 4 middle lung, 7 lower lung) and 9 pancreas patients. For each treatment, the location of the target at end inspiration and end expiration was determined in the patient coordinate system. The origin of the patient coordinate system is at the center of mass of the fiducials as marked on the simulation CT, +x is patient inferior, +y patient left, and +z anterior in a right-handed coordinate system. The mean and variance of respiratory cycle extrema positions were calculated using a program written in MatLab code. Observed motion ranges for all sites except pancreas agree very well with the literature. The largest motion amplitudes of up to 38.7 mm were observed in the lower lung. Twenty-five percent of tumors in the upper lung could have been treated without Synchrony® (Accuray Incorporated, Sunnyvale, CA) with a PTV margin of 2 mm, because the uncertainty is in the range of the technical tracking accuracy of Synchrony of 1.5 mm. Possible causes of large fluctuations around the mean motion could be fiducial tracking errors or irregular breathing. We concluded that a subset of all patients could have been treated using skeletal structure tracking, rather than implanted fiducials, and a PTV margin in the range of the stated tracking accuracy for Synchrony. Defining meaningful parameters to characterize the effects of free breathing is part of ongoing research, since published data from non-dynamic SBRT is limited to short fluoroscopic studies or Cine-CT. The results can be transferred to other treatment modalities to determine PTV margins in standard external beam treatments as well as defining the PTV in the third dimension for 2D motion compensation [1].

[1]  J. Adler,et al.  An Anthropomorphic Phantom Study of the Accuracy of CyberKnife Spinal Radiosurgery , 2004, Neurosurgery.

[2]  Kevin Cleary,et al.  A robotic 3-D motion simulator for enhanced accuracy in CyberKnife stereotactic radiosurgery , 2004, CARS.

[3]  J. Haaga,et al.  Respiratory movement of the pancreas: an ultrasonic study. , 1984, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  T. Bortfeld,et al.  How much margin reduction is possible through gating or breath hold? , 2005, Physics in medicine and biology.

[5]  David Sarrut,et al.  Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[6]  A. Quinn CyberKnife: a robotic radiosurgery system. , 2002, Clinical journal of oncology nursing.

[7]  Zbigniew Petrovich,et al.  The CyberKnife stereotactic radiosurgery system: description, installation, and an initial evaluation of use and functionality. , 2003, Neurosurgery.

[8]  John Wong,et al.  Accuracy of a wireless localization system for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[9]  M J Murphy,et al.  The Cyberknife: a frameless robotic system for radiosurgery. , 1997, Stereotactic and functional neurosurgery.

[10]  Christopher G Willett,et al.  Quantification of respiration-induced abdominal tumor motion and its impact on IMRT dose distributions. , 2004, International journal of radiation oncology, biology, physics.

[11]  Uwe Oelfke,et al.  Online correction for respiratory motion: evaluation of two different imaging geometries , 2005, Physics in medicine and biology.

[12]  Shinichi Shimizu,et al.  Intrafractional tumor motion: lung and liver. , 2004, Seminars in radiation oncology.

[13]  Koichi Yamazaki,et al.  Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[14]  I. Suramo,et al.  Cranio-Caudal Movements of the Liver, Pancreas and Kidneys in Respiration , 1984, Acta radiologica: diagnosis.

[15]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[16]  Patrick A Kupelian,et al.  Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[17]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[18]  Cedric X. Yu,et al.  Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study , 2005, Physics in medicine and biology.

[19]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[20]  Y Suh,et al.  A feasibility study on the prediction of tumour location in the lung from skin motion. , 2004, The British journal of radiology.

[21]  Wilfred Sewchand,et al.  Marker seed migration in prostate localization. , 2002, International journal of radiation oncology, biology, physics.

[22]  Thomas Flohr,et al.  Four-dimensional multislice computed tomography for determination of respiratory lung tumor motion in conformal radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[23]  Eric C Ford,et al.  Measurement of lung tumor motion using respiration-correlated CT. , 2004, International journal of radiation oncology, biology, physics.

[24]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[25]  Achim Schweikard,et al.  Respiration tracking in radiosurgery. , 2004, Medical physics.

[26]  Barbara Dobler,et al.  Frameless Stereotactic Radiosurgery of a Solitary Liver Metastasis Using Active Breathing Control and Stereotactic Ultrasound , 2006, Strahlentherapie und Onkologie.

[27]  Suresh Senan,et al.  Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? , 2003, International journal of radiation oncology, biology, physics.

[28]  Herbert Cattell,et al.  Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system. , 2006, International journal of radiation oncology, biology, physics.