Non-Invasive Estimation of Systolic Blood Pressure and Diastolic Blood Pressure Using Photoplethysmograph Components

Purpose Photoplethysmography (PPG) is a noninvasive optical technology that detects changes in blood volume in the vascular system. This study aimed to investigate the possibilities of monitoring the cardiovascular system status by using PPG. Materials and Methods Forced hemodynamic changes were induced using cardiac stimulants; dopamine and epinephrine, and PPG components were recorded by a noninvasive method at the peripheral blood vessels. The results were compared among 6 dogs. Endotracheal intubation was performed after an intramuscular injection of 25 mg/kg ketamine sulfate, and anesthesia was maintained with 2% enflurane. After stabilizing the animals for 15 min, 16 mg/mL diluted dopamine was injected into a vein for 2 min at 20 µg/kg· min-1 by using an infusion pump. Thereafter, the infusion pump was stopped, and 1 mg epinephrine was injected intravenously. Fluid administration was controlled to minimize preload change in blood pressure. Results After stimulant administration, systolic blood pressure (SBP) and diastolic blood pressures (DBP) increased. The direct current (DC) component, which reflects changes in blood volume, decreased while the alternating current (AC) component, which reflects changes in vascular compliance and resistance, increased. The correlation coefficient between SBP and the foot of the DC component was 0.939 (p < 0.01), while it was 0.942 (p < 0.01) for DBP and the peak of the DC component. The AC component could predict the increase in vascular resistance from a stable pulse blood volume, even with increased pulse pressure. Conclusions These results support the possibility that PPG components may be used for easy and noninvasive measurement of hemodynamic changes in the cardiovascular system.

[1]  D. S. Luciano,et al.  Human Physiology: The Mechanism of Body Function , 1975 .

[2]  A Murray,et al.  Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes , 2000, Physiological measurement.

[3]  R. Cohen,et al.  Hemodynamic regulation: investigation by spectral analysis. , 1985, The American journal of physiology.

[4]  D. Goldstein,et al.  A test of the "epinephrine hypothesis" in humans. , 1999, Hypertension.

[5]  Hartmut Ewald,et al.  An optical device to measure blood components by a photoplethysmographic method , 2005 .

[6]  J. Vincent,et al.  Effects of dopamine, norepinephrine, and epinephrine on the splanchnic circulation in septic shock: which is best? , 2003, Critical care medicine.

[7]  D. Annane,et al.  Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update , 2004, Critical care medicine.

[8]  M. Nitzan,et al.  Simultaneous Measurement of the Photoplethysmographic Signal Variability in the Right and Left Hands , 1998, Lasers in Medical Science.

[9]  A. Hill,et al.  The Velocity of the Pulse Wave in Man , 1922 .

[10]  H. Asada,et al.  Calibration of the Photoplethysmogram to Arterial Blood Pressure: Capabilities and Limitations for Continuous Pressure Monitoring , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[11]  M. Nitzan,et al.  Verylow frequency variability in arterial blood pressure and blood volume pulse , 2006, Medical & Biological Engineering & Computing.

[12]  P. Ott,et al.  The effect of increasing blood pressure with dopamine on systemic, splanchnic, and lower extremity hemodynamics in patients with acute liver failure. , 1999, Scandinavian journal of gastroenterology.

[13]  G D Pinna,et al.  Estimation of arterial blood pressure variability by spectral analysis: comparison between Finapres and invasive measurements. , 1996, Physiological measurement.

[14]  T. Obara,et al.  The role of epinephrine, norepinephrine, and dopamine in blood pressure disturbances in patients with pheochromocytoma , 1992, World Journal of Surgery.

[15]  T. Ohkubo,et al.  Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: their relationship and associating factors , 2002, Journal of hypertension.

[16]  G. Lip,et al.  ABC of hypertension: The pathophysiology of hypertension. , 2001, BMJ.

[17]  M. Murphy,et al.  Dopamine receptor agonists in cardiovascular medicine. , 1991, Trends in cardiovascular medicine.

[18]  J. Griffin Human Physiology, The Mechanisms of Body Function , 1971 .

[19]  J. Michael Textbook of Medical Physiology , 2005 .

[20]  Daniel W. Jones,et al.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. , 2005, Hypertension.

[21]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[22]  P. King,et al.  Design Of Pulse Oximeters , 1998, IEEE Engineering in Medicine and Biology Magazine.

[23]  L. Nilsson,et al.  Respiratory variations in the reflection mode photoplethysmographic signal. Relationships to peripheral venous pressure , 2003, Medical and Biological Engineering and Computing.

[24]  K H Wesseling Finger arterial pressure measurement with Finapres. , 1996, Zeitschrift fur Kardiologie.

[25]  W. Elliott,et al.  Dopamine and dopamine receptor agonists in cardiovascular therapy , 1990, Critical care medicine.

[26]  G. Kuchel,et al.  Peripheral Dopamine in Pathophysiology of Hypertension: Interaction With Aging and Lifestyle , 1991, Hypertension.

[27]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[28]  J. Shepherd,et al.  Responses of the Superficial Limb Veins of the Dog to Changes in Temperature , 1968, Circulation research.

[29]  R. Orglmeister,et al.  The principles of software QRS detection , 2002, IEEE Engineering in Medicine and Biology Magazine.

[30]  Wesseling Kh Finger arterial pressure measurement with Finapres. , 1996 .