Motion artifacts in CT scans: a study by computer simulation and mechanical phantom

Computed tomography (CT) is one of the most important tools in the diagnosis of thoracic tumors. However, during the scanning process, respiratory motion causes changes in the position and shape of the tumor, creating motion artifacts in the CT scan. This can lead to misdiagnosis of the size and position of the tumor, and can affect the effectiveness of treatment. This study develops a computer model of the movement of the thorax, and simulates the movement of a lung tumor caused by breathing during a CT scan. We show that adjusting the CT slice thickness is sufficient to determine the center of displacement and maximum displacement of a tumor during normal breathing. This model can be applied in the clinical diagnostic use of CT equipment. It will assist in finding the position of lung tumors from motion artifacts in CT scans. The target margin for treatment can thus be defined more accurately, so that appropriate doses of radiation can be applied to the target area, and irradiation of healthy tissue avoided.

[1]  Jeffrey A. Fessler,et al.  Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image Registration , 2007, IEEE Transactions on Medical Imaging.

[2]  R. E. Wallace,et al.  Seminars in Radiation Oncology , 1993 .

[3]  Freek J. Beekman,et al.  Accelerated simulation of cone beam X-ray scatter projections , 2004, IEEE Transactions on Medical Imaging.

[4]  Jeffrey A. Fessler,et al.  Fast Monotonic Algorithms for Transmission Tomography , 1999, IEEE Trans. Medical Imaging.

[5]  J. Overgaard Radiotherapy and Oncology comes of age. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  G. Ceresoli,et al.  Use of dose-volume histograms and biophysical models to compare 2D and 3D irradiation techniques for non-small cell lung cancer. , 1999, The British journal of radiology.

[7]  J. Armstrong,et al.  The impact of three-dimensional radiation on the treatment of non-small cell lung cancer. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  E. W. Shrigley Medical Physics , 1944, British medical journal.

[9]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[10]  Fang-Fang Yin,et al.  A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  Isabelle M Gagné,et al.  The impact of tumor motion upon CT image integrity and target delineation. , 2004, Medical physics.

[12]  D. Feng,et al.  IEEE transactions on information technology in biomedicine: special issue on advances in clinical and health-care knowledge management , 2005 .

[13]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[14]  Hak Choy,et al.  International Journal of Radiation Oncology Biology Physics: Introduction , 2004 .

[15]  Max A. Viergever,et al.  Computer-aided diagnosis in chest radiography: a survey , 2001, IEEE Transactions on Medical Imaging.

[16]  IEEE TRANSACTIONS ON CORE VLSI IEEE TRANSACTIONS ON IMAGE PROCESSING IEEE TRANSACTIONS ON DIGITAL SYSTEM DESIGN IEEE TRANSACTIONS ON TESTING IEEE TRANSACTIONS ON COMMUNICATION IEEE TRANSACTIONS ON LOW POWER VLSI , 2010 .

[17]  J. Escolar,et al.  Airway and lung parenchyma morphology during the respiratory cycle. , 2007, Histology and histopathology.

[18]  Jürgen Weese,et al.  Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery , 1997, IEEE Transactions on Information Technology in Biomedicine.

[19]  Michael Unser,et al.  Optimization of mutual information for multiresolution image registration , 2000, IEEE Trans. Image Process..

[20]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.