Carbon monofilament electrodes for unit recording and functional MRI in same subjects

&NA; Extracellular electrophysiology and functional MRI are complementary techniques that provide information about cellular and network‐level neural activity, respectively. However, electrodes for electrophysiology are typically made from metals, which cause significant susceptibility artifacts on MR images. Previous work has demonstrated that insulated carbon fiber bundle electrodes reduce the volume of magnetic susceptibility artifacts and can be used to record local field potentials (LFP), but the relatively large diameter of the probes make them unsuitable for multi‐ and single‐unit recordings. Although single carbon fiber electrodes have recently been used to record single‐unit activity, these probes require modifications in order to aid insertion and the use of these probes in fMRI has yet to be validated. Therefore, there is a need for a single‐carbon fiber electrode design that (1) minimizes the volume of the susceptibility artifact, (2) can record from a wide frequency band that includes LFP and multi‐ and single‐unit recording, and (3) is practical to insert without additional modifications. Here, we demonstrate that carbon‐fiber electrodes made from single carbon monofilaments (35 &mgr;m in diameter) meet all of these criteria. Carbon monofilament electrodes modified with the conductive polymer poly(3,4‐ethylenedioxythiophene) (PEDOT) have lower impedances and higher signal‐to‐noise ratio recordings than platinum‐iridium electrodes, a current gold standard for chronic single‐unit recording. Furthermore, these probes distort a significantly smaller volume of voxels compared to tungsten and platinum‐iridium electrodes in agarose phantom and in vivo MR images, leading to higher contrast‐to‐noise ratio in regions proximal to the electrode implantation site during fMRI. Collectively, this work establishes that carbon monofilaments are a practical choice for combined electrophysiology‐fMRI experiments.

[1]  E. Halgren,et al.  Spatiotemporal mapping of brain activity by integration of multiple imaging modalities , 2001, Current Opinion in Neurobiology.

[2]  Sam Kassegne,et al.  A novel pattern transfer technique for mounting glassy carbon microelectrodes on polymeric flexible substrates , 2016 .

[3]  U. Knoblich,et al.  Optogenetic drive of neocortical pyramidal neurons generates fMRI signals that are correlated with spiking activity , 2013, Brain Research.

[4]  Ji-Kyung Choi,et al.  Exogenous contrast agent improves sensitivity of gradient‐echo functional magnetic resonance imaging at 9.4 T , 2004, Magnetic resonance in medicine.

[5]  G. Paxinos,et al.  The Rat Brain in Stereotaxic Coordinates , 1983 .

[6]  Jia Liu,et al.  Comparison of fMRI analysis methods for heterogeneous BOLD responses in block design studies , 2017, NeuroImage.

[7]  Nikos K Logothetis,et al.  On the nature of the BOLD fMRI contrast mechanism. , 2004, Magnetic resonance imaging.

[8]  Z. Israel,et al.  2 Principles of Extracellular Single-Unit Recording , 2004 .

[9]  Jesse Jackson,et al.  Functional brain mapping at 9.4T using a new MRI‐compatible electrode chronically implanted in rats , 2009, Magnetic resonance in medicine.

[10]  E. Jeong,et al.  Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies. , 1998, AJR. American journal of roentgenology.

[11]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[12]  Michael D Joseph,et al.  Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes , 2011, Journal of neural engineering.

[13]  Paras R. Patel,et al.  Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. , 2012, Nature materials.

[14]  Robert L. White,et al.  An Evaluation of the Resistance to Electrolysis of Metals for Use in Biostimulation Microprobes , 1974 .

[15]  S. Cartmell,et al.  Conductive polymers: towards a smart biomaterial for tissue engineering. , 2014, Acta biomaterialia.

[16]  M. Ward,et al.  Toward a comparison of microelectrodes for acute and chronic recordings , 2009, Brain Research.

[17]  Santiago Canals,et al.  Frequency-Dependent Gating of Hippocampal-Neocortical Interactions. , 2016, Cerebral cortex.

[18]  L. Geddes,et al.  Criteria for the Selection of Materials for Implanted Electrodes , 2003, Annals of Biomedical Engineering.

[19]  David C. Martin,et al.  Layered carbon nanotube-polyelectrolyte electrodes outperform traditional neural interface materials. , 2009, Nano letters.

[20]  C. Koch,et al.  The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes , 2012, Nature Reviews Neuroscience.

[21]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[22]  Luciano Fadiga,et al.  Highly Stable Glassy Carbon Interfaces for Long-Term Neural Stimulation and Low-Noise Recording of Brain Activity , 2017, Scientific Reports.

[23]  Yakun Ma,et al.  Experimental evaluation of neural probe's insertion induced injury based on digital image correlation method. , 2016, Medical physics.

[24]  Huanan Zhang,et al.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings , 2015, Journal of neural engineering.

[25]  Bin He,et al.  Electrophysiological Imaging of Brain Activity and Connectivity—Challenges and Opportunities , 2011, IEEE Transactions on Biomedical Engineering.

[26]  J. Mandeville,et al.  Vascular filters of functional MRI: Spatial localization using BOLD and CBV contrast , 1999, Magnetic resonance in medicine.

[27]  Takeshi Ogawa,et al.  A mini-cap for simultaneous EEG and fMRI recording in rodents , 2011, NeuroImage.

[28]  Nigel H Lovell,et al.  Substrate dependent stability of conducting polymer coatings on medical electrodes. , 2012, Biomaterials.

[29]  R. Quian Quiroga,et al.  Unsupervised Spike Detection and Sorting with Wavelets and Superparamagnetic Clustering , 2004, Neural Computation.

[30]  Yusuke Tsutsumi,et al.  Three-dimensional quantification of susceptibility artifacts from various metals in magnetic resonance images. , 2013, Acta biomaterialia.

[31]  Karen L. Smith,et al.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion , 2006, Journal of neural engineering.

[32]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[33]  Rami K. Niazy,et al.  Removal of FMRI environment artifacts from EEG data using optimal basis sets , 2005, NeuroImage.

[34]  Changqing Jiang,et al.  Artifact properties of carbon nanotube yarn electrode in magnetic resonance imaging , 2013, Journal of neural engineering.

[35]  A. Zerbi,et al.  Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art , 2009, European Spine Journal.

[36]  J. Schouenborg,et al.  The density difference between tissue and neural probes is a key factor for glial scarring , 2013, Scientific Reports.

[37]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[38]  Euisik Yoon,et al.  State-of-the-art MEMS and microsystem tools for brain research , 2017, Microsystems & Nanoengineering.

[39]  Lei Ding,et al.  Integration of EEG/MEG with MRI and fMRI , 2006, IEEE Engineering in Medicine and Biology Magazine.

[40]  William A Liberti,et al.  A carbon-fiber electrode array for long-term neural recording , 2013, Journal of neural engineering.

[41]  Ryan Chamberlain,et al.  Simultaneous fMRI and local field potential measurements during epileptic seizures in medetomidine‐sedated rats using raser pulse sequence , 2010, Magnetic resonance in medicine.

[42]  Mark W Meisel,et al.  Absolute magnetic susceptibility of rat brain tissue , 2014, Magnetic resonance in medicine.

[43]  D. Hubel Tungsten Microelectrode for Recording from Single Units. , 1957, Science.

[44]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[45]  David C. Martin,et al.  Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays , 2003 .

[46]  Daniel L. Albaugh,et al.  Robust deep brain stimulation functional MRI procedures in rats and mice using an MR‐compatible tungsten microwire electrode , 2015, Magnetic resonance in medicine.

[47]  B. Rosen,et al.  Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation , 1998, Magnetic resonance in medicine.

[48]  George M. Whitesides,et al.  Fabrication of glassy carbon microstructures by pyrolysis of microfabricated polymeric precursors , 1997 .

[49]  M L Wolbarsht,et al.  Glass Insulated Platinum Microelectrode , 1960, Science.

[50]  Jin Hyung Lee,et al.  High-throughput optogenetic functional magnetic resonance imaging with parallel computations , 2013, Journal of Neuroscience Methods.

[51]  G. Buzsáki Large-scale recording of neuronal ensembles , 2004, Nature Neuroscience.

[52]  C. Mathiesen,et al.  Modification of activity‐dependent increases of cerebral blood flow by excitatory synaptic activity and spikes in rat cerebellar cortex , 1998, The Journal of physiology.

[53]  N. Logothetis,et al.  Neurophysiological investigation of the basis of the fMRI signal , 2001, Nature.

[54]  Bianca Jupp,et al.  MRI compatible electrodes for the induction of amygdala kindling in rats , 2006, Journal of Neuroscience Methods.

[55]  C. Segebarth,et al.  Identifying Neural Drivers with Functional MRI: An Electrophysiological Validation , 2008, PLoS biology.

[56]  A. D. de Crespigny,et al.  High-Resolution Functional Magnetic Resonance Imaging of the Rat Brain: Mapping Changes in Cerebral Blood Volume Using Iron Oxide Contrast Media , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[57]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[58]  Ben A. Duffy,et al.  MRI compatible optrodes for simultaneous LFP and optogenetic fMRI investigation of seizure-like afterdischarges , 2015, NeuroImage.

[59]  Klas H. Pettersen,et al.  Modeling the Spatial Reach of the LFP , 2011, Neuron.

[60]  K. Barai,et al.  Scanning electron microscopy studies of PEDOT prepared by various electrochemical routes , 2008 .

[61]  Frank Bihari,et al.  Real‐time display of artifact‐free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy , 2005, Magnetic resonance in medicine.

[62]  Justin C. Sanchez,et al.  Corrosion of tungsten microelectrodes used in neural recording applications , 2011, Journal of Neuroscience Methods.