Intelligent controlled shunt active power filter for voltage and current harmonic compensation in microgrid system

ABSTRACT An integrated microgrid with a novel shunt active power filter (APF) using Elman neural network (ENN) is proposed in this study. The microgrid consists of a storage system, a photovoltaic (PV) system, the shunt APF, a linear load, and a nonlinear load. Moreover, the master/slave control algorithm is adopted in the microgrid. The storage system, which is considered as the master unit, is adopted to control the active and reactive power outputs (P/Q control) in grid-connected mode and the voltage and frequency of the microgrid (V/f control) in islanded mode. Furthermore, the PV system is considered as the slave unit to implement P/Q control in both grid-connected and islanded modes. In addition, the proposed shunt APF possesses dual functions of voltage and current harmonic compensation for microgrid under voltage harmonic propagation and nonlinear load to reduce the voltage and current total harmonic distortions (THD) effectively. Additionally, an ENN controller is adopted in the proposed shunt APF to improve the transient and steady-state responses of DC-link voltage during the switching between the grid-connected mode and islanded mode. Finally, some simulation results are provided to verify the feasibility and the effectiveness of the integrated microgrid with the intelligent controlled shunt APF.

[1]  Sanjib Kumar Panda,et al.  Lyapunov Function-Based Current Controller to Control Active and Reactive Power Flow From a Renewable Energy Source to a Generalized Three-Phase Microgrid System , 2013, IEEE Transactions on Industrial Electronics.

[2]  Yung-Ruei Chang,et al.  Active islanding detection method using d-axis disturbance signal injection with intelligent control , 2013 .

[3]  Engin Özdemir,et al.  Synchronous-Reference-Frame-Based Control Method for UPQC Under Unbalanced and Distorted Load Conditions , 2011, IEEE Transactions on Industrial Electronics.

[4]  Zhuo Bin Development of Hardware-in-the-loop Simulation System for Powertrain Control Module of PEV , 2004 .

[5]  Hak-Man Kim,et al.  Cooperative Control Strategy of Energy Storage System and Microsources for Stabilizing the Microgrid during Islanded Operation , 2010, IEEE Transactions on Power Electronics.

[6]  Mang-Hui Wang,et al.  Partial discharge pattern recognition of current transformers using an ENN , 2005, IEEE Transactions on Power Delivery.

[7]  Marco Rivera,et al.  Improved Active Power Filter Performance for Renewable Power Generation Systems , 2014, IEEE Transactions on Power Electronics.

[8]  Rong-Jong Wai,et al.  Fuzzy neural network position controller for ultrasonic motor drive using push-pull DC-DC converter , 1999 .

[9]  Hirofumi Akagi,et al.  Control and performance of a fully-digital-controlled shunt active filter for installation on a power distribution system , 2002 .

[10]  Faa-Jeng Lin,et al.  Active islanding detection method via current injection disturbance using Elman neural network , 2015 .

[11]  Hideaki Fujita,et al.  Dynamic Control and Analysis of DC-Capacitor Voltage Fluctuations in Three-Phase Active Power Filters , 2013, IEEE Transactions on Power Electronics.

[12]  H. Akagi,et al.  A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[13]  K. Wada,et al.  Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[14]  Hak-Man Kim,et al.  Development of Hardware In-the-Loop Simulation System for Testing Operation and Control Functions of Microgrid , 2010, IEEE Transactions on Power Electronics.

[15]  Jeffrey L. Elman,et al.  Finding Structure in Time , 1990, Cogn. Sci..

[16]  F. Blaabjerg,et al.  High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters , 2007, IEEE Transactions on Power Electronics.

[17]  Oriol Gomis-Bellmunt,et al.  Trends in Microgrid Control , 2014, IEEE Transactions on Smart Grid.

[18]  Andrew Kusiak,et al.  Optimization of Wind Turbine Performance With Data-Driven Models , 2010, IEEE Transactions on Sustainable Energy.

[19]  V. Khadkikar,et al.  Enhancing Electric Power Quality Using UPQC: A Comprehensive Overview , 2012, IEEE Transactions on Power Electronics.

[20]  Mohammad Shahidehpour,et al.  Integration of High Reliability Distribution System in Microgrid Operation , 2012, IEEE Transactions on Smart Grid.

[21]  Yan Li,et al.  Decoupled power control for an inverter based low voltage microgrid in autonomous operation , 2009, 2009 IEEE 6th International Power Electronics and Motion Control Conference.

[22]  Yinliang Xu,et al.  Distributed Optimal Resource Management Based on the Consensus Algorithm in a Microgrid , 2015, IEEE Transactions on Industrial Electronics.

[23]  Leonardo Bruno Garcia Campanhol,et al.  Application of shunt active power filter for harmonic reduction and reactive power compensation in three-phase four-wire systems , 2014 .

[24]  Hirofumi Akagi,et al.  Implementation and performance of automatic gain adjustment in a shunt-active filter for harmonic damping throughout a power distribution system , 2002 .

[25]  Faa-Jeng Lin,et al.  Improved differential evolution-based Elman neural network controller for squirrel-cage induction generator system , 2016 .

[26]  Q. Jiang,et al.  Energy Management of Microgrid in Grid-Connected and Stand-Alone Modes , 2013, IEEE Transactions on Power Systems.

[27]  Tanuja N. Date,et al.  Energy management in microgrid , 2017, 2017 International Conference on Computing Methodologies and Communication (ICCMC).