Sensitivity Analysis on the Impact Factors of the GSHP System Considering Energy Generation and Environmental Impact Using LCA

The world is facing a crisis due to energy depletion and environmental pollution. The ground source heat pump (GSHP) system, the most efficient new/renewable energy (NRE) system that can reduce the load of heating/cooling equipment in a building, can be used to address this crisis. Designers and contractors have implemented such systems depending on their experience, although there are many factors that affect the performance of the GSHP system. Therefore, this study aimed to conduct a sensitivity analysis on the impact factors in terms of energy generation and environmental impact. This study was conducted as follows: (i) collecting the impact factors that affect the GSHP system’s performance; (ii) establishing the GSHP system’s scenarios with the impact factors; (iii) determining the methodology and calculation tool to be used for conducting sensitivity analysis; and (iv) conducting sensitivity analysis on the impact factors of the GSHP system in terms of energy generation and environmental impact using life cycle assessment. The results of this study can be used: (i) to establish the optimal design strategy for different application fields and different seasons; and (ii) to conduct a feasibility study on energy generation and environmental impact at the level of the life cycle.

[1]  Daehie Hong,et al.  Performance evaluation and modeling of a hybrid cooling system combining a screw water chiller with a ground source heat pump in a building , 2010 .

[2]  Taehoon Hong,et al.  Framework for the implementation of a new renewable energy system in an educational facility , 2013 .

[3]  武彦 福島 持続可能性(Sustainability)の要件 , 2006 .

[4]  Taehoon Hong,et al.  Energy-Saving Techniques for Reducing CO 2 Emissions in Elementary Schools , 2012 .

[5]  C. K. Lee,et al.  Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation , 2011 .

[6]  Arif Hepbasli,et al.  Performance evaluation of a vertical ground‐source heat pump system in Izmir, Turkey , 2002 .

[7]  Saltelli Andrea,et al.  Global Sensitivity Analysis: The Primer , 2008 .

[8]  Joseph C. Lam,et al.  Sensitivity analysis of energy performance of office buildings , 1996 .

[9]  Taehoon Hong,et al.  Benchmarks as a tool for free allocation through comparison with similar projects: Focused on multi-family housing complex , 2014 .

[10]  V. Ismet Ugursal,et al.  Modeling of end-use energy consumption in the residential sector: A review of modeling techniques , 2009 .

[11]  Hyo Seon Park,et al.  Development of a new energy efficiency rating system for existing residential buildings , 2014 .

[12]  Karlynn Cory,et al.  Feed-in Tariff Policy: Design, Implementation, and RPS Policy Interactions , 2009 .

[13]  Jin-Yong Lee,et al.  Current status of ground source heat pumps in Korea , 2009 .

[14]  Randall S. Jones,et al.  Korea's Green Growth Strategy: Mitigating Climate Change and Developing New Growth Engines , 2011 .

[15]  Liu Yang,et al.  Sensitivity analysis and energy conservation measures implications , 2008 .

[16]  Mustafa Inalli,et al.  Modelling of a vertical ground coupled heat pump system by using artificial neural networks , 2009, Expert Syst. Appl..

[17]  Henrik Brohus,et al.  Application of sensitivity analysis in design of sustainable buildings , 2009 .

[18]  Chang-Taek Hyun,et al.  A Study on the Development of a Cost Model Based on the Owner's Decision Making at the Early Stages of a Construction Project , 2010 .

[19]  Hyo Seon Park,et al.  A model for predicting the environmental impacts of educational facilities in the project planning phase , 2015 .

[20]  Elie Azar,et al.  A comprehensive analysis of the impact of occupancy parameters in energy simulation of office buildings , 2012 .

[21]  Judith Gurney BP Statistical Review of World Energy , 1985 .

[22]  Melissa A. Schilling,et al.  Technology S-Curves in Renewable Energy Alternatives: Analysis and Implications for Industry and Government. , 2009 .

[23]  Hyo Seon Park,et al.  An economic and environmental assessment for selecting the optimum new renewable energy system for educational facility , 2014 .

[24]  Arif Hepbasli,et al.  Experimental study of a closed loop vertical ground source heat pump system , 2003 .

[25]  Taehoon Hong,et al.  Maintenance management process for reducing CO 2 emission in shopping mall complexes , 2011 .

[26]  Per Lundqvist,et al.  Retrofitting a variable capacity heat pump to a ventilation heat recovery system : modeling and performance analysis , 2010 .

[27]  Hikari Fujii,et al.  Numerical simulation and sensitivity study of double-layer Slinky-coil horizontal ground heat exchangers , 2013 .

[28]  Sara Cosentino,et al.  Energy and exergy analysis of ground thermal energy storage: optimal charging time in different operating conditions , 2015 .

[29]  Taehoon Hong,et al.  An Environmental and Economic Assessment for Selecting the Optimal Ground Heat Exchanger by Considering the Entering Water Temperature , 2015 .

[30]  Taehoon Hong,et al.  LCC and LCCO2 analysis of green roofs in elementary schools with energy saving measures , 2012 .

[31]  Alessandro Casasso,et al.  Efficiency of closed loop geothermal heat pumps: A sensitivity analysis , 2014 .

[32]  Hyo Seon Park,et al.  Comparative analysis of decision-making methods for integrating cost and CO2 emission – focus on building structural design – , 2014 .

[33]  Hyo Seon Park,et al.  Estimation of the monthly average daily solar radiation using geographic information system and advanced case-based reasoning. , 2013, Environmental science & technology.

[34]  Taehoon Hong,et al.  Analysis of South Korea’s economic growth, carbon dioxide emission, and energy consumption using the Markov switching model , 2013 .

[35]  Hyo Seon Park,et al.  A GIS (geographic information system)-based optimization model for estimating the electricity generation of the rooftop PV (photovoltaic) system , 2014 .

[36]  Hiep V. Nguyen,et al.  A methodology and computerized approach for optimizing hybrid ground source heat pump system design , 2013 .

[37]  Yan Gao,et al.  Thermal performance and operation strategy optimization for a practical hybrid ground-source heat-pump system , 2014 .

[38]  Bo Nordell,et al.  Global warming’s impact on the performance of GSHP , 2011 .

[39]  Taehoon Hong,et al.  A decision support model for improving a multi-family housing complex based on CO2 emission from electricity consumption. , 2012, Journal of environmental management.

[40]  Sebastian Herkel,et al.  Energy and efficiency analysis of environmental heat sources and sinks: In-use performance , 2011 .

[41]  Andrea Saltelli,et al.  Sensitivity Analysis for Importance Assessment , 2002, Risk analysis : an official publication of the Society for Risk Analysis.

[42]  Clare Breidenich,et al.  The Kyoto Protocol to the United Nations Framework Convention on Climate Change , 1998, American Journal of International Law.

[43]  R. Bertani Geothermal power generation in the world 2010–2014 update report , 2016 .

[44]  Arif Hepbasli,et al.  Energy and exergy analysis of a ground source (geothermal) heat pump system , 2004 .

[45]  Adnan Khan,et al.  Development of a graph method for preliminary design of borehole ground-coupled heat exchanger in North Louisiana , 2015 .

[46]  Vajiheh Sabeti,et al.  Optimization of a novel combined cooling, heating and power cycle driven by geothermal and solar energies using the water/CuO (copper oxide) nanofluid , 2015 .

[47]  Taehoon Hong,et al.  Framework for the analysis of the potential of the rooftop photovoltaic system to achieve the net‐zero energy solar buildings , 2014 .

[48]  Sangyoub Lee,et al.  Production prediction of conventional and global positioning system–based earthmoving systems using simulation and multiple regression analysis , 2008 .

[49]  Unfccc Kyoto Protocol to the United Nations Framework Convention on Climate Change , 1997 .

[50]  Z. Fang,et al.  Efficiency of vertical geothermal heat exchangers in the ground source heat pump system , 2003 .

[51]  Pradeep K. Sahoo,et al.  Potential Reduction in CO2 Emission and Saving in Electricity by Ground Source Heat Pump System for Space Heating Applications - A Study on Northern Part of India , 2012 .

[52]  Dwain K. Butler,et al.  Crosshole seismic testing; procedures and pitfalls , 1981 .

[53]  Hyo Seon Park,et al.  Decision support model for establishing the optimal energy retrofit strategy for existing multi-family housing complexes , 2014 .

[54]  Hyo Seon Park,et al.  A program-level management system for the life cycle environmental and economic assessment of complex building projects , 2015 .

[55]  Makbul A.M. Ramli,et al.  Analysis of renewable energy feed-in tariffs in selected regions of the globe: Lessons for Saudi Arabia , 2015 .

[56]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[57]  Stanislaw Kajl,et al.  A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems , 2010 .

[58]  J. Spitler,et al.  Reference data sets for vertical borehole ground heat exchanger models and thermal response test ana , 2011 .

[59]  Xu Zhang,et al.  Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study , 2008 .

[60]  Juliana de Moraes Marreco,et al.  Perspectives for the expansion of new renewable energy sources in Brazil , 2013 .

[61]  Mustafa Inalli,et al.  Experimental thermal performance evaluation of a horizontal ground-source heat pump system , 2004 .