Failure analysis and dispatch optimization using phasor measurement units

Abstract The incorporation of the Phasor Measurement Units (PMU) allow the development of new tools, both for planning, failure analysis and operation in Power Systems (PS); as a result of that, it increases the safety and reliability of the operation of the electric network, and failure analysis engineering. In this way, theories that combine phasor measurements with the circuital laws of a PS, it has been developed, thus determining the stress level of specific areas. In this research, a methodology is developed for failure analysis and dispatch optimization, based on a grouping technique called k-means, which divides a PS into different control areas, it increases the level of stress between their areas, as a consequence, it could be determined, applying the concept of cut’s angle. With the above, critical areas are identified, and it avoids contingencies stages.

[1]  Jiakun Fang,et al.  Convolutional neural network-based power system transient stability assessment and instability mode prediction , 2020, Applied Energy.

[2]  Ricardo Manuel Arias Velásquez,et al.  Root cause analysis methodology for circuit breaker associated to GIS , 2020 .

[3]  Amangaldi Koochaki,et al.  An intelligent method for online voltage stability margin assessment using optimized ANFIS and associated rules technique. , 2020, ISA transactions.

[4]  Andrés Melgar,et al.  Reliability model for switchgear failure analysis applied to ageing , 2019, Engineering Failure Analysis.

[5]  Yanli Liu,et al.  Super Resolution Perception for Improving Data Completeness in Smart Grid State Estimation , 2020 .

[6]  Ramesh C. Bansal,et al.  AC microgrid protection – A review: Current and future prospective , 2020 .

[7]  Piergiorgio Alotto,et al.  Modelling of road-embedded transmitting coils for wireless power transfer , 2020, Comput. Electr. Eng..

[8]  Yuanyuan Wang,et al.  Developing graphical detection techniques for maintaining state estimation integrity against false data injection attack in integrated electric cyber-physical system , 2020, J. Syst. Archit..

[9]  Ricardo Manuel Arias Velásquez,et al.  Harmonic failure in the filter of Static Var Compensator , 2020 .

[10]  Ricardo Manuel Arias Velásquez,et al.  Bushing failure in power transformers and the influence of moisture with the spectroscopy test , 2018 .

[11]  Jennifer Vanessa Mejía Lara,et al.  The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators , 2018 .

[12]  Nikos Giatrakos,et al.  Omnibus outlier detection in sensor networks using windowed locality sensitive hashing , 2020, Future Gener. Comput. Syst..

[13]  P.H.A. Barra,et al.  A survey on adaptive protection of microgrids and distribution systems with distributed generators , 2020 .

[14]  M. Geethanjali,et al.  Fault localization for transmission lines with optimal Phasor Measurement Units , 2018, Comput. Electr. Eng..

[15]  R. A. Arias Velásquez,et al.  Insulation failure caused by special pollution around industrial environments , 2019, Engineering Failure Analysis.

[16]  Yilu Liu,et al.  Utilization of optical sensors for phasor measurement units , 2018 .

[17]  Frederick T. Sheldon,et al.  Detecting stealthy false data injection attacks in the smart grid using ensemble-based machine learning , 2020, Comput. Secur..

[18]  D. John Morrow,et al.  Technique for Pre-Compliance Testing of Phasor Measurement Units , 2018 .

[20]  Qingshan Xu,et al.  A robust GPS-based control scheme for power sharing and quality improvement in microgrid , 2020 .

[21]  Faraz Zafar Khan,et al.  Line Outage Detection Using Phasor Measurement Units , 2015 .

[22]  Ricardo Manuel Arias Velásquez,et al.  Model for failure analysis for overhead lines with distributed parameters associated to atmospheric discharges , 2019, Engineering Failure Analysis.

[23]  Jennifer Vanessa Mejía Lara,et al.  Corrosive Sulphur effect in power and distribution transformers failures and treatments , 2018 .

[24]  Shouxiang Wang,et al.  A novel smart meter data compression method via stacked convolutional sparse auto-encoder , 2020, International Journal of Electrical Power & Energy Systems.

[25]  D. Prasanna Vadana,et al.  Soft Phasor Measurement Unit , 2015 .

[26]  Abdelouahid Derhab,et al.  Survey of false data injection in smart power grid: Attacks, countermeasures and challenges , 2020, J. Inf. Secur. Appl..

[27]  Ricardo Manuel Arias Velásquez,et al.  New methodology for design and failure analysis of underground transmission lines , 2020 .

[28]  Ricardo Manuel Arias Velásquez,et al.  Failures in overhead lines grounding system and a new improve in the IEEE and national standards , 2019, Engineering Failure Analysis.

[29]  Jay Johnson,et al.  Distributed renewable energy resource trust metrics and secure routing , 2020, Comput. Secur..

[30]  Ricardo Manuel Arias Velásquez,et al.  Current transformer failure caused by electric field associated to circuit breaker and pollution in 500 kV substations , 2018 .

[31]  Qiuwei Wu,et al.  Analytically derived fixed termination time for stepwise inertial control of wind turbines—Part II: Application strategy , 2020 .

[32]  Ricardo Manuel Arias Velásquez,et al.  Reliability, availability and maintainability study for failure analysis in series capacitor bank , 2018 .

[33]  Gang Xie,et al.  Detecting false data attacks using machine learning techniques in smart grid: A survey , 2020, J. Netw. Comput. Appl..

[34]  Jennifer Vanessa Mejía Lara,et al.  Circuit breakers 500 kV degradation in substation reactors caused by inductive current , 2018 .