THE PHOTOPHYSICAL CONSTANTS OF SEVERAL FLUORESCENT DYES PERTAINING TO ULTRASENSITIVE FLUORESCENCE SPECTROSCOPY

Abstract— The successful implementation of ultrasensitive fluorescence spectroscopy of biological and chemical species depends upon certain photophysical parameters associated with the fluorescent dye used in the investigation. These parameters include the fluorescence quantum efficiency, photodestruction quantum efficiency, absorption cross section and fluorescence lifetime. These photophysical constants were measured for several fluorescent dyes that are used for the tagging of biological species. Three different solvents, ethanol, water and a cationic surfactant used above its critical micelle concentration, were studied. The effective photon yield (ratio of the fluorescence quantum yield to the photodestruction quantum efficiency) for the dyes is nearly 100 times greater in ethanol than it is in water because of the superior photostabilities of these dyes in ethanol solvents. The implications of these parameters for the design of an ultrasensitive fluorescence experiment are discussed.

[1]  I. Rosenthal,et al.  Photochemical stability of rhodamine 6G in solution , 1978 .

[2]  M. Walport,et al.  Molecular calibration in flow cytometry with sub-attogram detection limit. , 1986, Journal of immunological methods.

[3]  N. Dovichi,et al.  High-sensitivity fluorescence detector fluorescein isothiocyanate derivatives of amino acids separated by capillary zone electrophoresis. , 1989, Journal of chromatography.

[4]  A. Fletcher,et al.  Fluorescence quantum yields of some rhodamine dyes , 1982 .

[5]  C Schwager,et al.  Automated DNA sequencing: ultrasensitive detection of fluorescent bands during electrophoresis. , 1987, Nucleic acids research.

[6]  R. Keller,et al.  Ultrasensitive laser-induced fluorescence detection in hydrodynamically focused flows , 1987 .

[7]  Erich P. Ippen,et al.  Rapid photobleaching of organic laser dyes in continuously operated devices , 1971 .

[8]  J H Jett,et al.  Laser-induced fluorescence of flowing samples as an approach to single-molecule detection in liquids. , 1984, Analytical chemistry.

[9]  I Hemmilä,et al.  Fluoroimmunoassay: present status and key problems. , 1979, Clinical chemistry.

[10]  R A Mathies,et al.  Single-molecule fluorescence detection: autocorrelation criterion and experimental realization with phycoerythrin. , 1989, Proceedings of the National Academy of Sciences of the United States of America.

[11]  A. Oseroff,et al.  Rapid-flow resonance Raman spectroscopy of photolabile molecules: rhodopsin and isorhodopsin. , 1976, Proceedings of the National Academy of Sciences of the United States of America.

[12]  J. Weber Study of the influence of triplet quencher on the photobleaching of rhodamine-6G , 1973 .

[13]  Lloyd M. Smith,et al.  Fluorescence detection in automated DNA sequence analysis , 1986, Nature.

[14]  T. Hirschfeld Optical microscopic observation of single small molecules. , 1976, Applied optics.

[15]  J. Jett,et al.  High-speed DNA sequencing: an approach based upon fluorescence detection of single molecules. , 1989, Journal of biomolecular structure & dynamics.

[16]  N. Dovichi,et al.  Subattomole amino acid analysis by capillary zone electrophoresis and laser-induced fluorescence. , 1988, Science.

[17]  A. P. D'Silva,et al.  Multidimensional, laser-based instrument for the characterization of environmental samples for polycyclic aromatic compounds , 1986 .

[18]  T. Hirschfeld,et al.  Quantum efficiency independence of the time integrated emission from a fluorescent molecule. , 1976, Applied optics.

[19]  R. Alfano,et al.  Effect of soap on the fluorescent lifetime and quantum yield of rhodamine 6G in water , 1973 .

[20]  J. Jorgenson,et al.  High sensitivity laser induced fluorescence detection in capillary zone electrophoresis , 1988 .

[21]  E Gratton,et al.  Phase fluorometric method for determination of standard lifetimes. , 1988, Analytical chemistry.

[22]  M. Novotny,et al.  Capillary electrophoresis of amino sugars with laser-induced fluorescence detection. , 1991, Analytical chemistry.

[23]  R A Mathies,et al.  Optimization of high-sensitivity fluorescence detection. , 1990, Analytical chemistry.

[24]  J H Jett,et al.  Rapid DNA sequencing based upon single molecule detection. , 1991, Genetic analysis, techniques and applications.

[25]  Steven A. Soper,et al.  Detection and identification of single molecules in solution , 1992 .

[26]  A. Sugimura,et al.  Deterioration of rhodamine 6G dye solution in methanol , 1974 .

[27]  N. Dovichi,et al.  Interaction of capillary zone electrophoresis with a sheath flow cuvette detector , 1990 .

[28]  L. Stryer,et al.  Photostability studies of phycobiliprotein fluorescent labels. , 1987, Analytical biochemistry.

[29]  R. Zare,et al.  Determination of methotrexate and its major metabolite, 7-hydroxymethotrexate, using capillary zone electrophoresis and laser-induced fluorescence detection. , 1988, Journal of chromatography.

[30]  L. Middendorf,et al.  Continuous, on-line DNA sequencing using oligodeoxynucleotide primers with multiple fluorophores. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[31]  Steven A. Soper,et al.  Detection of single fluorescent molecules , 1990 .

[32]  M. Yamashita,et al.  Photodegradation mechanisms in laser dyes: A laser irradiated ESR study , 1976 .

[33]  James H. Jett,et al.  SINGLE-MOLECULE DETECTION OF RHODAMINE 6G IN ETHANOLIC SOLUTIONS USING CONTINUOUS WAVE LASER EXCITATION , 1991 .

[34]  J. Michael Ramsey,et al.  Single-molecule detection limits in levitated microdroplets , 1991 .

[35]  I Hemmilä,et al.  Fluoroimmunoassays and immunofluorometric assays. , 1985, Clinical chemistry.

[36]  J. M. Prober,et al.  A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. , 1987, Science.

[37]  H. Swerdlow,et al.  Three DNA sequencing methods using capillary gel electrophoresis and laser-induced fluorescence. , 1991, Analytical chemistry.

[38]  J B Shear,et al.  Fluorescence detection in capillary zone electrophoresis using a charge-coupled device with time-delayed integration. , 1991, Analytical chemistry.