Combining autocorrelation signals with delay multiply and sum beamforming algorithm for ultrasound imaging

Beamformer is one of the most important components in ultrasound imaging system. The delay and sum (DAS) beamforming algorithm has been widely used in recent decades due to its simplicity and robustness. However, it has poor impact on resolution and contrast. A new beamformer named filtered delay multiply and sum (F-DMAS) which was an alternative of delay multiply and sum (DMAS) was proposed to overcome these shortcomings of DAS. Although F-DMAS partially enhances the image quality, its performance still has room for improvement. Therefore, a novel beamformer named lag-based delay multiply and sum (L-DMAS) which combines autocorrelation signals with DMAS algorithm is proposed by us to improve its efficiency. Field II was employed to synthesize a point target phantom and a cyst phantom to compare the performance between DAS, F-DMAS, double stage delay multiply and sum (DS-DMAS), and L-DMAS. We also estimate the performance of four algorithms on experimental data and in vivo data. These results show that both DS-DMAS and L-DMAS are better than DAS and F-DMAS in each case. In some cases, DS-DMAS and L-DMAS have little difference in performance, but in other cases, L-DMAS outperforms DS-DMAS. Graphical Abstract Graphical Abstract

[1]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[2]  Liang Song,et al.  Delay-multiply-and-sum-based synthetic aperture focusing in photoacoustic microscopy , 2016, Journal of biomedical optics.

[3]  Dongwoon Hyun,et al.  Lesion Detectability in Diagnostic Ultrasound with Short-Lag Spatial Coherence Imaging , 2011, Ultrasonic imaging.

[4]  Ali Mahloojifar,et al.  Linear-array photoacoustic imaging using minimum variance-based delay multiply and sum adaptive beamforming algorithm , 2018, Journal of biomedical optics.

[5]  Ole Marius Hoel Rindal,et al.  Influence of the delay-multiply-and-sum beamformer on the ultrasound image amplitude , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[6]  Ole Marius Hoel Rindal,et al.  Signal Coherence and Image Amplitude With the Filtered Delay Multiply and Sum Beamformer , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[8]  Shi Zhang,et al.  An efficient subarray average delay multiply and sum beamformer algorithm in ultrasound imaging , 2018, Ultrasonics.

[9]  Dongwoon Hyun,et al.  Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging. , 2018, Ultrasound in medicine & biology.

[10]  Alessandro Ramalli,et al.  Spatial Coherence of Backscattered Signals in Multi-Line Transmit Ultrasound Imaging and Its Effect on Short-Lag Filtered-Delay Multiply and Sum Beamforming , 2018 .

[11]  Giovanni Magenes,et al.  The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging , 2015, IEEE Transactions on Medical Imaging.

[12]  Gregg Trahey,et al.  In Vivo Application of Short-Lag Spatial Coherence and Harmonic Spatial Coherence Imaging in Fetal Ultrasound , 2015, Ultrasonic imaging.

[13]  Muyinatu A. Lediju Bell,et al.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  Steven W. Smith,et al.  The Scientist and Engineer's Guide to Digital Signal Processing , 1997 .

[15]  B.D. Van Veen,et al.  Beamforming: a versatile approach to spatial filtering , 1988, IEEE ASSP Magazine.

[16]  Piero Tortoli,et al.  High Frame-Rate, High Resolution Ultrasound Imaging With Multi-Line Transmission and Filtered-Delay Multiply And Sum Beamforming , 2017, IEEE Trans. Medical Imaging.

[17]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[18]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  J-F Synnevåg,et al.  A low-complexity data-dependent beamformer , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  R. Waag,et al.  About the application of the van Cittert-Zernike theorem in ultrasonic imaging , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Dongwoon Hyun,et al.  Beamforming and Speckle Reduction Using Neural Networks , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[23]  Francois Vignon,et al.  Capon beamforming in medical ultrasound imaging with focused beams , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging , 2018, IEEE Transactions on Biomedical Engineering.

[25]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[26]  Ali Mahloojifar,et al.  Medical photoacoustic beamforming using minimum variance-based delay multiply and sum , 2017, Other Conferences.

[27]  Emad M Boctor,et al.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds. , 2013, Biomedical optics express.

[28]  W.F. Walker,et al.  A constrained adaptive beamformer for medical ultrasound: initial results , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[29]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[30]  Nguyen Duc Thang,et al.  Confocal Microwave Imaging for Breast Cancer Detection: Delay-Multiply-and-Sum Image Reconstruction Algorithm , 2008, IEEE Transactions on Biomedical Engineering.

[31]  Muyinatu A. Lediju Bell,et al.  Robust Short-Lag Spatial Coherence Imaging , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.