Non-invasive monitoring of blood pressure using the Philips Intellivue MP50 monitor cannot replace invasive blood pressure techniques in surgery patients under general anesthesia

The Philips Intellivue MP50 monitor provides a method for non-invasive, near-continuous blood pressure (BP) monitoring and is designed to be an alternative to direct intra-arterial BP (IABP) measurement. However, no studies have specifically compared non-invasive and invasive BP measurements using the monitor. The present retrospective study observed 515 patients undergoing surgery with general anesthesia, whose invasive (intra-radial, femoral or dorsalis pedis artery) and non-invasive (oscillometric) BP (NIBP) were monitored simultaneously using the monitor. These data were analyzed using correlations, regressions and Bland-Altman plots. The patients were placed in a supine position during surgery. The correlation data for invasive BP and NIBP measurements were: for intra-radial measurements, r2=0.51 (bias and precision, 11.04±15.22 and 14.76±11.64 mmHg, respectively) for systolic BP (SBP) and r2=0.27 (6.17±11.95 and 9.77±9.25 mmHg, respectively) for diastolic BP (DBP); for intra-femoral measurements: r2=0.57 (14.79±14.55 and 17.15±11.68 mmHg, respectively) for SBP and r2=0.45 (4.12±9.70 and 7.49±7.40 mmHg, respectively) for DBP; and for intra-dorsalis pedis measurements: r2=0.33 (13.00±16.81 and 17.34±12.28 mmHg, respectively) for SBP and r2=0.30 (0.17±11.27 and 8.44±7.46 mmHg, respectively) for DBP. According to this data, the NIBP measured by the Philips Intellivue MP50 monitor showed low positive correlations and poor agreement with the IABP, as calculated by Bland-Altman analysis. Therefore, the use of oscillometric BP measured by the monitor in surgery patients under general anesthesia is not generally recommended.

[1]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[2]  J. Kermode,et al.  Comparison of the Finapres Blood Pressure Monitor with Intra-arterial Manometry during Induction of Anaesthesia , 1989, Anaesthesia and intensive care.

[3]  L. Bigatello,et al.  Hemodynamic monitoring. , 2002, Minerva anestesiologica.

[4]  E. Frezza,et al.  Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. , 1998, The American surgeon.

[5]  Bruce Neal,et al.  1999 World Health Organization-International Society of Hypertension Guidelines for the Management of Hypertension. Guidelines Subcommittee. , 1999, Journal of hypertension.

[6]  J. Bander,et al.  Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive? , 2006, Critical care.

[7]  Jeff A. Clark,et al.  Discrepancies between direct and indirect blood pressure measurements using various recommendations for arm cuff selection. , 2002, Pediatrics.

[8]  T. Neff,et al.  Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients , 2009, BMC anesthesiology.

[9]  X. Capdevila,et al.  Noninvasive monitoring of blood pressure in the critically ill: Reliability according to the cuff site (arm, thigh, or ankle) , 2012, Critical care medicine.

[10]  T. A. Bowdle,et al.  Complications of invasive monitoring. , 2002, Anesthesiology clinics of North America.

[11]  Azriel Perel,et al.  Clinical review: Complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine , 2002, Critical care.

[12]  J F Potter,et al.  Extract from : , 2009 .

[13]  K. Belani,et al.  Accuracy of radial artery blood pressure determination with the Vasotrac™ , 1999, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[14]  R G Wilkins,et al.  Radial artery cannulation and ishaemic damage: a review , 1985, Anaesthesia.

[15]  T Ishikawa,et al.  Blood Pressure Measurement by Arterial Tonometry in Controlled Hypotension , 1991, Anesthesia and analgesia.

[16]  Harald Herkner,et al.  Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients , 2003, Critical care medicine.

[17]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[18]  Bruner Jm,et al.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III. , 1981 .

[19]  K. Kang,et al.  Study for the discrepancy of arterial blood pressure in accordance with method, age, body part of measurement during general anesthesia using sevoflurane , 2011, Korean journal of anesthesiology.

[20]  J. Brock‐Utne,et al.  A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor , 2009, Journal of Clinical Monitoring and Computing.

[21]  M Poliac,et al.  A new noninvasive method to measure blood pressure: results of a multicenter trial. , 1999, Anesthesiology.

[22]  Measurement of mean arterial pressure: comparison of the Vasotrac monitor with the finger differential oscillometric device. , 2010, Physiological research.

[23]  R. Reneman,et al.  Contours of pressure and flow waves in arteries , 2011 .

[24]  David Hill,et al.  A Comparison of Radial Artery Blood Pressure Determination Between the Vasotrac Device and Invasive Arterial Blood Pressure Monitoring in Adolescents Undergoing Scoliosis Surgery , 2005, Anesthesia and analgesia.

[25]  J. Derr,et al.  The accuracy of Finapres noninvasive mean arterial pressure measurements in anesthetized patients. , 1991, Anesthesiology.

[26]  D. Zurakowski,et al.  A Comparison of the Vasotrac with Invasive Arterial Blood Pressure Monitoring in Children After Pediatric Cardiac Surgery , 2005, Anesthesia and analgesia.

[27]  N. Gravenstein,et al.  An Accuracy Evaluation of the T-Line® Tensymeter (Continuous Noninvasive Blood Pressure Management Device) versus Conventional Invasive Radial Artery Monitoring in Surgical Patients , 2006, Anesthesia and analgesia.

[28]  J. Bruner,et al.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III. , 1981, Medical instrumentation.

[29]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[30]  R. Reneman General principles for measuring arterial waves , 2011 .