An Early Investigation into Possible Alternatives to Stapled Hysterotomy in Open Fetal Surgery

Abstract Purpose We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery. Study Design Initial studies compared the LigaSure Impact and Harmonic ACE + 7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term = 145; n = 7) underwent hysterotomy using either device. Hysterotomy edges were resected, and thermal injury extent was determined by histopathological assessment. Upon determining a superior device, subsequent studies compared this to the AutoSuture Premium Poly CS*-57 Stapler in uterine healing. Pregnant ewes (n = 6) at an EGA of 87 to 93 days underwent 6-cm hysterotomy in each gravid horn with either the stapler (n = 5) or Harmonic (n = 5) followed by closure and animal recovery. After 37 to 42 days, uterine healing was assessed by evaluating tensile strength and histopathology. Results Thermal damage was more extensive with the LigaSure (n = 11 hysterotomies) than with the Harmonic (n = 11; 5.6 ± 1 vs. 3.1 ± 0.6 mm; p < 0.0001);therefore, the Harmonic was selected for healing studies. Gross scar appearance and tensile strength were the same between the Harmonic and stapler. The stapler caused more fibrosis (4/7 samples with “moderate” fibrosis vs. 0/8 with the Harmonic; p = 0.02). Conclusion The Harmonic ACE + 7 caused less thermal injury than the LigaSure Impact and performed similar to the CS*-57 Stapler in uterine healing with continued gestation.

[1]  D. Farmer,et al.  Lessons from the Barn to the Operating Suite: A Comprehensive Review of Animal Models for Fetal Surgery. , 2018, Annual review of animal biosciences.

[2]  D. Farmer,et al.  Fetal Surgery for Myelomeningocele: A Systematic Review and Meta-Analysis of Outcomes in Fetoscopic versus Open Repair , 2017, Fetal Diagnosis and Therapy.

[3]  E. Romano,et al.  Fetal Myelomeningocele Repair through a Mini-Hysterotomy , 2016, Fetal Diagnosis and Therapy.

[4]  A. Kent,et al.  Clinical utility of a novel ultrasonic vessel sealing device in transecting and sealing large vessels during laparoscopic hysterectomy using advanced hemostasis mode. , 2016, European journal of obstetrics, gynecology, and reproductive biology.

[5]  F. Lim,et al.  Management of fetal teratomas , 2016, Pediatric Surgery International.

[6]  Nisar Zaidi,et al.  The Covidien LigaSure Maryland Jaw Device , 2015, Expert review of medical devices.

[7]  S. Carr,et al.  Fetal surgery: principles, indications, and evidence. , 2014, Obstetrics and gynecology.

[8]  P. Buettner,et al.  Harmonic scalpel compared with conventional excisional haemorrhoidectomy: a meta-analysis of randomized controlled trials , 2014, Techniques in Coloproctology.

[9]  S. Haeri,et al.  Maternal morbidity and reproductive outcomes related to fetal surgery. , 2013, Journal of pediatric surgery.

[10]  Z. Pogorelić,et al.  Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure. , 2012, Canadian journal of surgery. Journal canadien de chirurgie.

[11]  A. Jangjoo,et al.  Laparoscopic Splenectomy: Ligasure or Clip Ligation? , 2012, Surgical laparoscopy, endoscopy & percutaneous techniques.

[12]  A. Carvalho,et al.  Hemostasis in thyroid surgery: Harmonic scalpel versus other techniques—a meta-analysis , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[13]  M. Harrison,et al.  A history of fetal surgery. , 2009, Clinics in perinatology.

[14]  Alberto Arezzo,et al.  Electrothermal Bipolar Vessel Sealing System vs. Harmonic Scalpel in Colorectal Laparoscopic Surgery: A Prospective, Randomized Study , 2009, Diseases of the colon and rectum.

[15]  Franklin Dexter,et al.  Operative Time and Other Outcomes of the Electrothermal Bipolar Vessel Sealing System (LigaSure™) Versus Other Methods for Surgical Hemostasis: A Meta-Analysis , 2008, Surgical innovation.

[16]  F. Romano,et al.  Ligasure versus Ultracision® in thyroid surgery: a prospective randomized study , 2008, Langenbeck's Archives of Surgery.

[17]  Yingbin Xu,et al.  Experimental study on repairing of nude mice skin defects with composite skin consisting of xenogeneic dermis and epidermal stem cells and hair follicle dermal papilla cells. , 2008, Burns : journal of the International Society for Burn Injuries.

[18]  B. Mercer,et al.  Myometrial thickness according to uterine site, gestational age and prior cesarean delivery , 2004, The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians.

[19]  R. Anthony,et al.  The pregnant sheep as a model for human pregnancy. , 2008, Theriogenology.

[20]  R. Ball,et al.  Maternal morbidity after maternal-fetal surgery. , 2006, American journal of obstetrics and gynecology.

[21]  Apostolos Papalois,et al.  Comparison of Monopolar Electrocoagulation, Bipolar Electrocoagulation, Ultracision, and Ligasure , 2006, Surgery Today.

[22]  E. Targarona,et al.  Energy Sources for Laparoscopic Colectomy: A Prospective Randomized Comparison of Conventional Electrosurgery, Bipolar Computer-Controlled Electrosurgery and Ultrasonic Dissection. Operative Outcome and Costs Analysis , 2005, Surgical innovation.

[23]  T. Crombleholme,et al.  Reproductive outcomes after pregnancy complicated by maternal-fetal surgery. , 2004, American journal of obstetrics and gynecology.

[24]  M. King,et al.  Chorioamniotic Membrane Separation following Open Fetal Surgery: Pregnancy Outcome , 2003, Fetal Diagnosis and Therapy.

[25]  Abe Fingerhut,et al.  Harmonic scalpel™ in laparoscopic colorectal surgery , 2001, Diseases of the colon and rectum.

[26]  M. Enkin,et al.  Absorbable staples for uterine incision at caesarean section. , 2000, The Cochrane database of systematic reviews.

[27]  L. Reinisch,et al.  Comparisons of wound healing among excisional, laser‐created, and standard thermal burns in porcine wounds of equal depth , 1997, Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society.

[28]  C. Qualls,et al.  Comparison of Absorbable Uterine Staples and Traditional Hysterotomy During Cesarean Delivery , 1996, Obstetrics and gynecology.

[29]  M. Longaker,et al.  Maternal Outcome after Open Fetal Surgery: A Review of the First 17 Human Cases , 1991, JAMA.

[30]  A. Flake,et al.  Cesarean Delivery and Hysterotomy Using an Absorbable Stapling Device , 1989, Obstetrics and gynecology.

[31]  A. Flake,et al.  Surgical Techniques, Equipment and InstrumentsFetal Surgery in the Primate III. Maternal Outcome After Fetal Surgery , 1986 .

[32]  J. V. von Fraunhofer,et al.  Effects of thermal knives on wound healing. , 1985, Obstetrics and gynecology.