Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging
暂无分享,去创建一个
Takuya Hayashi | Seiichi Yamamoto | H. Watabe | H. Iida | T. Zeniya | T. Aoi | K. Min Kim | N. Teramoto | T. Takeno | Y. Ohta | H. Mashino | Toshihiro Ota | S. Yamamoto
[1] H. Anger,et al. CHAPTER 19 – RADIOISOTOPE CAMERAS , 1967 .
[2] H. Atkins,et al. Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[3] R. Jaszczak,et al. Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. , 1994, Physics in medicine and biology.
[4] Y. Yonekura,et al. Ultra-high resolution SPECT system using four pinhole collimators for small animal studies. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[5] R. Jaszczak,et al. The effect of gamma ray penetration on angle-dependent sensitivity for pinhole collimation in nuclear medicine. , 1997, Medical physics.
[6] H. Iida,et al. Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT , 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[7] A. P. Jeavons,et al. A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998 .
[8] Koichi Ogawa,et al. Ultra high resolution pinhole SPECT for small animal study , 1998 .
[9] A. Jeavons,et al. A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).
[10] Horst Halling,et al. Compact high resolution detector for small animal SPECT , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).
[11] Ronald J. Jaszczak,et al. Analytic determination of pinhole collimator sensitivity with penetration , 2001, IEEE Transactions on Medical Imaging.
[12] S R Meikle,et al. Instrumentation and methodology for quantitative pre-clinical imaging studies. , 2001, Current pharmaceutical design.
[13] T. Hirai,et al. Serial evaluation of fatty acid metabolism in rats with myocardial infarction by pinhole SPECT , 2001, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[14] Jurgen Seidel,et al. Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability , 2001 .
[15] A. Chatziioannou. PET scanners dedicated to molecular imaging of small animal models. , 2002, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.
[16] E. Hoffman,et al. Performance evaluation of A-SPECT: a high resolution desktop pinhole SPECT system for imaging small animals , 2002 .
[17] P. Acton,et al. Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography , 2002, European Journal of Nuclear Medicine and Molecular Imaging.
[18] Donald W. Wilson,et al. Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[19] H. Iida,et al. Absolute quantitation of regional myocardial blood flow of rats using dynamic pinhole SPECT , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.
[20] Christian Kolbitsch,et al. Evaluation of Striatal Dopamine Transporter Function in Rats by in Vivo β-[123I]CIT Pinhole SPECT , 2002, NeuroImage.
[21] N. Schramm,et al. High-resolution SPECT using multi-pinhole collimation , 2002, IEEE Nuclear Science Symposium Conference Record.
[22] S. Cherry,et al. MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. , 2003, Physics in medicine and biology.
[23] Dedicated small field of view SPECT system based on a 5" PSPMT and crystal scintillator array for high resolution small animal cardiac imaging , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).
[24] M. Defrise,et al. Correction for imperfect camera motion and resolution recovery in pinhole SPECT , 2004, IEEE Symposium Conference Record Nuclear Science 2004..
[25] H. Iida,et al. Optimization of the width of the photopeak energy window in the TDCS technique for scatter correction in quantitative SPECT , 2004, IEEE Transactions on Nuclear Science.
[26] Hiroyuki Kudo,et al. A new reconstruction strategy for image improvement in pinhole SPECT , 2004, European Journal of Nuclear Medicine and Molecular Imaging.
[27] P. V. van Rijk,et al. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.