Comparison of In Vitro Velocity Measurements in a Scaled Total Cavopulmonary Connection with Computational Predictions

AbstractMinimizing pressure drop through the total cavopulmonary surgical connection (TCPC), where the superior and inferior vena cavae (SVC), (IVC) are connected directly to the right and left pulmonary arteries, is an important clinical consideration. Computational fluid dynamics (CFD) models have been used to examine the impact of connection configuration on TCPC pressure drop. However, few studies have validated CFD results with experimental data. This study compares flow field measurements on two different TCPC models at varying SVC:IVC flow rate ratios using CFD and digital particle image velocimetry (DPIV). Although the primary flow fields generated by CFD and DPIV methods were similar for the majority of flow conditions, three key differences were found: (1) the CFD model did not reproduce the 3D complexity of flow interactions in the no-offset model with 50:50 flow ratio; (2)in vitro results showed consistently higher secondary flow components within the pulmonary artery segments, especially for the no-offset model; (3) recirculation areas for the 1/2 diameter offset model were consistently higher forin vitro versus CFD results. We conclude that this numerical model is a reasonable means of studying TCPC flow, although modifications need to be addressed to ensure that numerical results reproduce secondary flow characteristics. © 2003 Biomedical Engineering Society. PAC2003: 8719Uv, 8719Hh, 8710+e

[1]  D. Liepsch,et al.  Measurement and calculations of laminar flow in a ninety degree bifurcation. , 1982, Journal of biomechanics.

[2]  P. D. del Nido,et al.  Fluid dynamic comparison of intra-atrial and extracardiac total cavopulmonary connections. , 1999, The Journal of thoracic and cardiovascular surgery.

[3]  R. Shandas,et al.  Accuracy of the Bernoulli Equation for Estimation of Pressure Gradient Across Stenotic Blalock–Taussig Shunts: An In Vitro and Numerical Study , 2000, Pediatric Cardiology.

[4]  L. Lourenço Particle Image Velocimetry , 1989 .

[5]  F. Migliavacca,et al.  Computational fluid dynamics in paediatric cardiac surgery , 2000, Images in paediatric cardiology.

[6]  R Pietrabissa,et al.  Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavo-pulmonary connections. , 1996, The Journal of thoracic and cardiovascular surgery.

[7]  M. Leval,et al.  The Fontan Circulation: What Have We Learned? What to Expect? , 1998, Pediatric Cardiology.

[8]  Thomas J. R. Hughes,et al.  Finite element modeling of blood flow in arteries , 1998 .

[9]  D J Sahn,et al.  Evaluating isovelocity surface area flow convergence method with finite element modeling. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[10]  C. Lorenz,et al.  Alterations in pulmonary artery flow patterns and shear stress determined with three-dimensional phase-contrast magnetic resonance imaging in Fontan patients. , 1998, The Journal of thoracic and cardiovascular surgery.

[11]  H. Q. Yang,et al.  An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound. , 1994, The Journal of heart valve disease.

[12]  Robin Shandas,et al.  Influence of connection geometry and SVC-IVC flow rate ratio on flow structures within the total cavopulmonary connection: a numerical study. , 2002, Journal of biomechanical engineering.

[13]  P. Kilner,et al.  Total cavopulmonary connection: a logical alternative to atriopulmonary connection for complex Fontan operations. Experimental studies and early clinical experience. , 1988, The Journal of thoracic and cardiovascular surgery.

[14]  P. D. del Nido,et al.  Bidirectional superior cavopulmonary anastomosis improves mechanical efficiency in dilated atriopulmonary connections. , 1999, The Journal of thoracic and cardiovascular surgery.

[15]  Hwang Nh,et al.  Numerical study of squeeze-flow in tilting disc mechanical heart valves. , 1996 .

[16]  Ajit P. Yoganathan,et al.  Importance of Accurate Geometry in the Study of the Total Cavopulmonary Connection: Computational Simulations and In Vitro Experiments , 2001, Annals of Biomedical Engineering.

[17]  H. Sievers,et al.  Superior hydrodynamics of a modified cavopulmonary connection for the Norwood operation. , 1998, The Annals of thoracic surgery.

[18]  R Fumero,et al.  A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection. , 1996, Journal of biomechanics.

[19]  R. Shandas,et al.  Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations: a numerical study. , 1998, Circulation.

[20]  M. Crochet,et al.  Comparison by computerized numeric modeling of energy losses in different Fontan connections. , 1995, Circulation.

[21]  J. M. Siegel,et al.  Computational simulation of magnetic resonance angiograms in stenotic vessels: Effect of stenosis severity , 1996 .

[22]  René M. Botnar,et al.  Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements. , 2000, Journal of biomechanics.

[23]  H. Low,et al.  Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defects. , 1993, Journal of biomedical engineering.

[24]  S E Maier,et al.  In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging. , 1998, Circulation.

[25]  A. Yoganathan,et al.  In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricle. , 1996, Journal of the American College of Cardiology.

[26]  F. Migliavacca,et al.  A computational pulsatile model of the bidirectional cavopulmonary anastomosis: the influence of pulmonary forward flow. , 1996, Journal of biomechanical engineering.

[27]  George P. Chatzimavroudis,et al.  Fluid Mechanic Assessment of the Total Cavopulmonary Connection using Magnetic Resonance Phase Velocity Mapping and Digital Particle Image Velocimetry , 2004, Annals of Biomedical Engineering.

[28]  R Shandas,et al.  Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: in vitro steady. , 1996, Biomedical sciences instrumentation.

[29]  R. Shandas,et al.  Utility of the proximal jet width in the assessment of regurgitant and stenotic orifices--effect of low velocity filter and comparison to actual vena contracta width: an in vitro and numerical study. , 2000, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[30]  V. Makhijani,et al.  Application of computational fluid dynamics techniques to blood pumps. , 1996, Artificial organs.

[31]  Ramakrishnan Sukuma,et al.  Application of Computational Fluid Dynamics Techniques to Blood Pumps. , 1996, Artificial organs.

[32]  M. D. de Leval The Fontan Circulation: What Have We Learned? What to Expect? , 1998, Pediatric cardiology.

[33]  F. Fontan,et al.  Surgical repair of tricuspid atresia , 1971, Thorax.

[34]  P. Walker,et al.  Hemodynamics of the Fontan connection: an in-vitro study. , 1995, Journal of biomechanical engineering.

[35]  A. Yoganathan,et al.  Noninvasive fluid dynamic power loss assessments for total cavopulmonary connections using the viscous dissipation function: a feasibility study. , 2001, Journal of biomechanical engineering.

[36]  P J Dionne,et al.  Three‐Dimensional Coupled Fluid‐Structure Simulation of Pericardial Bioprosthetic Aortic Valve Function , 1997, ASAIO journal.

[37]  M. Fogel,et al.  The nature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the Fontan operation. , 1997, The Journal of thoracic and cardiovascular surgery.