Percutaneous Cement-Augmented Screws Fixation in the Fractures of the Aging Spine: Is It the Solution?

Introduction. Management of elderly patients with thoracolumbar fractures is still challenging due to frequent osteoporosis and risk of screws pull-out. The aim of this study was to evaluate results of a percutaneous-only procedure to treat these fragile patients using cement-augmented screws. Methods. 12 patients diagnosed with a thoracolumbar fracture associated with an important loss of bone stock were included in this prospective study. Surgical procedure included systematically a percutaneous osteosynthesis using cemented fenestrated screws. When necessary, additional anterior support was performed using a kyphoplasty procedure. Clinical and radiographic evaluations were performed using CT scan. Results. On the whole series, 15 fractures were diagnosed and 96 cemented screws were inserted. The difference between the pre- and postoperative vertebral kyphosis was statistically significant (12.9° versus 4.4°, P = 0.0006). No extrapedicular screw was reported and one patient was diagnosed with a cement-related pulmonary embolism. During follow-up period, no infectious complications, implant failures, or pull-out screws were noticed. Discussion. Aging spine is becoming an increasing public health issue. Management of these patients requires specific attention due to the augmented risk of complications. Using percutaneous-only screws fixation with cemented screw provides satisfactory results. A rigorous technique is mandatory in order to achieve best outcomes.

[1]  H. Steiner,et al.  Cement Embolism into the Venous System after Pedicle Screw Fixation: Case Report, Literature Review, and Prevention Tips , 2013, Orthopedic reviews.

[2]  R. Meffert,et al.  Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial , 2013, European Spine Journal.

[3]  F. Pfeiffer,et al.  Pedicle Screw Design and Cement Augmentation in Osteoporotic Vertebrae: Effects of Fenestrations and Cement Viscosity on Fixation and Extraction , 2012, Spine.

[4]  C. Court,et al.  Percutaneous fixation of thoracolumbar fractures: current concepts. , 2012, Orthopaedics & traumatology, surgery & research : OTSR.

[5]  H. Goost,et al.  Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement , 2012, Biomedizinische Technik. Biomedical engineering.

[6]  G. Appelboom,et al.  Minimally Invasive Spinal Arthrodesis in Osteoporotic Population Using a Cannulated and Fenestrated Augmented Screw: Technical Description and Clinical Experience , 2012, Minimally invasive surgery.

[7]  N. Endo,et al.  Polymethylmethacrylate Augmentation of Pedicle Screws Increases the Initial Fixation in Osteoporotic Spine Patients , 2012, Journal of spinal disorders & techniques.

[8]  Yang Zhang,et al.  Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients. , 2012, The Journal of surgical research.

[9]  S. Boriani,et al.  Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases , 2011, Journal of Orthopaedics and Traumatology.

[10]  L. Álvarez,et al.  Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentation , 2011, European Spine Journal.

[11]  Serkan Erkan,et al.  Biomechanical Evaluation of a Novel Fenestrated Pedicle Screw Augmented With Bone Cement in Osteoporotic Spines , 2011, Spine.

[12]  Chien-Lin Liu,et al.  Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body , 2011, European Spine Journal.

[13]  Zi-xiang Wu,et al.  Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw , 2011, Archives of Orthopaedic and Trauma Surgery.

[14]  A Jay Khanna,et al.  Instrumentation of the osteoporotic spine: biomechanical and clinical considerations. , 2011, The spine journal : official journal of the North American Spine Society.

[15]  J. Gaudart,et al.  Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures , 2010, European Spine Journal.

[16]  Ho Yeol Zhang,et al.  Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine : a three-year follow-up of 37 patients. , 2009, Journal of Korean Neurosurgical Society.

[17]  Douglas L Burton,et al.  Cement Augmentation of Pedicle Screw Fixation Using Novel Cannulated Cement Insertion Device , 2009, Spine.

[18]  R. Vaidya,et al.  Biomechanical Analysis of Different Techniques in Revision Spinal Instrumentation: Larger Diameter Screws Versus Cement Augmentation , 2008, Spine.

[19]  R. McLain,et al.  Primary Pedicle Screw Augmentation in Osteoporotic Lumbar Vertebrae: Biomechanical Analysis of Pedicle Fixation Strength , 2007, Spine.

[20]  Wafa Skalli,et al.  Gravity Line Analysis in Adult Volunteers: Age-Related Correlation With Spinal Parameters, Pelvic Parameters, and Foot Position , 2006, Spine.

[21]  J. Chiras,et al.  Percutaneous vertebroplasty for spinal metastases: complications. , 2006, Radiology.

[22]  S. Cook,et al.  Biomechanical study of pedicle screw fixation in severely osteoporotic bone. , 2004, The spine journal : official journal of the North American Spine Society.

[23]  A. Evans,et al.  Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. , 2002, Journal of neurosurgery.