Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study

Abstract Background: The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS) titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces. Methods: In a porcine model (8 animals, 51±1 kg), arteries were prepared immediately after euthanisation, assigned to either a medium (2–4 mm; n=120) or a medium-large (3.5–7 mm; n=120) clip size group, and clipped with the appropriate clip size. After dissection, axial and radial pull-off forces were measured. Results: The axial pull-off force of the DS-Clip was higher than one single-shanked clip and comparable to the other single-shanked clip, and overall was linearly correlated to the cross-sectional area of the clip. The radial pull-off force of the DS-Clip was significantly higher than both single-shanked clips and, for the single-shanked clips, was correlated to the total clip thickness. The variation of radial pull-off force was lower for the DS-Clip due to a defined catch in the clip applier. Conclusions: The radial pull-off force was lower than the axial pull-off force in total and therefore appears to be the critical point of dislocation. Due to the higher total holding mass, the DS-Clip provided a clear advantage in this regard and might therefore decrease the dislocation rate. The catch in the applier increases the reproducibility in clip placement.

[1]  M. Wente,et al.  The TICAP-Study (titanium clips for appendicular stump closure): A prospective multicentre observational study on appendicular stump closure with an innovative titanium clip , 2015, BMC Surgery.

[2]  Jin‐Young Jang,et al.  Comparison of various methods of vessel ligation: what is the safest method? , 2013, Surgical Endoscopy.

[3]  Y. Saito,et al.  Thoracic empyema due to migrated endoclips after laparoscopic cholecystectomy , 2012, Asian journal of endoscopic surgery.

[4]  P. Kienle,et al.  Appendix stump closure with titanium clips in laparoscopic appendectomy , 2011, Langenbeck's Archives of Surgery.

[5]  A. Dennison,et al.  Bile duct "clip-stones"--why a stitch in time could save nine. , 2010, Hepato-gastroenterology.

[6]  M. Miyazato,et al.  Migration of a metal clip into the urinary bladder , 2009, Urological Research.

[7]  Seung-June Oh,et al.  Open conversion from laparoscopic nephrectomy: slippage of surgical clips ligating the renal artery affected by atherosclerosis. , 2004, The Journal of urology.

[8]  R. Heintjes,et al.  Renal artery clip dislodgement during hand-assisted laparoscopic living donor nephrectomy , 2003, Surgical Endoscopy And Other Interventional Techniques.

[9]  S. Schwaitzberg,et al.  A comparison of holding strength of various surgical clips , 2003, Surgical Endoscopy And Other Interventional Techniques.

[10]  S. Nawa,et al.  Choledochal stenosis and lithiasis caused by penetration and migration of surgical metal clips. , 2000, Journal of hepato-biliary-pancreatic surgery.

[11]  K. Sugimachi,et al.  Clip migration causes choledocholithiasis after laparoscopic cholecystectomy. , 2000, Surgical endoscopy.

[12]  B. Geissler,et al.  DIE MAMMAREKONSTRUKTION MIT DEM FREIEN MIKROVASKULAREN UNTERBAUCHLAPPEN : REKONSTRUKTIVES ACCESSOIRE ODER GOLDENER STANDARD , 1998 .

[13]  F. Lindemann,et al.  [Dislocation of clips of the cystic duct stump]. , 1998, Zentralblatt fur Chirurgie.

[14]  B. Geissler,et al.  Laparoskopisch applizierte Clips am humanen Ductus cysticus – Ein experimenteller Dislokationsvergleich zwischen resorbierbaren und Titan-Clips , 1997, Der Chirurg.

[15]  F. Lindemann,et al.  [Laparoscopically placed clips on the human cystic duct--an experimental comparison of dislocation between resorbable and titanium clips]. , 1997, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen.

[16]  W. Grundfest,et al.  Safety evaluation of laparoscopically applied clips. , 1996, Journal of laparoendoscopic surgery.

[17]  S. Mulvihill,et al.  How secure are laparoscopically placed clips? An in vitro and in vivo study. , 1992, Archives of surgery.