Impact of roof integrated PV orientation on the residential electricity peak demand

Peak electricity demand has been an issue in the Desert Southwest region of the US, due to extreme summer temperatures. To address this issue, a consortium was formed between the University of Nevada, Las Vegas, Pulte Homes, and NV Energy. An energy efficient residential community was developed by the team in Las Vegas with approximately 200 homes to study substation-level peak reduction strategies. A summer peak reduction of more than 65%, between 1:00PM and 7:00PM, compared to code standard housing developments is the targeted goal of the project. Approximately 50 homes are already built and some are occupied. The energy performances of the homes have been monitored and are presented in this paper. Several peak electric load reduction strategies such as energy efficiency in buildings, roof integrated photovoltaics (PV) and direct load control have been applied. Though all the homes in the developed community are installed with 1.8kWp PV systems, the orientation of the PV system depends on the building orientation. Focus of this paper is to find the impact of PV orientation on the peak load from a building. In addition, different time-of-use (TOU) energy pricing options are offered by the local electrical utility company. Hence it is important to find an optimal pricing option for each building. A computer model has been developed for one of the homes in the new development using building energy simulation code, ENERGY-10. Calculations on the PV orientations have shown that a south and 220° (i.e. 40° west of due south) orientations are economically optimal for homes enrolled to flat electricity pricing schedule and time of use pricing respectively. As predicted by the simulations, the energy efficiency methods in the home have decreased the total annual energy by 38% compared to a code standard home of the same size. Further, the energy efficiency methods in the building coupled with a 220° oriented PV and 1.1°C increase in thermostat temperature for three hours (from 3:00 to 6:00PM) reduced the peak energy demand by 62% compared to a code standard building of the same size. Battery storage is the other option that will be considered in the project at a later time which is expected to carry the project well beyond its peak reduction goals.

[1]  Stefano Paolo Corgnati,et al.  Thermal mass activation by hollow core slab coupled with night ventilation to reduce summer cooling loads , 2007 .

[2]  Robert F. Boehm,et al.  Economic Feasibility of Energy Efficiency Measures in Residential Buildings , 2011 .

[3]  G. C. Bakos,et al.  Technoeconomic assessment of a building-integrated PV system for electrical energy saving in residential sector , 2003 .

[4]  K. F. Fong,et al.  Annual performance of building-integrated photovoltaic/water-heating system for warm climate application , 2009 .

[5]  Andy Walker,et al.  Analyzing Two Federal Building Integrated Photovoltaics Projects Using ENERGY-10 Simulations , 2002 .

[6]  Danny H.W. Li,et al.  A study of grid-connected photovoltaic (PV) system in Hong Kong , 2012 .

[7]  S. M. Hasnain,et al.  Need for thermal-storage air-conditioning in Saudi Arabia , 2000 .

[8]  F. D. Heidt,et al.  Evaluation of the cost efficiency of an energy efficient building , 2004 .

[9]  Liangliang Sun,et al.  Optimum design of shading-type building-integrated photovoltaic claddings with different surface azimuth angles , 2012 .

[10]  S. Tassou,et al.  Measures used to lower building energy consumption and their cost effectiveness , 2002 .

[11]  Sai On Cheung,et al.  Residential building envelope heat gain and cooling energy requirements , 2005 .

[12]  Herricos Stapountzis,et al.  Energy analysis of an improved concept of integrated PV panels in an office building in central Greece , 2011 .

[13]  Danny H.W. Li,et al.  Daylighting and its effects on peak load determination , 2005 .

[14]  Rick Hurt,et al.  Performance of a Zero-Energy House , 2008 .

[15]  Satoshi Tanishima,et al.  Polices for increasing energy efficiency: Thirty years of experience in OECD countries , 2006 .

[16]  Ricardo Rüther,et al.  Potential of building integrated photovoltaic solar energy generators in assisting daytime peaking feeders in urban areas in Brazil , 2008 .

[17]  Stephen Selkowitz,et al.  The impact of daylighting on peak electrical demand , 1984 .

[18]  Danny H.W. Li,et al.  Energy and cost analysis of semi-transparent photovoltaic in office buildings , 2009 .

[19]  S. C. Solanki,et al.  Photovoltaic modules and their applications: A review on thermal modelling , 2011 .

[20]  Yongping Yang,et al.  Performance of shape-stabilized phase change material wallboard with periodical outside heat flux waves , 2011 .

[21]  Robert F. Boehm,et al.  Modeling of phase change material peak load shifting , 2007 .

[22]  S. Ashok,et al.  Optimal cool storage capacity for load management , 2003 .

[23]  Brian Norton,et al.  Optimising the economic viability of grid-connected photovoltaic systems , 2009 .

[24]  A.W.M. van Schijndel,et al.  Reducing peak requirements for cooling by using thermally activated building systems , 2010 .

[25]  R. Judkoff,et al.  Home energy rating system building energy simulation test (HERS BESTEST): Volume 1, Tier 1 and Tier 2 tests user's manual , 1995 .

[26]  Radu Zmeureanu,et al.  Life cycle cost and energy analysis of a Net Zero Energy House with solar combisystem , 2011 .

[27]  Marc A. Rosen,et al.  A critical review of photovoltaic–thermal solar collectors for air heating , 2011 .

[28]  Tin-Tai Chow,et al.  A Review on Photovoltaic/Thermal Hybrid Solar Technology , 2010, Renewable Energy.