High bandwidth sensorless synchronisation strategies for current regulated grid connected converters

Distributed generation (DG) sources are commonly interfaced to the grid using a current regulated converter, which must be synchronized to the grid. Typically this is achieved using a phase locked loop (PLL), which must reject any harmonic distortion in the grid voltage. Conventionally this necessitates a PLL design with a low bandwidth, which then degrades the PLL's dynamic capability. In this paper an indirect or sensorless synchronization strategy is presented whereby the PLL is fed instead from the output of a stationary frame Proportional Resonant (PR) current regulator. It is shown that this structure allows for an arbitrary increase in the PLL bandwidth, with the harmonic disturbance rejection properties of the strategy further enhanced by using multiple harmonic resonators in the PR current regulator. Simulation results are presented to validate the theoretical development.

[1]  Josep M. Guerrero,et al.  Dynamics Assessment of Advanced Single-Phase PLL Structures , 2013, IEEE Transactions on Industrial Electronics.

[2]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[3]  A. G. Yepes,et al.  Three-Phase PLLs With Fast Postfault Retracking and Steady-State Rejection of Voltage Unbalance and Harmonics by Means of Lead Compensation , 2011, IEEE Transactions on Power Electronics.

[4]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[5]  M. Monfared,et al.  Design-Oriented Study of Advanced Synchronous Reference Frame Phase-Locked Loops , 2013, IEEE Transactions on Power Electronics.

[6]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[7]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[8]  Marco Liserre,et al.  An Anti-Islanding Method for Single-Phase Inverters Based on a Grid Voltage Sensorless Control , 2006, IEEE Transactions on Industrial Electronics.

[9]  Bimal K. Bose,et al.  Global Energy Scenario and Impact of Power Electronics in 21st Century , 2013, IEEE Transactions on Industrial Electronics.

[10]  J. Doval-Gandoy,et al.  Tuning of Phase-Locked Loops for Power Converters Under Distorted Utility Conditions , 2009, IEEE Transactions on Industry Applications.

[11]  V. Blasko,et al.  A novel control method of a VSC without AC line voltage sensors , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[12]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[13]  M. Liserre,et al.  Reactive Power Control for Improving Wind Turbine System Behavior Under Grid Faults , 2009, IEEE Transactions on Power Electronics.

[14]  Frede Blaabjerg,et al.  Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions , 2015, IEEE Transactions on Industry Applications.

[15]  Miguel Castilla,et al.  Control of Power Converters in AC Microgrids , 2018, Microgrids Design and Implementation.