Automatic phase determination for retrospectively gated cardiac CT.

The recent improvements in CT detector and gantry technology in combination with new heart rate adaptive cone beam reconstruction algorithms enable the visualization of the heart in three dimensions at high spatial resolution. However, the finite temporal resolution still impedes the artifact-free reconstruction of the heart at any arbitrary phase of the cardiac cycle. Cardiac phases must be found during which the heart is quasistationary to obtain outmost image quality. It is challenging to find these phases due to intercycle and patient-to-patient variability. Electrocardiogram (ECG) information does not always represent the heart motion with an adequate accuracy. In this publication, a simple and efficient image-based technique is introduced which is able to deliver stable cardiac phases in an automatic and patient-specific way. From low-resolution four-dimensional data sets, the most stable phases are derived by calculating the object similarity between subsequent phases in the cardiac cycle. Patient-specific information about the object motion can be determined and resolved spatially. This information is used to perform optimized high-resolution reconstructions at phases of little motion. Results based on a simulation study and three real patient data sets are presented. The projection data were generated using a 16-slice cone beam CT system in low-pitch helical mode with parallel ECG recording.

[1]  G D Rubin,et al.  Coronary artery angiography using multislice computed tomography images. , 2000, Circulation.

[2]  C Georg,et al.  Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. , 2001, Radiology.

[3]  Michael Grass,et al.  Cardiac image reconstruction on a 16-slice CT scanner using a retrospectively ECG-gated multicycle 3D back-projection algorithm , 2003, SPIE Medical Imaging.

[4]  M Grass,et al.  Artifact analysis of approximate helical cone-beam CT reconstruction algorithms. , 2001, Medical physics.

[5]  R. Morin,et al.  Evaluation of Reconstruction Windows for Multislice Computed Tomography in Quantification of Coronary Calcium , 2003, Investigative radiology.

[6]  J Simon,et al.  Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system. , 2003, Medical physics.

[7]  W A Kalender,et al.  ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. , 2000, Medical physics.

[8]  Y. Wang,et al.  Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. , 1999, Radiology.

[9]  Karl Stierstorfer,et al.  Cardiac spiral imaging in computed tomography without ECG using complementary projections for motion detection , 2003, SPIE Medical Imaging.

[10]  T Nielsen,et al.  Helical cardiac cone beam reconstruction using retrospective ECG gating. , 2003, Physics in medicine and biology.

[11]  R. Günther,et al.  Variation of the Coronary Calcium Score Depending on Image Reconstruction Interval and Scoring Algorithm , 2002, Investigative radiology.

[12]  Michael Grass,et al.  Artifact analysis and reconstruction improvement in helical cardiac cone beam CT , 2004, IEEE Transactions on Medical Imaging.

[13]  John P Ridgway,et al.  Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. , 2003, AJR. American journal of roentgenology.

[14]  R Haberl,et al.  A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT. , 2003, Medical physics.

[15]  C. Claussen,et al.  Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. , 2002, European heart journal.

[16]  M. Budoff,et al.  Effect of electrocardiogram triggering on reproducibility of coronary artery calcium scoring. , 2001, Radiology.

[17]  W Moshage,et al.  In-plane coronary arterial motion velocity: measurement with electron-beam CT. , 2000, Radiology.

[18]  René M. Botnar,et al.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. , 1999, Radiology.

[19]  Y Wang,et al.  Coronary MR angiography: selection of acquisition window of minimal cardiac motion with electrocardiography-triggered navigator cardiac motion prescanning--initial results. , 2001, Radiology.

[20]  T Nielsen,et al.  Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction. , 2003, Medical physics.

[21]  Ge Wang,et al.  A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging. , 2002, Medical physics.

[22]  M. Budoff,et al.  Coronary Artery Motion During the Cardiac Cycle and Optimal ECG Triggering for Coronary Artery Imaging , 2001, Investigative radiology.

[23]  Willi A Kalender,et al.  Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. , 2002, Medical physics.

[24]  M F Reiser,et al.  ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. , 2001, Radiology.

[25]  A. Weissler,et al.  Systolic Time Intervals in Heart Failure in Man , 1968, Circulation.

[26]  B. Ohnesorge,et al.  Heart Rate Adaptive Optimization of Spatial and Temporal Resolution for Electrocardiogram-Gated Multislice Spiral CT of the Heart , 2001, Journal of computer assisted tomography.

[27]  Hui Hu,et al.  Multi-slice helical CT: scan and image temporal resolution , 2000, IEEE Trans. Medical Imaging.

[28]  K Taguchi,et al.  High temporal resolution for multislice helical computed tomography. , 2000, Medical physics.

[29]  Marc Kachelriess,et al.  ECG-correlated imaging of the heart with subsecond multislice spiral CT , 2000, IEEE Transactions on Medical Imaging.