Maximum a posteriori signal recovery for optical coherence tomography angiography image generation and denoising

Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed over time and used to compute OCTA image data. OCTA data are prone to noise and artifacts caused by variations in flow speed and patient movement. We propose a novel iterative maximum a posteriori signal recovery algorithm in order to generate OCTA volumes with reduced noise and increased image quality. This algorithm is based on previous work on probabilistic OCTA signal models and maximum likelihood estimates. Reconstruction results using total variation minimization and wavelet shrinkage for regularization were compared against an OCTA ground truth volume, merged from six co-registered single OCTA volumes. The results show a significant improvement in peak signal-to-noise ratio and structural similarity. The presented algorithm brings together OCTA image generation and Bayesian statistics and can be developed into new OCTA image generation and denoising algorithms.

[1]  L. Landweber An iteration formula for Fredholm integral equations of the first kind , 1951 .

[2]  Chen D. Lu,et al.  Phase-sensitive swept-source optical coherence tomography imaging of the human retina with a vertical cavity surface-emitting laser light source. , 2013, Optics letters.

[3]  Martin Vetterli,et al.  Adaptive wavelet thresholding for image denoising and compression , 2000, IEEE Trans. Image Process..

[4]  James G. Fujimoto,et al.  Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns , 2012, Biomedical optics express.

[5]  Andreas K. Maier,et al.  Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging , 2013, IEEE Transactions on Medical Imaging.

[6]  Günter Lauritsch,et al.  Image Quality Analysis of Limited Angle Tomography Using the Shift-Variant Data Loss Model , 2016, Bildverarbeitung für die Medizin.

[7]  Christoph Neukirchen,et al.  An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach. , 2010, Medical physics.

[8]  Andreas Maier,et al.  Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction , 2012, Medical Imaging.

[9]  Gengsheng Lawrence Zeng,et al.  Medical Image Reconstruction: A Conceptual Tutorial , 2010 .

[10]  Eric M. Moult,et al.  Ultrahigh-Speed, Swept-Source Optical Coherence Tomography Angiography in Nonexudative Age-Related Macular Degeneration with Geographic Atrophy. , 2015, Ophthalmology.

[11]  Christian Riess,et al.  A Joint Probabilistic Model for Speckle Variance, Amplitude Decorrelation and Interframe Variance (IFV) Optical Coherence Tomography Angiography , 2018, Bildverarbeitung für die Medizin.

[12]  James G. Fujimoto,et al.  3-D OCT Motion Correction Efficiently Enhanced with OCT Angiography , 2018 .

[13]  Andreas K. Maier,et al.  Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets , 2015, Bildverarbeitung für die Medizin.

[14]  A. Chambolle Practical, Unified, Motion and Missing Data Treatment in Degraded Video , 2004, Journal of Mathematical Imaging and Vision.

[15]  Gaël Varoquaux,et al.  The NumPy Array: A Structure for Efficient Numerical Computation , 2011, Computing in Science & Engineering.

[16]  Emmanuelle Gouillart,et al.  scikit-image: image processing in Python , 2014, PeerJ.

[17]  Krishnan. Shankar Image quality analysis , 2009 .

[18]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[19]  Adrian Mariampillai,et al.  Speckle variance detection of microvasculature using swept-source optical coherence tomography. , 2008, Optics letters.

[20]  Joachim Hornegger,et al.  Choroidal Neovascularization Analyzed on Ultrahigh-Speed Swept-Source Optical Coherence Tomography Angiography Compared to Spectral-Domain Optical Coherence Tomography Angiography. , 2016, American journal of ophthalmology-glaucoma.

[21]  ANTONIN CHAMBOLLE,et al.  An Algorithm for Total Variation Minimization and Applications , 2004, Journal of Mathematical Imaging and Vision.

[22]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[23]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[24]  Joachim Hornegger,et al.  Wavelet denoising of multiframe optical coherence tomography data , 2012, Biomedical optics express.

[25]  Günter Lauritsch,et al.  Comparison of SART and ETV reconstruction for increased C-arm CT volume coverage by proper detector rotation in liver imaging , 2016, 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI).

[26]  Alexander Wong,et al.  General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery. , 2010, Optics express.

[27]  Martin F. Kraus,et al.  Split-spectrum amplitude-decorrelation angiography with optical coherence tomography , 2012, Optics express.

[28]  M. Nikolova An Algorithm for Total Variation Minimization and Applications , 2004 .

[29]  James G. Fujimoto,et al.  Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization , 2014, Biomedical optics express.

[30]  Andreas K. Maier,et al.  Efficient and high accuracy 3-D OCT angiography motion correction in pathology , 2021, Biomedical optics express.