An Adaptive Measurement System for the Simultaneous Evaluation of Frequency Shift and Series Resistance of QCM in Liquid
暂无分享,去创建一个
Ada Fort | Marco Mugnaini | Valerio Vignoli | Enza Panzardi | Elia Landi | Marco Tani | Pietro Vaccarella | V. Vignoli | A. Fort | Elia Landi | M. Mugnaini | E. Panzardi | M. Tani | Pietro Vaccarella
[1] J. Gordon,et al. Frequency of a quartz microbalance in contact with liquid , 1985 .
[2] Craig A. Grimes,et al. Wireless Magnetoelastic Resonance Sensors: A Critical Review , 2002 .
[3] Tommaso Addabbo,et al. Quartz-Crystal Microbalance Gas Sensors Based on TiO2 Nanoparticles , 2018, IEEE Transactions on Instrumentation and Measurement.
[4] Xianhe Huang,et al. The Exploration and Confirmation of the Maximum Mass Sensitivity of Quartz Crystal Microbalance , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.
[5] Mohieddine Benammar,et al. Quartz Crystal Microbalance Electronic Interfacing Systems: A Review , 2017, Sensors.
[6] Luis Armando Carvajal Ahumada,et al. Evaluation of Hyaluronic Acid Dilutions at Different Concentrations Using a Quartz Crystal Resonator (QCR) for the Potential Diagnosis of Arthritic Diseases , 2016, Sensors.
[7] D. Johannsmann,et al. On the Use of the Quartz Crystal Microbalance for Whole-Cell-Based Biosensing , 2018 .
[8] P. Labbé,et al. Functional characterization of starch-degrading enzymes using quartz crystal microbalance with dissipation monitoring (QCM-D) , 2013 .
[9] Andreas Dietzel,et al. Low-cost, in-liquid measuring system using a novel compact oscillation circuit and quartz-crystal microbalances (QCMs) as a versatile biosensor platform , 2017 .
[10] T. Sogorb,et al. An extended Butterworth Van Dyke model for quartz crystal microbalance applications in viscoelastic fluid media , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[11] M. Radomski,et al. The use of quartz crystal microbalance with dissipation (QCM-D) for studying nanoparticle-induced platelet aggregation , 2012, International journal of nanomedicine.
[12] Qingxia Liu,et al. QCM-D study of nanoparticle interactions. , 2016, Advances in colloid and interface science.
[13] B. Kasemo,et al. Missing mass effect in biosensor's QCM applications. , 2002, Biosensors & bioelectronics.
[14] B. Kasemo,et al. A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing. , 2009, The Review of scientific instruments.
[15] Tommaso Addabbo,et al. An AlN Micromachined Mass Sensor: Modeling and Characterization , 2021, IEEE Transactions on Instrumentation and Measurement.
[16] Eduardo Fernández,et al. Sensor Applications of Soft Magnetic Materials Based on Magneto-Impedance, Magneto-Elastic Resonance and Magneto-Electricity , 2014, Sensors.
[17] Antonio Arnau,et al. A Review of Interface Electronic Systems for AT-cut Quartz Crystal Microbalance Applications in Liquids , 2008, Sensors.
[18] Tommaso Addabbo,et al. Conditioning Circuit for Simultaneous Sensing and Actuation in Piezoelectric MEMS Resonators , 2019, 2019 IEEE Sensors Applications Symposium (SAS).
[19] Xiuming Wang,et al. Theoretical Derivation and Verification of Liquid Viscosity and Density Measurements Using Quartz Tuning Fork Sensor , 2019, 2019 Symposium on Piezoelectrcity,Acoustic Waves and Device Applications (SPAWDA).
[20] K V Santhosh,et al. Non-contact viscosity measurement using sensor fusion techniques , 2017, 2017 International Conference on Intelligent Computing, Instrumentation and Control Technologies (ICICICT).
[21] Senentxu Lanceros-Mendez,et al. Metallic Glass/PVDF Magnetoelectric Laminates for Resonant Sensors and Actuators: A Review , 2017, Sensors.
[22] Feng Tan,et al. Method for Measuring the Properties of Liquid by a Single QCM at Different Temperatures , 2018, 2018 IEEE International Frequency Control Symposium (IFCS).
[23] A. Piñón-Pazos,et al. New approach for the QCM sensors characterization , 2014 .
[24] Viscosity measurements in pulsed magnetic fields by using a quartz-crystal microbalance. , 2019, The Review of scientific instruments.
[25] L.A. Meacham,et al. The Bridge-Stabilized Oscillator , 1938, Proceedings of the Institute of Radio Engineers.
[26] H. Bissig,et al. Simultaneous measurement of the maximum oscillation amplitude and the transient decay time constant of the QCM reveals stiffness changes of the adlayer , 2003, Analytical and bioanalytical chemistry.