Superresolution parallel magnetic resonance imaging: Application to functional and spectroscopic imaging

Standard parallel magnetic resonance imaging (MRI) techniques suffer from residual aliasing artifacts when the coil sensitivities vary within the image voxel. In this work, a parallel MRI approach known as Superresolution SENSE (SURE-SENSE) is presented in which acceleration is performed by acquiring only the central region of k-space instead of increasing the sampling distance over the complete k-space matrix and reconstruction is explicitly based on intra-voxel coil sensitivity variation. In SURE-SENSE, parallel MRI reconstruction is formulated as a superresolution imaging problem where a collection of low resolution images acquired with multiple receiver coils are combined into a single image with higher spatial resolution using coil sensitivities acquired with high spatial resolution. The effective acceleration of conventional gradient encoding is given by the gain in spatial resolution, which is dictated by the degree of variation of the different coil sensitivity profiles within the low resolution image voxel. Since SURE-SENSE is an ill-posed inverse problem, Tikhonov regularization is employed to control noise amplification. Unlike standard SENSE, for which acceleration is constrained to the phase-encoding dimension/s, SURE-SENSE allows acceleration along all encoding directions--for example, two-dimensional acceleration of a 2D echo-planar acquisition. SURE-SENSE is particularly suitable for low spatial resolution imaging modalities such as spectroscopic imaging and functional imaging with high temporal resolution. Application to echo-planar functional and spectroscopic imaging in human brain is presented using two-dimensional acceleration with a 32-channel receiver coil.

[1]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[2]  Sylvia K. Plevritis,et al.  Spectral extrapolation of spatially bounded images [MRI application] , 1995, IEEE Trans. Medical Imaging.

[3]  Peter Boesiger,et al.  2D sense for faster 3D MRI , 2002, Magnetic Resonance Materials in Physics, Biology and Medicine.

[4]  L. Wald,et al.  32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry , 2006, Magnetic resonance in medicine.

[5]  P. Boesiger,et al.  Advances in sensitivity encoding with arbitrary k‐space trajectories , 2001, Magnetic resonance in medicine.

[6]  K. Uğurbil,et al.  Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling , 2004, Magnetic resonance in medicine.

[7]  Z P Liang,et al.  A generalized series approach to MR spectroscopic imaging. , 1991, IEEE transactions on medical imaging.

[8]  L. Ying,et al.  An Efficient Non-Iterative Reconstruction Algorithm for Parallel MRI with Arbitrary K-Space Trajectories , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[9]  Shi-Jiang Li,et al.  Reduction of artifacts by optimization of the sensitivity map in sensitivity‐encoded spectroscopic imaging , 2005, Magnetic resonance in medicine.

[10]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[11]  P. Boesiger,et al.  Minimum‐norm reconstruction for sensitivity‐encoded magnetic resonance spectroscopic imaging , 2006, Magnetic resonance in medicine.

[12]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[13]  O. Haraldseth,et al.  K‐space substitution: A novel dynamic imaging technique , 1993, Magnetic resonance in medicine.

[14]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[15]  Michael Elad,et al.  Restoration of a single superresolution image from several blurred, noisy, and undersampled measured images , 1997, IEEE Trans. Image Process..

[16]  Matti S Hämäläinen,et al.  Dynamic magnetic resonance inverse imaging of human brain function , 2006, Magnetic resonance in medicine.

[17]  D. Sodickson,et al.  Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations , 2003, Magnetic resonance in medicine.

[18]  S Peled,et al.  Superresolution in MRI: Application to human white matter fiber tract visualization by diffusion tensor imaging , 2001, Magnetic resonance in medicine.

[19]  B. Mueller,et al.  Signal‐to‐noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo‐planar spectroscopic imaging , 2006, Magnetic resonance in medicine.

[20]  Lawrence L. Wald,et al.  Event-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing , 2008, NeuroImage.

[21]  K. Uğurbil,et al.  NMR chemical shift imaging in three dimensions. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[22]  A. Macovski Noise in MRI , 1996, Magnetic resonance in medicine.

[23]  Karl J. Friston,et al.  Statistical parametric maps in functional imaging: A general linear approach , 1994 .

[24]  D. Sodickson,et al.  A generalized approach to parallel magnetic resonance imaging. , 2001, Medical physics.

[25]  Thomas Eickermann,et al.  A new approach to measure single‐event related brain activity using real‐time fMRI: Feasibility of sensory, motor, and higher cognitive tasks , 2001, Human brain mapping.

[26]  Fu-Nien Wang,et al.  Functional MRI using regularized parallel imaging acquisition , 2005, Magnetic resonance in medicine.

[27]  B. Rosen,et al.  Functional mapping of the human visual cortex by magnetic resonance imaging. , 1991, Science.

[28]  M. McDougall,et al.  64‐channel array coil for single echo acquisition magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[29]  P. Hansen Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion , 1987 .

[30]  K. Kwong,et al.  Parallel imaging reconstruction using automatic regularization , 2004, Magnetic resonance in medicine.

[31]  Ricardo Otazo,et al.  Accelerated short‐TE 3D proton echo‐planar spectroscopic imaging using 2D‐SENSE with a 32‐channel array coil , 2007, Magnetic resonance in medicine.

[32]  Ricardo Otazo,et al.  Sensitivity‐encoded (SENSE) proton echo‐planar spectroscopic imaging (PEPSI) in the human brain , 2007, Magnetic resonance in medicine.

[33]  Gioacchino Tedeschi,et al.  High Speed 1H Spectroscopic Imaging in Human Brain by Echo Planar Spatial‐Spectral Encoding , 1995, Magnetic resonance in medicine.