Patient-specific image-based computer simulation for theprediction of valve morphology and calcium displacement after TAVI with the Medtronic CoreValve and the Edwards SAPIEN valve.

AIMS Our aim was to validate patient-specific software integrating baseline anatomy and biomechanical properties of both the aortic root and valve for the prediction of valve morphology and aortic leaflet calcium displacement after TAVI. METHODS AND RESULTS Finite element computer modelling was performed in 39 patients treated with a Medtronic CoreValve System (MCS; n=33) or an Edwards SAPIEN XT (ESV; n=6). Quantitative axial frame morphology at inflow (MCS, ESV) and nadir, coaptation and commissures (MCS) was compared between multislice computed tomography (MSCT) post TAVI and a computer model as well as displacement of the aortic leaflet calcifications, quantified by the distance between the coronary ostium and the closest calcium nodule. Bland-Altman analysis revealed a strong correlation between the observed (MSCT) and predicted frame dimensions, although small differences were detected for, e.g., Dmin at the inflow (mean±SD MSCT vs. MODEL 21.6±2.4 mm vs. 22.0±2.4 mm; difference±SD: -0.4±1.3 mm, p<0.05) and Dmax (25.6±2.7 mm vs. 26.2±2.7 mm; difference±SD: -0.6±1.0 mm, p<0.01). The observed and predicted calcium displacements were highly correlated for the left and right coronary ostia (R2=0.67 and R2=0.71, respectively p<0.001). CONCLUSIONS Dedicated software allows accurate prediction of frame morphology and calcium displacement after valve implantation, which may help to improve outcome.

[1]  Christopher Rohkohl,et al.  Rotational angiography with motion compensation: first-in-man use for the 3D evaluation of transcatheter valve prostheses , 2015 .

[2]  Wei Sun,et al.  Simulations of transcatheter aortic valve implantation: implications for aortic root rupture , 2015, Biomechanics and modeling in mechanobiology.

[3]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: two clinical cases. , 2014, Journal of biomechanics.

[4]  P. Kirchhof,et al.  The continuum of personalized cardiovascular medicine: a position paper of the European Society of Cardiology , 2014, European heart journal.

[5]  W. O’Neill,et al.  Assessment of a novel software tool in the selection of aortic valve prosthesis size for transcatheter aortic valve replacement. , 2014, The Journal of invasive cardiology.

[6]  D. Mylotte,et al.  Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography. , 2014, JACC. Cardiovascular interventions.

[7]  J. Coselli,et al.  Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery. , 2014, Journal of the American College of Cardiology.

[8]  P. Kirchhof,et al.  Of hammers and screws: renin-angiotensin-aldosterone system inhibition to prevent atrial fibrillation in patients with hypertension. , 2014, European heart journal.

[9]  Maurice Buchbinder,et al.  Transcatheter aortic-valve replacement with a self-expanding prosthesis. , 2014, The New England journal of medicine.

[10]  P. Kirchhof,et al.  and ESC CRT R&D and European Affairs Work Shop on Personalized Medicine , 2014 .

[11]  Bernard Chevalier,et al.  Potential mechanism of annulus rupture during transcatheter aortic valve implantation , 2013, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[12]  Nassir Navab,et al.  Image-Based Computational Models for TAVI Planning: From CT Images to Implant Deployment , 2013, MICCAI.

[13]  J. Leipsic,et al.  The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. , 2013, Journal of the American College of Cardiology.

[14]  Francesco Maisano,et al.  Transcatheter aortic valve replacement in Europe: adoption trends and factors influencing device utilization. , 2013, Journal of the American College of Cardiology.

[15]  Gábor Székely,et al.  Simulation of transcatheter aortic valve implantation under consideration of leaflet calcification , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[16]  J. Leipsic,et al.  Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation. , 2013, JACC. Cardiovascular interventions.

[17]  L. Nombela‐Franco,et al.  Coronary obstruction following transcatheter aortic valve implantation: a systematic review. , 2013, JACC. Cardiovascular interventions.

[18]  Fotis Sotiropoulos,et al.  Toward patient-specific simulations of cardiac valves: state-of-the-art and future directions. , 2013, Journal of biomechanics.

[19]  S Tzamtzis,et al.  Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). , 2013, Medical engineering & physics.

[20]  S. Achenbach,et al.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). , 2012, Journal of cardiovascular computed tomography.

[21]  Alain Cribier,et al.  Transcatheter aortic valve implantation 10-year anniversary: review of current evidence and clinical implications. , 2012, European heart journal.

[22]  Wei Sun,et al.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment. , 2012, Journal of biomechanics.

[23]  M. Leon,et al.  Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. , 2012, Journal of the American College of Cardiology.

[24]  Silvia Schievano,et al.  Patient-specific simulations of transcatheter aortic valve stent implantation , 2012, Medical & Biological Engineering & Computing.

[25]  Stuart J Pocock,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[26]  Helko Lehmann,et al.  euHeart: personalized and integrated cardiac care using patient-specific cardiovascular modelling , 2011, Interface Focus.

[27]  B. Carabello Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery , 2011, Current cardiology reports.

[28]  Friedhelm Beyersdorf,et al.  Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[29]  Jeroen J. Bax,et al.  Comparison of Aortic Root Dimensions and Geometries Before and After Transcatheter Aortic Valve Implantation by 2- and 3-Dimensional Transesophageal Echocardiography and Multislice Computed Tomography , 2010, Circulation. Cardiovascular imaging.

[30]  Nico Mollet,et al.  Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. , 2009, Journal of the American College of Cardiology.