A fundamental study on the impact of HVDC lines on transient stability of power systems

An increasing number of HVDC lines are currently deployed all around the world. HVDC links are either based on line-commutated converters (LCC) or on voltage-source converters (VSC) technologies. This paper presents a fundamental study on the impact of HVDC links on the transient stability of power systems. Both, VSC and LCC HVDC links have been studied when applied to a two-area power system. Particular attention has been paid to the critical clearing time (CCT). It has been found that HVDC links generally improve transient stability by increasing the critical clearing time with respect to the case without HVDC link. Moreover, the impact on transient stability significantly depends on the supervisory control strategies applied to the LCCs and VSCs of the HVDC links. An inappropriate handling of current limits of VSC by reducing either active or reactive power can worsen transient stability.

[1]  Lin Guan,et al.  Study on a new power modulation strategy of HVDC to improve transient stability in China Southern Power Grid , 2013, 2013 1st International Future Energy Electronics Conference (IFEEC).

[2]  G. J. Rogers,et al.  Analytical investigation of factors influencing power system stabilizers performance , 1992 .

[3]  Zhe Chen,et al.  Transient voltage stability analysis and improvement of a network with different HVDC systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[4]  ShiEn He,et al.  Comparative analysis on critical clearing time of power system connected with large wind farm , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[5]  Ronnie Belmans,et al.  Generalized Dynamic VSC MTDC Model for Power System Stability Studies , 2010, IEEE Transactions on Power Systems.

[6]  IEEE Report Dynamic Performance Characteristics of North American HVDC Systems for Transient and Dynamic Stability Evaluations , 1981, IEEE Transactions on Power Apparatus and Systems.

[7]  Zheng Xu,et al.  Impacts of three MMC-HVDC configurations on AC system stability under DC line faults , 2015, 2015 IEEE Power & Energy Society General Meeting.

[8]  Y. Phulpin,et al.  HVDC control strategies to improve transient stability in interconnected power systems , 2009, 2009 IEEE Bucharest PowerTech.

[9]  Claus Leth Bak,et al.  Transient stability assessment of power system with large amount of wind power penetration: The Danish case study , 2012, 2012 10th International Power & Energy Conference (IPEC).

[10]  K A Folly,et al.  Interaction between HVAC - HVDC system: Impact of line length on transient stability , 2010, 45th International Universities Power Engineering Conference UPEC2010.

[11]  Ronnie Belmans,et al.  Modeling of Multi-Terminal VSC HVDC Systems With Distributed DC Voltage Control , 2014, IEEE Transactions on Power Systems.

[12]  Mario Ndreko,et al.  Transient stability analysis of an onshore power system with multi-terminal offshore VSC-HVDC transmission: A case study for the Netherlands , 2013, 2013 IEEE Power & Energy Society General Meeting.

[13]  Jiuping Pan,et al.  Stability Analysis of VSC MTDC Grids Connected to Multimachine AC Systems , 2011, IEEE Transactions on Power Delivery.

[14]  W. Long,et al.  HVDC transmission: yesterday and today , 2007, IEEE Power and Energy Magazine.

[15]  N. Fernandopulle,et al.  Incorporation of detailed HVDC dynamics into transient energy functions , 2005, IEEE Transactions on Power Systems.

[16]  Lidong Zhang,et al.  Power System Reliability and Transfer Capability Improvement by VSC-HVDC ( HVDC Light © ) , 2007 .

[17]  Dirk Van Hertem,et al.  Influence of VSC HVDC on transient stability: Case study of the Belgian grid , 2010, IEEE PES General Meeting.

[18]  Mehrdad Ghandhari,et al.  Improvement of power system stability by using a VSC-HVdc ☆ , 2011 .

[19]  J. Jatskevich,et al.  Dynamic Averaged and Simplified Models for MMC-Based HVDC Transmission Systems , 2013, IEEE Transactions on Power Delivery.

[20]  Oriol Gomis-Bellmunt,et al.  Modeling and control of HVDC grids: A key challenge for the future power system , 2014, 2014 Power Systems Computation Conference.

[21]  Robert Eriksson,et al.  Coordinated Control of Multiterminal DC Grid Power Injections for Improved Rotor-Angle Stability Based on Lyapunov Theory , 2014, IEEE Transactions on Power Delivery.

[22]  Ronnie J. M. Belmans,et al.  A proposal for standard VSC HVDC dynamic models in power system stability studies , 2011 .

[23]  S.P. Chowdhury,et al.  Effect of converter DC fault on the transient stability of a Multi-Machine Power System with HVDC transmission lines , 2009, AFRICON 2009.

[24]  S. Chowdhury,et al.  Investigation of voltage and transient stability of HVAC network in hybrid with VSC-HVDC and HVDC Link , 2010, 45th International Universities Power Engineering Conference UPEC2010.

[25]  Hongyang Huang,et al.  Transient stability analysis of Shanghai Power Grid with multiple HVDC links , 2010, 2010 International Conference on Power System Technology.

[26]  Zheng Xu,et al.  Impacts of Three MMC-HVDC Configurations on AC System Stability Under DC Line Faults , 2015, IEEE Transactions on Power Systems.