Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

IMPORTANCE To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. OBJECTIVE To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. DESIGN AND SETTING Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. INTERVENTIONS Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. MAIN OUTCOMES AND MEASURES Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. RESULTS With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. CONCLUSIONS AND RELEVANCE To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.

[1]  Jonathan M Sorger,et al.  Toward intraoperative image-guided transoral robotic surgery , 2013, Journal of Robotic Surgery.

[2]  M. D. Olson,et al.  The prevalence and clinical course of facial nerve paresis following cochlear implant surgery , 2013, The Laryngoscope.

[3]  Marco Caversaccio,et al.  A self-developed and constructed robot for minimally invasive cochlear implantation , 2012, Acta oto-laryngologica.

[4]  Masaru Ishii,et al.  A clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery , 2012, Medical Imaging.

[5]  Kouhei Ohnishi,et al.  Telerobotic-assisted bone-drilling system using bilateral control with feed operation scaling and cutting force scaling , 2012, The international journal of medical robotics + computer assisted surgery : MRCAS.

[6]  Seung Hwan Lee,et al.  Image-guided robotic mastoidectomy using human-robot collaboration control , 2011, 2011 IEEE International Conference on Mechatronics and Automation.

[7]  Gregory D. Hager,et al.  Handheld micromanipulation with vision-based virtual fixtures , 2011, 2011 IEEE International Conference on Robotics and Automation.

[8]  Russell H. Taylor,et al.  High-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery , 2011, Medical Imaging.

[9]  C. Linstrom,et al.  Revision Cochlear Implant Surgery in Patients With Suspected Soft Failures , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[10]  J. Ding,et al.  Inroads Toward Robot-Assisted Cochlear Implant Surgery Using Steerable Electrode Arrays , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[11]  S Baron,et al.  Percutaneous inner-ear access via an image-guided industrial robot system , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  R. Balachandran,et al.  Percutaneous cochlear implant drilling via customized frames: An in vitro study , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[13]  Omid Majdani,et al.  Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model , 2010, International Journal of Computer Assisted Radiology and Surgery.

[14]  R. Labadie,et al.  Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool , 2010, Acta oto-laryngologica.

[15]  Daniel Mirota,et al.  Toward Video-Based Navigation for Endoscopic Endonasal Skull Base Surgery , 2009, MICCAI.

[16]  Omid Majdani,et al.  Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology , 2009, Acta oto-laryngologica.

[17]  Bodo Heimann,et al.  A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study , 2009, International Journal of Computer Assisted Radiology and Surgery.

[18]  F. Telischi,et al.  Incidence and indications for revision cochlear implant surgery in adults and children , 2009, The Laryngoscope.

[19]  Jian Zhang,et al.  Path Planning and Workspace Determination for Robot-Assisted Insertion of Steerable Electrode Arrays for Cochlear Implant Surgery , 2008, MICCAI.

[20]  P. Brett,et al.  An autonomous surgical robot for drilling a cochleostomy: preliminary porcine trial , 2008, Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery.

[21]  Omid Majdani,et al.  Clinical Validation of Percutaneous Cochlear Implant Surgery: Initial Report , 2008, The Laryngoscope.

[22]  C. Buchman,et al.  Scala Tympani Cochleostomy I: Results of a Survey , 2007, The Laryngoscope.

[23]  Andreas Radeloff,et al.  Scala Tympani Cochleostomy II: Topography and Histology , 2007, The Laryngoscope.

[24]  P.N. Brett,et al.  A surgical robot for cochleostomy , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  C. G. Wright,et al.  Cochlear Implant Electrode Insertion: The Round Window Revisited , 2007, The Laryngoscope.

[26]  Thomas Klenzner,et al.  Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults , 2007, Ear and hearing.

[27]  Margaret W Skinner,et al.  In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea , 2007, The Annals of otology, rhinology & laryngology. Supplement.

[28]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[29]  E. Reardon,et al.  The impact of image-guidance systems on sinus surgery. , 2005, Otolaryngologic clinics of North America.

[30]  Michael Tykocinski,et al.  Cochleostomy site: Implications for electrode placement and hearing preservation , 2005, Acta oto-laryngologica.

[31]  Allison M. Okamura,et al.  Speed-Accuracy Characteristics of Human-Machine Cooperative Manipulation Using Virtual Fixtures With Variable Admittance , 2004, Hum. Factors.

[32]  Dominik Henrich,et al.  Development of the First Force‐Controlled Robot for Otoneurosurgery , 2003, The Laryngoscope.

[33]  R. Metson,et al.  Physician Experience With an Optical Image Guidance System for Sinus Surgery , 2000, The Laryngoscope.

[34]  Bin Zheng,et al.  Effects of assembling virtual fixtures on learning a navigation task. , 2006, Studies in health technology and informatics.

[35]  Jing Ren,et al.  Rendering of virtual fixtures for MIS using generalized sigmoid functions. , 2006, Studies in health technology and informatics.