Handheld Optical System for Pectus Excavatum Assessment

Disruptive 3D technologies, such as reverse engineering (RE) and additive manufacturing (AM), when applied in the medical field enable the development of new methods for personalized and non-invasive treatments When referring to the monitoring of pectus excavatum, one of the most common thoracic malformations, 3D acquisition of the patient chest proved to be a straightforward method for assessing and measuring chest deformation Unfortunately, such systems are usually available in a dedicated facility, can be operated only by specialized doctors with the support of engineers and can be used only with patients on site It is therefore impossible to perform any routine check-up when the patient is unable to reach the outpatient clinic The COVID19 pandemic situation has placed even greater restrictions on patient mobility, worsening this problem To deal with this issue, a new low-cost portable optical scanner for monitoring pectus excavatum is proposed in this work The scanner, named Thor 2 0, allows a remote diagnostic approach, offering the possibility to perform routine check-ups telematically Usability tests confirmed the user-friendly nature of the devised system The instrument was used at the Meyer Children’s Hospital (Florence, Italy) chest-malformations center to treat PE patients The performed measurements proved to be in line with the current state of the art © 2021 by the authors Licensee MDPI, Basel, Switzerland

[1]  J. Paulson,et al.  Nonoperative management of pectus excavatum with vacuum bell therapy: A single center study. , 2018, Journal of pediatric surgery.

[2]  Frank-Martin Haecker,et al.  Vacuum bell therapy. , 2016, Annals of cardiothoracic surgery.

[3]  F. Frantz Indications and guidelines for pectus excavatum repair , 2011, Current opinion in pediatrics.

[4]  Robert Sitnik,et al.  Method of pectus excavatum measurement based on structured light technique. , 2009, Journal of biomedical optics.

[5]  Kathleen S. McGreevy,et al.  A Novel Objective Approach to the External Measurement of Pectus Excavatum Severity by Means of an Optical Device. , 2018, The Annals of thoracic surgery.

[6]  A. Sandler,et al.  Management of congenital chest wall deformities. , 2011, Seminars in plastic surgery.

[7]  Monica Carfagni,et al.  Metrological and Critical Characterization of the Intel D415 Stereo Depth Camera , 2018, Sensors.

[8]  Olivier Tiffet,et al.  New Methods for Imaging Evaluation of Chest Wall Deformities , 2017, Front. Pediatr..

[9]  M. Pfaundler,et al.  Chirurgie und Orthopädie im Kindesalter , 1915 .

[10]  E. Habermann,et al.  Minimal cosmetic revision required after minimally invasive pectus repair , 2018, Pediatric Surgery International.

[11]  F. Haecker,et al.  Non-surgical treatment of pectus excavatum. , 2016, Journal of visualized surgery.

[12]  F. Häcker Nonsurgical Treatment of Chest Wall Deformities: Contradiction or Complement? , 2018, European Journal of Pediatric Surgery.

[13]  J. Wall,et al.  3D Optical Imaging for Pectus Excavatum Assessment. , 2019, The Annals of thoracic surgery.

[14]  Christoph Brochhausen,et al.  Pectus excavatum: history, hypotheses and treatment options. , 2012, Interactive cardiovascular and thoracic surgery.

[15]  Francesca Uccheddu,et al.  Outpatient monitoring of Pectus Excavatum: a Neural Network-based approach , 2020, 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC).

[16]  M. Tedde,et al.  The Vacuum Bell device as a sternal lifter: An immediate effect even with a short time use. , 2017, Journal of pediatric surgery.

[17]  Alain Abran,et al.  Usability Meanings and Interpretations in ISO Standards , 2003, Software Quality Journal.

[18]  Frank-Martin Haecker,et al.  The vacuum bell for conservative treatment of pectus excavatum: the Basle experience , 2011, Pediatric Surgery International.

[19]  Jakob Nielsen,et al.  A mathematical model of the finding of usability problems , 1993, INTERCHI.

[20]  Janet L Ronsky,et al.  Clinical impact of optical imaging with 3-D reconstruction of torso topography in common anterior chest wall anomalies. , 2007, Journal of pediatric surgery.

[21]  M. Martínez-Ferro,et al.  Dynamic compression system for the correction of pectus carinatum. , 2008, Seminars in pediatric surgery.

[22]  N. Steuerwald,et al.  Anatomical, histologic, and genetic characteristics of congenital chest wall deformities. , 2009, Seminars in thoracic and cardiovascular surgery.

[23]  A. Messineo,et al.  Towards a Non-invasive Pectus Excavatum Severity Assessment Tool Using a Linear Discriminant Analysis on 3D Optical Data , 2019, Lecture Notes in Mechanical Engineering.

[24]  Frederic Costes,et al.  Preliminary study of efficacy of cup suction in the correction of typical pectus excavatum. , 2016, Journal of pediatric surgery.

[25]  L. Faulkner Beyond the five-user assumption: Benefits of increased sample sizes in usability testing , 2003, Behavior research methods, instruments, & computers : a journal of the Psychonomic Society, Inc.

[26]  F. Schier,et al.  The vacuum chest wall lifter: an innovative, nonsurgical addition to the management of pectus excavatum. , 2005, Journal of pediatric surgery.