Single-centre experience on endocardial and epicardial pacemaker system function in neonates and infants.

AIMS Endocardial (ENDO) or epicardial (EPI) pacing systems are implanted in infants but it remains unclear which system should be preferred. METHODS AND RESULTS We evaluated the results of children <or=1 year who underwent pacemaker (PM) implantation at our centre with a retrospective analysis. Between 1992 and 2004, 56 patients, 37 of whom had other congenital heart defects (CHDs), received a PM at 4.4 +/- 3.8 months of age for atrioventricular block (n = 52) and sinus node dysfunction. Rate-responsive ventricular demand pacing (VVIR) PMs were implanted in 25 patients (19 ENDO), dual-chamber demand pacing (DDD) in 29, and rate-responsive atrial demand pacing (AAIR) in 2 (all EPI). Follow-up (FU) was 4.5 +/- 3.5 (range 0.3-13) years: 15 pacing system failures occurred among the 56 patients (26%) after 4.5 +/- 3.2 years, with a significantly reduced success rate for EPI (21-fold increase of the risk of failure) and complex CHD. Also in patients without surgery for CHD, EPI showed a worse outcome. Among the 91 leads implanted, failures occurred more significantly in EPI (18% of atrial, 24% of ventricular leads) than in ENDO (5% of ventricular leads). No venous occlusion was found at FU. CONCLUSIONS Single-lead, VVIR ENDO pacing had higher efficiency and safety than EPI, and it might be the best choice for PM implantation in infants. However, because of small patient numbers and lack of longer FU, these findings should be treated with caution.

[1]  F. Drago,et al.  Upgrading of VVIR Pacemakers with Nonfunctional Endocardial Ventricular Leads to VDD Pacemakers in Adolescents , 2006, Pacing and clinical electrophysiology : PACE.

[2]  L. Ravà,et al.  Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patients. , 2006, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[3]  J. Triedman,et al.  Comparison of Modern Steroid-Eluting Epicardial and Thin Transvenous Pacemaker Leads in Pediatric and Congenital Heart Disease Patients , 2005, Journal of Interventional Cardiac Electrophysiology.

[4]  L. Davidovic,et al.  Prevalence of Venous Obstruction in Permanent Endovenous Pacing in Newborns and Infants: Follow‐Up Study , 2005, Pacing and clinical electrophysiology : PACE.

[5]  P. Karpawich,et al.  Effectiveness of transvenous pacemaker leads placed through intravascular stents in patients with congenital heart disease. , 2005, The American journal of cardiology.

[6]  M. Alexander Transvenous Pacing in Infants: , 2004, Pacing and clinical electrophysiology : PACE.

[7]  E. Rosenthal,et al.  Endocardial Pacemaker Implantation in Infants Weighing ≤ 10 Kilograms , 2004, Pacing and clinical electrophysiology : PACE.

[8]  F. Drago,et al.  Upgrade of Single Chamber Pacemakers with Transvenous Leads to Dual Chamber Pacemakers in Pediatric and Young Adult Patients , 2004, Pacing and clinical electrophysiology : PACE.

[9]  John K Triedman,et al.  Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease. , 2004, Heart rhythm.

[10]  H. Walters,et al.  Chronic Performance of Steroid‐Eluting Epicardial Leads in a Growing Pediatric Population: , 2003, Pacing and clinical electrophysiology : PACE.

[11]  P. Karpawich,et al.  Single Versus Dual Chamber Pacing in the Young: , 2003, Pacing and clinical electrophysiology : PACE.

[12]  J. Crosson,et al.  Endocardial and epicardial steroid lead pacing in the neonatal and paediatric age group , 2002, Heart.

[13]  J. William Gaynor,et al.  Permanent Epicardial Pacing in Pediatric Patients: Seventeen Years of Experience and 1200 Outpatient Visits , 2001, Circulation.

[14]  L. Iserin,et al.  Characteristics and Results of Epicardial Pacing in Neonates and Infants , 2000, Pacing and clinical electrophysiology : PACE.

[15]  Massimo Zoni Berisso,et al.  Linee guida ANMCO-SIC-AIAC sull'uso appropriato delle metodiche di elettrostimolazione cardiaca definitiva , 2000 .

[16]  S. Daebritz,et al.  Twenty years experience with pediatric pacing: epicardial and transvenous stimulation. , 2000, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  A. Raviele,et al.  Experience with a Low Profile Bipolar, Active Fixation Pacing Lead in Pediatric Patients , 1999, Pacing and clinical electrophysiology : PACE.

[18]  J. Hartikainen,et al.  Complications Related to Permanent Pacemaker Therapy , 1999, Pacing and clinical electrophysiology : PACE.

[19]  M. Bink-Boelkens,et al.  Comparison of longevity, pacing, and sensing characteristics of steroid-eluting epicardial versus conventional endocardial pacing leads in children. , 1999, The Journal of thoracic and cardiovascular surgery.

[20]  M A Hlatky,et al.  ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive Summary--a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). , 1998, Circulation.

[21]  S. Pavlovic,et al.  Absorbable Suture Technique: Solution to the Growth Problem in Pediatric Pacing with Endocardial Leads , 1998, Pacing and clinical electrophysiology : PACE.

[22]  R. Gibbons,et al.  ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). , 1998, Journal of the American College of Cardiology.

[23]  E. Rosenthal,et al.  Use of an Atrial Loop to Extend the Duration of Endocardial Pacing in a Neonate , 1997, Pacing and clinical electrophysiology : PACE.

[24]  B. McCrindle,et al.  Risk Factors for Venous Obstruction in Children with Transvenous Pacing Leads , 1997, Pacing and clinical electrophysiology : PACE.

[25]  J. Molina,et al.  Implantation of transvenous pacemakers in infants and small children. , 1995, The Annals of thoracic surgery.

[26]  A. Turchetta,et al.  Efficacy and Safety of Ventricular Rate Responsive Pacing in Children with Complete Atrioventricular Block , 1994, Pacing and clinical electrophysiology : PACE.

[27]  P. Gillette,et al.  Actuarial Survival of Transvenous Pacing Leads in a Pediatric Population , 1993, Pacing and clinical electrophysiology : PACE.

[28]  C. Noh,et al.  Permanent Epicardial Pacing in Pediatric Patients , 1992 .

[29]  J. Mason,et al.  Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Committee on Pacemaker Implantation). , 1991, Journal of the American College of Cardiology.

[30]  Richard P. Lewis,et al.  ACC/AHA PRACTICE GUIDELINES ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices , 2016 .