Emergency Polytetrafluoroethylene-Covered Stent Implantation to Treat Coronary Ruptures

Background—Coronary perforation is a life-threatening complication of percutaneous interventions. In the past few years, the implantation of covered stents has emerged as a strategy for treatment when the traditional conservative approach (ie, prolonged balloon inflation and reversal of anticoagulation) fails. Methods and Results—Since May 1997 (when polytetrafluoroethylene [PTFE]-covered stents were available at our institutions), 11 of the 12 consecutive patients who had coronary ruptures that were unsuccessfully sealed with prolonged balloon inflation and reversal of anticoagulation were treated with 12 PTFE-covered stents (PTFE group). The efficacy of the PTFE-covered stent was compared with that of noncovered stents, which were used to treat 17 perforations (non-PTFE group). One patient sustained a very distal perforation that was not suitable for covered stent sealing and underwent emergency surgery. All vessel ruptures treated with PTFE-covered stent implantation were successfully sealed. The time necessary to deploy the stent was 10±3 minutes (range, 4 to 15 minutes). All patients but one were discharged from the hospital and had an optimal early clinical outcome. One patient underwent emergency bypass surgery and died in the intensive care unit. The occurrence of cardiac tamponade and the necessity for emergency surgery was significantly lower in the PTFE group than in the non-PTFE group. At 14±4 months, the 10 discharged patients had not experienced any major adverse cardiac events. Conclusions—This preliminary study supports the utility of the PTFE-covered stent for the nonsurgical treatment of vessel ruptures.

[1]  R. Caputo,et al.  Successful treatment of a saphenous vein graft perforation with an autologous vein‐covered stent , 1999, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  F. Werner,et al.  Successful treatment of coronary artery perforation during angioplasty using a new membrane-coated stent. , 1999, The Journal of invasive cardiology.

[3]  A. Zeiher,et al.  Coronary stent grafts covered by a polytetrafluoroethylene membrane. , 1999, The American journal of cardiology.

[4]  C. Di Mario,et al.  Administration of protamine after coronary stent deployment. , 1999, American heart journal.

[5]  D. Ramsdale,et al.  Repair of coronary artery perforation after rotastenting by implantation of the JoStent covered stent. , 1998, Catheterization and cardiovascular diagnosis.

[6]  C. Di Mario,et al.  Successful closure of a coronary vessel rupture with a vein graft stent: case report. , 1996, Catheterization and cardiovascular diagnosis.

[7]  C. Vlachopoulos,et al.  Autologous vein graft-coated stent for treatment of coronary artery disease. , 1996, Catheterization and cardiovascular diagnosis.

[8]  S. Ellis,et al.  Increased Coronary Perforation in the New Device Era: Incidence, Classification, Management, and Outcome , 1994, Circulation.

[9]  W. O’Neill,et al.  Perforations after percutaneous coronary interventions: clinical, angiographic, and therapeutic observations. , 1994, Catheterization and cardiovascular diagnosis.

[10]  M. Leon,et al.  Coronary perforation after excimer laser coronary angioplasty: the Excimer Laser Coronary Angioplasty Registry experience. , 1994, Journal of the American College of Cardiology.