Optimization algorithm for overlapping-field plans of scanned ion beam therapy with reduced sensitivity to range and setup uncertainties

A 'patch-field' strategy is often used for tumors with large volumes exceeding the available field size in passive irradiations with ion beams. Range and setup errors can cause hot and cold spots at the field junction within the target. Such errors will also displace the field to miss the target periphery. With scanned ion beams with fluence modulation, the two junctional fields can be overlapped rather than patched, which may potentially reduce the sensitivity to these uncertainties. In this study, we have developed such a robust optimization algorithm. This algorithm is composed of the following two steps: (1) expanding the target volume with margins against the uncertainties, and (2) solving the inverse problem where the terms suppressing the dose gradient of individual fields are added into the objective function. The validity of this algorithm is demonstrated through simulation studies for two extreme cases of two fields with unidirectional and opposing geometries and for a prostate-cancer case. With the proposed algorithm, we can obtain a more robust plan with minimized influence of range and setup uncertainties than the conventional plan. Compared to conventional optimization, the calculation time for the robust optimization increased by a factor of approximately 3.

[1]  Radhe Mohan,et al.  A novel patch-field design using an optimized grid filter for passively scattered proton beams , 2007, Physics in medicine and biology.

[2]  H. Tsujii,et al.  Cervical spine osteosarcoma treated with carbon-ion radiotherapy. , 2006, The Lancet. Oncology.

[3]  M. Bussière,et al.  Treatment Planning for Conformal Proton Radiation Therapy , 2003, Technology in cancer research & treatment.

[4]  Shinji Sato,et al.  Field-size effect of physical doses in carbon-ion scanning using range shifter plates. , 2009, Medical physics.

[5]  Takuji Furukawa,et al.  Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model , 2010, Physics in medicine and biology.

[6]  Shinji Sato,et al.  Development of treatment planning for scanning irradiation at HIMAC , 2008 .

[7]  U Oelfke,et al.  Worst case optimization: a method to account for uncertainties in the optimization of intensity modulated proton therapy , 2008, Physics in medicine and biology.

[8]  Shinji Sato,et al.  Optimization for fast-scanning irradiation in particle therapy. , 2007, Medical physics.

[9]  Katia Parodi,et al.  Clinical implementation of full Monte Carlo dose calculation in proton beam therapy , 2008, Physics in medicine and biology.

[10]  Timothy C Y Chan,et al.  Accounting for range uncertainties in the optimization of intensity modulated proton therapy , 2007, Physics in medicine and biology.

[11]  Gudrun Goitein,et al.  The clinical potential of intensity modulated proton therapy. , 2004, Zeitschrift fur medizinische Physik.

[12]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[13]  G. Chen,et al.  Treatment planning for heavy ion radiotherapy. , 1979, International journal of radiation oncology, biology, physics.

[14]  E. Pedroni,et al.  Intensity modulated proton therapy: a clinical example. , 2001, Medical physics.

[15]  Thomas Bortfeld,et al.  Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning. , 2008, Medical physics.

[16]  O Jäkel,et al.  Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization. , 2000, Physics in medicine and biology.

[17]  A J Lomax,et al.  Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions , 2008, Physics in medicine and biology.

[18]  Shinichiro Mori,et al.  Effects of intrafractional motion on water equivalent pathlength in respiratory-gated heavy charged particle beam radiotherapy. , 2007, International journal of radiation oncology, biology, physics.