Load bearing and stiffness tailored NiTi implants produced by additive manufacturing: a simulation study

Common metals for stable long-term implants (e.g. stainless steel, Titanium and Titanium alloys) are much stiffer than spongy cancellous and even stiffer than cortical bone. When bone and implant are loaded this stiffness mismatch results in stress shielding and as a consequence, degradation of surrounding bony structure can lead to disassociation of the implant. Due to its lower stiffness and high reversible deformability, which is associated with the superelastic behavior, NiTi is an attractive biomaterial for load bearing implants. However, the stiffness of austenitic Nitinol is closer to that of bone but still too high. Additive manufacturing provides, in addition to the fabrication of patient specific implants, the ability to solve the stiffness mismatch by adding engineered porosity to the implant. This in turn allows for the design of different stiffness profiles in one implant tailored to the physiological load conditions. This work covers a fundamental approach to bring this vision to reality. At first modeling of the mechanical behavior of different scaffold designs are presented as a proof of concept of stiffness tailoring. Based on these results different Nitinol scaffolds can be produced by additive manufacturing.

[1]  Mitsuo Niinomi,et al.  Biocompatibility of Ti-alloys for long-term implantation. , 2013, Journal of the mechanical behavior of biomedical materials.

[2]  M. Elahinia,et al.  Manufacturing and processing of NiTi implants: A review , 2012 .

[3]  Michael A K Liebschner,et al.  Biomechanical considerations of animal models used in tissue engineering of bone. , 2004, Biomaterials.

[4]  C. L. Chu,et al.  Fabrication of porous NiTi shape memory alloy for hard tissue implants by combustion synthesis , 2004 .

[5]  D. Lagoudas,et al.  A thermodynamical constitutive model for shape memory materials. Part I. The monolithic shape memory alloy , 1996 .

[6]  R Langer,et al.  Novel approach to fabricate porous sponges of poly(D,L-lactic-co-glycolic acid) without the use of organic solvents. , 1996, Biomaterials.

[7]  Xianjin Yang,et al.  Effect of porous NiTi alloy on bone formation: A comparative investigation with bulk NiTi alloy for 15 weeks in vivo , 2008 .

[8]  Joo L. Ong,et al.  Diffusion in Musculoskeletal Tissue Engineering Scaffolds: Design Issues Related to Porosity, Permeability, Architecture, and Nutrient Mixing , 2004, Annals of Biomedical Engineering.

[9]  D. Dunand,et al.  Shape-memory NiTi with two-dimensional networks of micro-channels. , 2011, Acta biomaterialia.

[10]  Bingyun Li,et al.  Microstructure and superelasticity of porous NiTi alloy , 1999 .

[11]  Saroja Ramanujan,et al.  Diffusion and convection in collagen gels: implications for transport in the tumor interstitium. , 2002, Biophysical journal.

[12]  Abhay Pandit,et al.  Fabrication methods of porous metals for use in orthopaedic applications. , 2006, Biomaterials.

[13]  J. Galante,et al.  ESB Research Award 1992. The mechanism of bone remodeling and resorption around press-fitted THA stems. , 1993, Journal of biomechanics.

[14]  Shih-Ching Wu,et al.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities. , 2003, Biomaterials.

[15]  Farzam Farahmand,et al.  Aseptic loosening of femoral components – A review of current and future trends in materials used , 2012 .

[16]  A. Pelton,et al.  An overview of nitinol medical applications , 1999 .

[17]  B Vamsi Krishna,et al.  Low stiffness porous Ti structures for load-bearing implants. , 2007, Acta biomaterialia.

[18]  D. Dunand,et al.  High strength, low stiffness, porous NiTi with superelastic properties. , 2005, Acta Biomaterialia.

[19]  L. Rong,et al.  The influence of porosity on corrosion characteristics of porous NiTi alloy in simulated body fluid , 2002 .

[20]  S. Stupp,et al.  Porous NiTi for bone implants: a review. , 2008, Acta biomaterialia.