An Inexpensive, Stable, and Accurate Relative Humidity Measurement Method for Challenging Environments

In this research, an improved psychrometer is developed to solve practical issues arising in the relative humidity measurement of challenging drying environments for meat manufacturing in agricultural and agri-food industries. The design in this research focused on the structure of the improved psychrometer, signal conversion, and calculation methods. The experimental results showed the effect of varying psychrometer structure on relative humidity measurement accuracy. An industrial application to dry-cured meat products demonstrated the effective performance of the improved psychrometer being used as a relative humidity measurement sensor in meat-drying rooms. In a drying environment for meat manufacturing, the achieved measurement accuracy for relative humidity using the improved psychrometer was ±0.6%. The system test results showed that the improved psychrometer can provide reliable and long-term stable relative humidity measurements with high accuracy in the drying system of meat products.

[1]  Boris Igor Palella,et al.  On the management and prevention of heat stress for crews onboard ships , 2016 .

[2]  Andreas Demosthenous,et al.  A CMOS Smart Temperature and Humidity Sensor with Combined Readout , 2014, Sensors.

[3]  Anton Pletersek,et al.  Humidity Sensors Printed on Recycled Paper and Cardboard , 2014, Sensors.

[4]  B. Palella,et al.  On the problems related to natural wet bulb temperature indirect evaluation for the assessment of hot thermal environments by means of WBGT. , 2012, The Annals of occupational hygiene.

[5]  S. A. Giner,et al.  Relative humidity errors when measuring dry and wet bulb temperatures , 2011 .

[6]  Ren Kun,et al.  Design of Intelligent Dry and Wet Bulb Humidity Sensor , 2011 .

[7]  F. Tanaka,et al.  Development of thick layer re-wetting model for brown rice packaged with LDPE and PBT films , 2010 .

[8]  Michael J. Savage,et al.  Field Evaluation of Polymer Capacitive Humidity Sensors for Bowen Ratio Energy Balance Flux Measurements , 2010, Sensors.

[9]  Mart H. M. Grooten,et al.  High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air , 2010, Sensors.

[10]  Poritosh Roy,et al.  Hot Air Drying Characteristics of Sweet Potato Using Moisture Sorption Isotherm Analysis and Its Quality Changes During Drying , 2010 .

[11]  Y. T. Puyate,et al.  Effects of Drying Parameters on the Drying Kinetics of Fermented Ground Cassava Using a Rotary Dryer , 2010 .

[12]  S. Das,et al.  Texture Profile Analysis of Cooked Sun Dried Nuggets (Bori) Prepared with Different Levels of Moisture Content and Percent Air Incorporation in Its Batter , 2007 .

[13]  Somchart Soponronnarit,et al.  Comparative study of different combined superheated-steam drying techniques for chicken meat , 2007 .

[14]  王祖浩 孙丹儿 杨惠仙 Chemistry:The Molecular Nature of Matter and Change评述 , 2007 .

[15]  R. Montanini Wavelength-encoded optical psychrometer for relative humidity measurement. , 2007, The Review of scientific instruments.

[16]  Handarto,et al.  A Method for measuring Dry-bulb Temperatures during the Operation of a Fog System for Greenhouse Cooling , 2006 .

[17]  Denis Bruneau,et al.  Drying and smoking of meat: heat and mass transfer modeling and experimental analysis , 2005 .

[18]  Chen Yong,et al.  The application of the software package for humidity conversion in the calculation fields of psychrometer , 2004 .

[19]  Gauri S. Mittal,et al.  Artificial Neural Network-based Psychrometric Predictor , 2003 .

[20]  M. Maskan,et al.  Hot air and sun drying of grape leather (pestil) , 2002 .

[21]  H. Guo,et al.  A procedure to evaluate humidity sensor performance under livestock housing conditions , 2001 .

[22]  P. R. Wiederhold Water Vapor Measurement: Methods and Instrumentation , 1997 .

[23]  Manabendra Bhuyan,et al.  An on-line method for monitoring of relative humidity using thermal sensors , 1995, Proceedings of IEEE/IAS International Conference on Industrial Automation and Control.

[24]  E. L. Nichols,et al.  An automatic psychrometer sensor for poultry farming , 1992, Proceedings IEEE Southeastcon '92.

[25]  Thomas A. Costello,et al.  A Fan-Actuated Mechanism for Controlled Exposure of a Psychrometer Wet Bulb Sensor to a Dusty Environment , 1991 .

[26]  W. Xiulan A MULTIPOINT VENTILATED PSYCHROMETER AND ITS APPLICATION FOR PROTECTED CULTIVATION , 1988 .

[27]  Yasuo Nantou,et al.  Digital Ventilated Psychrometer , 1979, IEEE Transactions on Instrumentation and Measurement.

[28]  T. W. Putnam,et al.  Equations for the determination of humidity from dewpoint and psychrometric data , 1977 .

[29]  R. Slatyer,et al.  A Differential Psychrometer for Continuous Measurements of Transpiration. , 1964, Plant physiology.

[30]  Y. Ōmori An Investigation of Psychrometer, II , 1960 .

[31]  Y. Ōmori,et al.  An Investiagtion of Thermocouple Psychrometer, I , 1953 .

[32]  W. Gordon Nomograms for the Conversion of Psychrometric Data into Expressions of Vapor Pressure, Dew Point, Relative Humidity, or Vapor Pressure Deficit , 1940 .

[33]  R W Powell,et al.  The use of thermocouples for psychrometric purposes , 1936 .