Comparison of Three Methods for Field Measurement of Solute Leaching in a Sandy Soil

To identify the most suitable technique for measuring solute leaching in a sandy soil, we compared three methods in an irrigation experiment (irrigation rates: 5 and 2.4 mm h -1 ) using Cl - as a tracer. We tested tensiometer-controlled suction plates, wick samplers, and ionexchange resin boxes installed between fiberglass pads. Ten samplers of each type were installed at a 52-cm depth (suction plates) or a 60-cm depth (wick and resin box samplers) into soil monoliths. The recovery of water and Cl - by the suction plates varied little with irrigation rate (107-118%). The wick samplers performed well during 5 mm h -1 irrigation (Cl - recovery: 111%; water recovery: 103%). However, at the irrigation rate of 2.4 mm h -1 , the water recovery was significantly lower (70%), probably because the soil suction exceeded the maximum capillary force of the wicks. The wicks did not induce a retardation or additional dispersion of Cl - compared with suction plates. The recovery of Cl - by the resin boxes was only 6%. Tensiometer-controlled suction plates allowed an overall satisfactory estimation of water and solute fluxes in the sandy soil.

[1]  J. Siemens,et al.  Dissolved organic carbon is released from sealings and glues of pore-water samplers , 2003 .

[2]  R. H. Fox,et al.  Leachate Collection Efficiency of Zero‐tension Pan and Passive Capillary Fiberglass Wick Lysimeters , 2002 .

[3]  Klaus Kaiser,et al.  Exchange resin cores for the estimation of nutrient fluxes in highly permeable tropical soil , 2001 .

[4]  John S. Selker,et al.  Field evaluation of passive capillary samplers for estimating groundwater recharge , 2000 .

[5]  S. T. Gower,et al.  An Equilibrium Tension Lysimeter for Measuring Drainage through Soil , 1999 .

[6]  M. Kaupenjohann,et al.  Stoffeintrag ins Grundwasser : Feldmethodenvergleich unter Berücksichtigung von preferential flow , 1999 .

[7]  M. Vanclooster,et al.  Effects of soil type and water flux on solute transport , 1997 .

[8]  J. Selker,et al.  Field Evaluation of Passive Capillary Samplers , 1996 .

[9]  J. Selker,et al.  Fiberglass wick sampler effects on measurements of solute transport in the vadose zone , 1996 .

[10]  T. Steenhuis,et al.  One‐Dimensional Model to Evaluate the Performance of Wick Samplers in Soils , 1995 .

[11]  J. Selker,et al.  Unsaturated hydraulic conductivities of fiberglass wicks and designing capillary wick pore-water samplers , 1994 .

[12]  Tammo S. Steenhuis,et al.  Fiberglass wicks for sampling of water and solutes in the vadose zone , 1992 .

[13]  W. Jury,et al.  Interpretation of Solute Transport Data Obtained with Fiberglass Wick Soil Solution Samplers , 1992 .

[14]  K. Brown,et al.  Capillary‐Wick Unsaturated Zone Soil Pore Water Sampler , 1991 .

[15]  C. Dirksen,et al.  Automated in situ measurement of unsaturated soil water flux. , 1988 .

[16]  R. Schnabel Measuring Nitrogen Leaching with Ion Exchange Resin: A Laboratory Assessment1 , 1983 .