Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor.

Surface plasmon resonance (SPR) biosensors offer the capability for continuous real-time monitoring. The commercial instruments available have been large in size, expensive, and not amenable to field applications. We report here an SPR sensor system based on a prototype two-channel system similar to the single channel Spreeta devices. This system is an ideal candidate for field use. The two-channel design provides a reference channel to compensate for bulk refractive index (RI), non-specific binding and temperature variations. The SPR software includes a calibration function that normalizes the response from both channels, thus enabling accurate referencing. In addition, a temperature-controlled enclosure utilizing a thermo-electric module based on the Peltier effect provides the temperature stability necessary for accurate measurements of RI. The complete SPR sensor system can be powered by a 12V battery. Pre-functionalized, disposable, gold-coated thin glass slides provide easily renewable sensor elements for the system. Staphylococcus aureus enterotoxin B (SEB), a small protein toxin was directly detectable at sub-nanomolar levels and with amplification at femtomolar levels. A regeneration procedure for the sensor surface allowed for over 60 direct detection cycles in a 1-month period.

[1]  A. Campagnari,et al.  Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence. , 2000, Biosensors & bioelectronics.

[2]  T J Cieslak,et al.  Clinical recognition and management of patients exposed to biological warfare agents. , 1997, Clinics in laboratory medicine.

[3]  H. Yu,et al.  Comparative studies of magnetic particle-based solid phase fluorogenic and electrochemiluminescent immunoassay. , 1998, Journal of immunological methods.

[4]  M. Natan,et al.  Colloidal Au-enhanced surface plasmon resonance immunosensing. , 1998, Analytical chemistry.

[5]  W. Lukosz,et al.  Integrated-optical and surface-plasmon sensors for direct affinity sensing. Part II: Anisotropy of adsorbed or bound protein adlayers , 1997 .

[6]  S. Yee,et al.  A fiber-optic chemical sensor based on surface plasmon resonance , 1993 .

[7]  T J Cieslak,et al.  Biological warfare : A historical perspective , 1997 .

[8]  B M Paddle,et al.  Biosensors for chemical and biological agents of defence interest. , 1996, Biosensors & bioelectronics.

[9]  Ryozo Nagai,et al.  Sarin poisoning in Tokyo subway , 1995, The Lancet.

[10]  H. Yu Enhancing immunoelectrochemiluminescence (IECL) for sensitive bacterial detection. , 1996, Journal of immunological methods.

[11]  Naoki Masuda,et al.  Sarin poisoning in Tokyo subway , 1995, The Lancet.

[12]  B. Liedberg,et al.  Principles of biosensing with an extended coupling matrix and surface plasmon resonance , 1993 .

[13]  Ki-Bong Choi,et al.  Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin , 1998 .

[14]  C. Taylor,et al.  Regeneration of immunosorbent surfaces used in clinical, industrial and environmental biosensors. Role of covalent and non-covalent interactions. , 1990, Journal of immunological methods.

[15]  C. Jung,et al.  Development of a surface plasmon resonance sensor for commercial applications , 1997 .

[16]  Charles T. Campbell,et al.  Novel approach to multichannel SPR sensing , 1999, Optics East.

[17]  Pierce,et al.  Raman scattering and attenuated-total-reflection studies of surface-plasmon polaritons. , 1986, Physical review. B, Condensed matter.

[18]  C. Fullerton,et al.  The threat of biological weapons. Prophylaxis and mitigation of psychological and social consequences. , 1997, JAMA.

[19]  L M Tender,et al.  Array biosensor for simultaneous identification of bacterial, viral, and protein analytes. , 1999, Analytical chemistry.

[20]  F. Ligler,et al.  Detection of multiple toxic agents using a planar array immunosensor. , 1998, Biosensors & bioelectronics.

[21]  J. Gergely,et al.  Zero-length crosslinking procedure with the use of active esters. , 1990, Analytical biochemistry.

[22]  Chris A. Rowe-Taitt,et al.  Array biosensor for detection of biohazards. , 2000, Biosensors & bioelectronics.

[23]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[24]  T. Chinowsky Optical multisensors based on surface plasmon resonance , 2000 .

[25]  A A Boiarski,et al.  The development of immunoassays to four biological threat agents in a bidiffractive grating biosensor. , 2000, Biosensors & bioelectronics.

[26]  R. Zilinskas,et al.  Iraq's biological weapons. The past as future? , 1997, JAMA.

[27]  Rapid identification of biological warfare agents using an instrument employing a light addressable potentiometric sensor and a flow-through immunofiltration-enzyme assay system. , 2000, Biosensors & bioelectronics.

[28]  T. Chinowsky,et al.  Quantitative interpretation of the response of surface plasmon resonance sensors to adsorbed films , 1998 .

[29]  G. Anderson,et al.  Multi-analyte interrogation using the fiber optic biosensor. , 2000, Biosensors & bioelectronics.

[30]  S M Gendel,et al.  Impedance based sensing of the specific binding reaction between Staphylococcus enterotoxin B and its antibody on an ultra-thin platinum film. , 1995, Biosensors & bioelectronics.

[31]  T. L. Dibrova,et al.  Development of the myoglobin sensor based on the surface plasmon resonance. , 1999, Ukrains'kyi biokhimichnyi zhurnal.

[32]  R. W. Wright,et al.  Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactions. , 1986, Analytical biochemistry.

[33]  J. Hall,et al.  Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor. , 2000, Biosensors & bioelectronics.

[34]  J J Valdes,et al.  Recombinant antibodies: a new reagent for biological agent detection. , 2000, Biosensors & bioelectronics.

[35]  S Koch,et al.  Optical flow-cell multichannel immunosensor for the detection of biological warfare agents. , 2000, Biosensors & bioelectronics.

[36]  N. F. Starodub,et al.  Construction and biomedical application of immunosensors based on fiber optics and enhanced chemiluminescence , 1994 .

[37]  J. Clendenning,et al.  Construction of biosensors using a gold-binding polypeptide and a miniature integrated surface plasmon resonance sensor. , 1998, Biosensors & bioelectronics.

[38]  H. Ahmed,et al.  Development of a magnetic microplate chemifluorimmunoassay for rapid detection of bacteria and toxin in blood. , 1998, Analytical biochemistry.

[39]  Dwight U. Bartholomew,et al.  Integrated analytical sensors: the use of the TISPR-1 as a biosensor , 1999 .

[40]  Clement E. Furlong,et al.  A commercial solution for surface plasmon sensing , 1996 .