A New Device for High-Speed Biaxial Tissue Testing: Application to Traumatic Rupture of the Aorta

A biaxial test device was designed to obtain the material properties of aortic tissue at rates consistent with those seen in automotive impact. Fundamental to the design are four small tissue clamps used to grasp the ends of the tissue sample. The applied load at each clamp is determined using subminiature load cells in conjunction with miniature accelerometers for inertial compensation. Four lightweight carriages serve as mounting points for each clamp. The carriages ride on linear shafts, and are equipped with low-friction bearings. Each carriage is connected to the top of a central drive disk by a rigid link. A fifth carriage, also connected to the drive disk by a rigid link, is attached at the bottom. A pneumatic cylinder attached to the lower carriage initiates rotation of the disk. This produces identical motion of the upper carriages in four directions away from the disk center. Initial slack in a low-stretch, high-strength rope that connects the cylinder to the lower carriage allows the cylinder to achieve the desired test speed before initiating motion in the carriages. Two lasers, focused on the top and bottom surfaces of the tissue samples measure sample thickness throughout a given test.

[1]  D. Bergel,et al.  The dynamic elastic properties of the arterial wall , 1961, The Journal of physiology.

[2]  T A Wilson,et al.  Biaxial constitutive relations for the passive canine diaphragm. , 2000, Journal of applied physiology.

[3]  M. Sacks,et al.  Biaxial mechanical properties of passive right ventricular free wall myocardium. , 1992, Journal of biomechanical engineering.

[4]  R Collins,et al.  Dynamic deformation experiments on aortic tissue. , 1972, Journal of biomechanics.

[5]  F. Yin,et al.  Passive biaxial mechanical properties of isolated canine myocardium. , 1983, The Journal of physiology.

[6]  K Darvish,et al.  Material properties for modeling traumatic aortic rupture. , 2001, Stapp car crash journal.

[7]  Y C Fung,et al.  The degree of nonlinearity and anisotropy of blood vessel elasticity. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[8]  J W Melvin,et al.  Failure properties of passive human aortic tissue. II--Biaxial tension tests. , 1983, Journal of biomechanics.

[9]  I. C. Benson,et al.  STUDIES ON THE ELASTIC PROPERTIES OF HUMAN ISOLATED AORTA. , 1937, The Journal of clinical investigation.

[10]  F H Silver,et al.  Mechanical properties of the aorta: a review. , 1989, Critical reviews in biomedical engineering.

[11]  David C. Viano,et al.  Biomechanics of nonpenetrating aortic trauma: a review , 1983 .

[12]  J. Lundervall,et al.  THE MECHANISM OF TRAUMATIC RUPTURE OF THE AORTA. , 1964, Acta pathologica et microbiologica Scandinavica.

[13]  S. Waldman,et al.  Boundary conditions during biaxial testing of planar connective tissues. Part 1: Dynamic Behavior , 2002, Journal of materials science. Materials in medicine.

[14]  S D Waldman,et al.  Imposed state of deformation determines local collagen fibre orientation but not apparent mechanical properties. , 1999, Biomedical sciences instrumentation.

[15]  D. Bergel The static elastic properties of the arterial wall , 1961, The Journal of physiology.

[16]  B H Smaill,et al.  Biaxial testing of membrane biomaterials: testing equipment and procedures. , 1991, Journal of biomechanical engineering.

[17]  B. S. Gow,et al.  Measurement of Viscoelastic Properties of Arteries in the Living Dog , 1968, Circulation research.

[18]  J W Melvin,et al.  Failure properties of passive human aortic tissue. I--uniaxial tension tests. , 1982, Journal of biomechanics.

[19]  M. Sacks Biaxial Mechanical Evaluation of Planar Biological Materials , 2000 .

[20]  K H Yang,et al.  Development of a computer model to predict aortic rupture due to impact loading. , 2001, Stapp car crash journal.