Passive mixing in a three-dimensional serpentine microchannel

A three-dimensional serpentine microchannel design with a "C shaped" repeating unit is presented in this paper as a means of implementing chaotic advection to passively enhance fluid mixing. The device is fabricated in a silicon wafer using a double-sided KOH wet-etching technique to realize a three-dimensional channel geometry. Experiments using phenolphthalein and sodium hydroxide solutions demonstrate the ability of flow in this channel to mix faster and more uniformly than either pure molecular diffusion or flow in a "square-wave" channel for Reynolds numbers from 6 to 70. The mixing capability of the channel increases with increasing Reynolds number. At least 98% of the maximum intensity of reacted phenolphthalein is observed in the channel after five mixing segments for Reynolds numbers greater than 25. At a Reynolds number of 70, the serpentine channel produces 16 times more reacted phenolphthalein than a straight channel and 1.6 times more than the square-wave channel. Mixing rates in the serpentine channel at the higher Reynolds numbers are consistent with the occurrence of chaotic advection. Visualization of the interface formed in the channel between streams of water and ethyl alcohol indicates that the mixing is due to both diffusion and fluid stirring.

[1]  E. Caldin Fast reactions in solution , 1964 .

[2]  R. Breidenthal,et al.  Structure in turbulent mixing layers and wakes using a chemical reaction , 1981, Journal of Fluid Mechanics.

[3]  H. Aref Stirring by chaotic advection , 1984, Journal of Fluid Mechanics.

[4]  D. Leckband,et al.  Interactions between nucleotide binding sites on chloroplast coupling factor during ATP hydrolysis. , 1987, Biochemistry.

[5]  Hassan Aref,et al.  Chaotic advection by laminar flow in a twisted pipe , 1989, Journal of Fluid Mechanics.

[6]  H. Aref Chaotic advection of fluid particles , 1990, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences.

[7]  Willy Sansen,et al.  Compensation structures for convex corner micromachining in silicon , 1990 .

[8]  R.M. White,et al.  Ultrasonically induced microtransport , 1991, [1991] Proceedings. IEEE Micro Electro Mechanical Systems.

[9]  Mihir Sen,et al.  Heat transfer enhancement in coiled tubes by chaotic mixing , 1992 .

[10]  R. Miyake,et al.  Micro mixer with fast diffusion , 1993, [1993] Proceedings IEEE Micro Electro Mechanical Systems.

[11]  Steven P. Schneider,et al.  Quantitative molecular-mixing measurements using digital processing of absorption images , 1995 .

[12]  Jens Anders Branebjerg,et al.  Application of Miniature Analyzers: from Microfluidic Components to µTAS , 1995 .

[13]  W. Ehrfeld,et al.  Microreactor with Integrated Static Mixer and Analysis System , 1995 .

[14]  Jens Anders Branebjerg,et al.  Fast mixing by lamination , 1996, Proceedings of Ninth International Workshop on Micro Electromechanical Systems.

[15]  Hsueh-Chia Chang,et al.  Effect of chaotic interfacial stretching on bimolecular chemical reaction in helical-coil reactors , 1996 .

[16]  D. J. Harrison,et al.  Microfluidic systems for clinical diagnostics , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[17]  Hassan Peerhossaini,et al.  The effects of chaotic advection on heat transfer , 1997 .

[18]  Y. Tai,et al.  Microfluidic sub-millisecond mixers for the study of chemical reaction kinetics , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[19]  Harold T. Evensen,et al.  Automated fluid mixing in glass capillaries , 1998 .

[20]  R. Anderson,et al.  Genetic Anaylsis Systems: Improvements and Methods , 1998 .

[21]  Integrated Gas Phase Microreactors , 1998 .

[22]  Chaotic advection in a static microscale mixer , 1998 .

[23]  Joel Voldman,et al.  Liquid Mixing Studies with an Integrated Mixer/Valve , 1998 .

[24]  Miniaturization Puts Chemical Plants Where You Want Them , 1998, Science.

[25]  A Microanalytical Device for the Assessment of Coagulation Parameters in Whole Blood , 1998 .

[26]  David J. Beebe,et al.  Fabrication of three-dimensional microfluidic systems by stacking molded polydimethylsiloxane (PDMS) layers , 1999, MOEMS-MEMS.

[27]  Dorian Liepmann,et al.  PLANAR LAMINAR MIXER , 2000 .